OSHA SearchOSHA records by employer

Jones Electric Company: OSHA inspections and violations

Muskegon, Michigan · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · NAICS 811310

1inspections
29citation items
$5,850current penalties
Mar 19, 2026last inspection

OSHA has inspected Jones Electric Company once in Michigan.

The inspection began on Mar 19, 2026 as a planned inspection, in Muskegon.

That inspection ended with 29 citation items: 25 serious and 4 other-than-serious.

Penalties were first proposed at $11,700 and now stand at $5,850, 50% lower after settlements or reviews.

Lockout/tagout comes up most often in these citations: 5 items under 1910.147.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Jones Electric Company averages $5,850 (1 cited inspection).

Jones Electric Company: OSHA citation items per year, 2026 to 2026
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

641employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch Jones Electric Company and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348820861 OPENED MAR 19, 2026Closed

Planned · Complete · Safety · 9 employees at the site · Closed Jun 23, 2026

1965 Sanford St, Muskegon, MI 49441 · Commercial and Industrial Machinery and Equipment (except Automotive and Electronic) Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 408.10034(3)
Serious$400$200May 19, 2026Final
Citation 1, item 1b
29 CFR 408.10034(10)
Serious$0$0May 19, 2026Final
Citation 1, item 2
29 CFR 408.10121(1)
Serious$400$200May 19, 2026Final
Citation 1, item 3a
29 CFR 408.10727(1)
Serious$400$200May 19, 2026Final
Citation 1, item 3b
29 CFR 408.10731(1)
Serious$0$0May 19, 2026Final
Citation 1, item 4
29 CFR 408.11115(4)
Serious$400$200May 19, 2026Final
Citation 1, item 5
29 CFR 408.12648(1)
Serious$400$200May 19, 2026Final
Citation 1, item 6
29 CFR 408.12635(2)
Serious$400$200May 19, 2026Final
Citation 1, item 7
29 CFR 408.13308(1)
Serious$2,100$1,050May 19, 2026Final
Citation 1, item 8a
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$400$200May 19, 2026Final
Citation 1, item 8b
29 CFR 1910.305(j)(1)(iv) · Electrical wiring methods
Serious$0$0May 19, 2026Final
Citation 1, item 9a
29 CFR 408.14923(1)
Serious$2,100$1,050May 19, 2026Final
Citation 1, item 9b
29 CFR 408.14926(2)
Serious$0$0May 19, 2026Final
Citation 1, item 10a
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$500$250May 19, 2026Final
Citation 1, item 10b
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0May 19, 2026Final
Citation 1, item 11a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$2,100$1,050May 19, 2026Final
Citation 1, item 11b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0May 19, 2026Final
Citation 1, item 11c
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0May 19, 2026Final
Citation 1, item 11d
29 CFR 1910.147(d)(6) · Lockout/tagout
Serious$0$0May 19, 2026Final
Citation 1, item 11e Serious$0$0May 19, 2026Final
Citation 1, item 12a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,100$1,050May 19, 2026Final
Citation 1, item 12b
29 CFR 1910.1200(g)(8) · Hazard communication
Serious$0$0May 19, 2026Final
Citation 1, item 12c
29 CFR 1910.1200(f)(6) · Hazard communication
Serious$0$0May 19, 2026Final
Citation 1, item 12d
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0May 19, 2026Final
Citation 1, item 12e
29 CFR 325.47201(3)
Serious$0$0May 19, 2026Final
Citation 2, item 1
29 CFR 408.12154(5)
Other-than-serious$0$0May 19, 2026Final
Citation 2, item 2
29 CFR 408.13308(3)
Other-than-serious$0$0May 19, 2026Final
Citation 2, item 3a
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Other-than-serious$0$0May 19, 2026Final
Citation 2, item 3b
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$0$0May 19, 2026Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(2)

(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.

29 CFR 1910.107(g)(2)

(2) Cleaning. All spraying areas shall be kept as free from the accumulation of deposits of combustible residues as practical, with cleaning conducted daily if necessary. Scrapers, spuds, or other such tools used for cleaning purposes shall be of nonsparking material.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other commercial and industrial machinery and equipment (except automotive and electronic) repair and maintenance employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.