OSHA SearchOSHA records by employer

AG Construction, Inc.: OSHA inspections and violations

El Paso, Texas · Drywall and Insulation Contractors · NAICS 238310

4inspections
16citation items
$13,239current penalties
Mar 18, 2019last inspection

Since 2000, OSHA inspectors have visited AG Construction, Inc. in Texas 4 times.

The most recent inspection opened on Mar 18, 2019 as a planned inspection, in Spring.

In all, OSHA issued 16 citation items: 10 serious, 5 repeat and 1 other-than-serious.

The proposed penalties came to $15,689; today they stand at $13,239, 16% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 13 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,079 penalty. AG Construction, Inc. averages $3,789 across 1 cited inspection.

AG Construction, Inc.: OSHA citation items per year, 2000 to 2019
Citation items per year, by inspection date.

Want to know if OSHA cites AG Construction, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 343857827 OPENED MAR 18, 2019Closed

Planned · Partial · Safety · 11 employees at the site · Closed Mar 3, 2026

25825 Aldine Westfield Rd., Spring, TX 77373 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.453(b)(2)(v) · Aerial lifts
Serious$3,789$3,789Mar 25, 2019Final

Inspection 307266692 OPENED OCT 13, 2009Closed

Planned · Complete · Safety · 10 employees at the site · Closed Apr 12, 2012

Transmountain And Highway 54, El Paso, TX 79927 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$600$600Oct 20, 2009Closed
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$450$450Oct 20, 2009Closed
Citation 1, item 3
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$600$600Oct 20, 2009Closed
Citation 2, item 1
29 CFR 1926.454(a) · Scaffold training
Other-than-serious$0$0Oct 20, 2009Closed

Inspection 301571600 OPENED AUG 28, 2001Closed

Planned · Complete · Safety · 8 employees at the site · Closed Dec 5, 2003

8855 Viscount, El Paso, TX 79903 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Repeat$2,000$2,000Nov 28, 2001Closed
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Repeat$2,000$2,000Nov 28, 2001Closed
Citation 1, item 2b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Repeat$0$0Nov 28, 2001Closed
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Repeat$1,200$1,200Nov 28, 2001Closed
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Repeat$1,600$1,600Nov 28, 2001Closed

Inspection 301569620 OPENED JUN 1, 2000Closed

Planned · Partial · Safety · 3 employees at the site · Closed Oct 12, 2000

10090 Northloop, El Paso, TX 79927 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(b)(1) · Scaffolds, general requirements
Serious$750$200Aug 2, 2000Closed
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$750$200Aug 2, 2000Closed
Citation 1, item 2b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Aug 2, 2000Closed
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$450$200Aug 2, 2000Closed
Citation 1, item 4
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,050$200Aug 2, 2000Closed
Citation 1, item 5
29 CFR 1926.454(a) · Scaffold training
Serious$450$200Aug 2, 2000Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)

(b) Scaffold platform construction. (1) Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports as follows:

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.453 · Aerial lifts

29 CFR 1926.454 · Scaffold training

Other drywall and insulation contractors employers in Texas