OSHA inspectors have visited Advantek Waste Management Services LLC in Texas one time.
It opened on Oct 30, 2017 on a referral, in Kenedy.
In all, OSHA issued 4 citation items: 4 other-than-serious.
The proposed penalties came to $36,216; today they stand at $25,000, 31% less.
The rule cited most here is 1910.132 (personal protective equipment, general requirements), 2 times.
Among mining and oil and gas employers, the typical cited inspection since 2015 ends with a $2,883 penalty. Advantek Waste Management Services LLC averages $25,000 across 1 cited inspection.
It reported 3 severe injuries to OSHA since 2015.
Inspection 342738275 OPENED OCT 30, 2017Closed
Referral · Partial · Health · 22 employees at the site · Closed May 10, 2018
540 Fm 2985, Kenedy, TX 78119 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps
Incident on Oct 23, 2017: Employee is struck by flash arc and suffers first degree bur
At 8:00 p.m. on October 23, 2017, an employee was standing at a shaker table and washing off with a water pump. The employee suffered first degree burns to his face and right hand when he was struck by a flash arc. The employee was hospitalized.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|
| Citation 1, item 1 |
Other-than-serious | $9,054 | $6,250 | Feb 21, 2018 | Final |
| Citation 1, item 2 |
Other-than-serious | $9,054 | $6,250 | Feb 21, 2018 | Final |
| Citation 1, item 3 |
Other-than-serious | $9,054 | $6,250 | Feb 21, 2018 | Final |
| Citation 1, item 4 |
Other-than-serious | $9,054 | $6,250 | Feb 21, 2018 | Final |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.
Nov 14, 2018, Kenedy: Hospitalization · heat (thermal) burns, unspecified · multiple body parts, n.e.c.
An employee was operating a front-end loader to push flowback solids into the solids bay when fumes from a liquid were ignited causing a flash fire and burning the employee's face and the backside of a hand.
Oct 23, 2017, Kenedy: Hospitalization · electrical burns, unspecified · face, unspecified
An employee was working at a shaker table to properly dispose of oil and gas drilling waste when a water pump created an arc flash that burned the employee's face.
Aug 27, 2015, Kenedy: Hospitalization · fractures · ankle(s)
An employee fell approximately 10 feet while setting straps on a storage tank and landed on his feet. He suffered injuries to both feet and a broken right ankle.