OSHA SearchOSHA records by employer

Aghorn Operating, Inc.: OSHA inspections and violations

Odessa, Texas · Support Activities for Oil and Gas Operations · NAICS 213112

2inspections
5citation items
$75,000current penalties
Nov 4, 2021last inspection

Aghorn Operating, Inc. has 2 OSHA inspections on record in Texas, the first in 2019.

OSHA's last visit started on Nov 4, 2021 to follow up on an earlier case, in Odessa.

Across those inspections OSHA issued 5 citation items: 5 serious.

OSHA proposed $105,253 in penalties. After settlements and reviews the total is $75,000, down 29%.

Most often, OSHA cited 1910.134, respiratory protection (2 items).

For context, across all mining and oil and gas employers the median penalty per cited inspection since 2015 is $2,880. Aghorn Operating, Inc. averages $75,000 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

Aghorn Operating, Inc. also files yearly injury logs with OSHA, summarized below.

Aghorn Operating, Inc.: OSHA citation items per year, 2019 to 2021
Citation items per year, by inspection date.

Want to know if OSHA cites Aghorn Operating, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 345618979 OPENED NOV 4, 2021Closed

Follow-up · Partial · Health · 23 employees at the site · Closed Nov 19, 2021

2200 W. 49th Street, Odessa, TX 79763 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344408901 OPENED OCT 26, 2019Closed

Fatality or catastrophe · Partial · Health · 26 employees at the site · Closed Sep 29, 2021

2216 W. 49th Street, Odessa, TX 79763 · Support Activities for Oil and Gas Operations · OSHA's record · Phone and website on Google Maps

Incident on Oct 26, 2019 (fatal): Employee is overcome and suffocates from hydrogen sulfide ga

AT 7:00 p.m. on October 26, 2019, an employee entered the pump house to investigate an alarm. The employee was overcome by hydrogen sulfide gas when Pump #1 produced water containing hydrogen sulfide and contaminated the atmosphere. The employee died from asphyxiation.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$9,446$6,000Apr 23, 2020Final
Citation 1, item 2
29 CFR 1910.134(d)(1)(ii) · Respiratory protection
Serious$9,446$6,000Apr 23, 2020Final
Citation 1, item 3
29 CFR 1910.1000(e) · Air contaminants
Serious$9,446$6,000Apr 23, 2020Final
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$9,446$6,000Apr 23, 2020Final
Citation 2, item 1
29 CFR 1910.1000(b)(2) · Air contaminants
Serious$67,469$51,000Apr 23, 2020Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2022, the Odessa site logged 1 recordable injury or illness among about 25 workers: 3.8 per 100 full-time workers, against a median of 0.0 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Aghorn Operating
Odessa · 2022
25 103.80.0

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(b)(2)

(2) Acceptable ceiling concentrations. An employee's exposure to a substance listed in Table Z-2 shall not exceed at any time during an 8-hour shift the acceptable ceiling concentration limit given for the substance in the table, except for a time period, and up to a concentration not exceeding the maximum duration and concentration allowed in the column under “acceptable maximum peak above the acceptable ceiling concentration for an 8-hour shift.”

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.134 · Respiratory protection

Other support activities for oil and gas operations employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.