OSHA SearchOSHA records by employer

Airborn, Inc.: OSHA inspections and violations

Georgetown, Texas · Other Electronic Parts and Equipment Merchant Wholesalers · NAICS 423690

12inspections
45citation items
$12,402current penalties
Sep 17, 2020last inspection

OSHA has inspected Airborn, Inc. 12 times in Texas since 1975.

The latest one began on Sep 17, 2020 to monitor an earlier case, in Georgetown.

Those inspections ended with 45 citation items: 23 serious, 2 repeat and 20 other-than-serious.

Penalties were first proposed at $41,900 and now stand at $12,402, 70% lower after settlements or reviews.

Hazard communication comes up most often in these citations: 8 items under 1910.1200.

How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,425, and Airborn, Inc. averages $600 (1 cited inspection).

Airborn, Inc. also files yearly injury logs with OSHA, summarized below.

It reported 1 severe injury to OSHA since 2015.

Airborn, Inc.: OSHA citation items per year, 1975 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites Airborn, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344934617 OPENED SEP 17, 2020Closed

Monitoring · Partial · Safety · 653 employees at the site · Closed Sep 25, 2020

3500 Airborn Circle, Georgetown, TX 78626 · Other Electronic Parts and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 344757810 OPENED MAY 20, 2020Closed

Other · Partial · Safety · 630 employees at the site · Closed Jun 9, 2020

3500 Airborn Circle, Georgetown, TX 78626 · Other Electronic Parts and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$1,000$600May 22, 2020Final

Inspection 312855778 OPENED FEB 9, 2010Closed

Complaint · Partial · Health · 400 employees at the site · Closed Mar 1, 2010

215 Royal Drive, Georgetown, TX 78626 · Power, Distribution, and Specialty Transformer Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Serious$1,125$675Feb 19, 2010Closed

Inspection 300430998 OPENED APR 2, 1997Closed

Complaint · Partial · Safety · 260 employees at the site · Closed Apr 30, 1998

215 Royal Drive, Georgetown, TX 78627 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(q)(1) · Exit routes
Serious$2,000$1,200Jul 28, 1997Closed
Citation 1, item 2
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$1,500$900Jul 28, 1997Closed
Citation 1, item 3a
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$1,500$900Jul 28, 1997Closed
Citation 1, item 3b
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Serious$0$0Jul 28, 1997Closed
Citation 1, item 3c
29 CFR 1910.147(f)(3)(i) · Lockout/tagout
Serious$0$0Jul 28, 1997Closed
Citation 1, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Serious$2,000$1,200Jul 28, 1997Closed
Citation 1, item 5
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,500$900Jul 28, 1997Closed
Citation 1, item 6
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$2,000$1,200Jul 28, 1997Closed
Citation 2, item 1
29 CFR 1910.37(k)(2) · Exit routes
Repeat$15,000$1,000Jul 28, 1997Closed
Citation 2, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Repeat$200$120Jul 28, 1997Closed

Inspection 123477804 OPENED MAR 19, 1996Closed

Complaint · No inspection · Health · 260 employees at the site · Closed Mar 19, 1996

215 Royal Drive, Georgetown, TX 78627 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 123548836 OPENED NOV 15, 1994Closed

Complaint · Partial · Health · 260 employees at the site · Closed Oct 12, 1995

215 Royal Drive, Georgetown, TX 78627 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(k)(2) · Exit routes
Other-than-serious$1,125$0Jan 27, 1995Closed
Citation 1, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$1,125$0Jan 27, 1995Closed
Citation 1, item 3a
29 CFR 1910.134(a)(2) · Respiratory protection
Serious$4,500$1,875Jan 27, 1995Closed
Citation 1, item 3b
29 CFR 1910.134(b)(1) · Respiratory protection
Serious$0$0Jan 27, 1995Closed
Citation 1, item 3c
29 CFR 1910.1000(b)(1) · Air contaminants
Serious$0$0Jan 27, 1995Closed
Citation 1, item 3d
29 CFR 1910.1000(b)(2) · Air contaminants
Serious$0$0Jan 27, 1995Closed
Citation 1, item 3e
29 CFR 1910.1000(b)(2) · Air contaminants
Serious$0$0Jan 27, 1995Closed
Citation 1, item 3f
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Jan 27, 1995Closed
Citation 1, item 4
29 CFR 1910.212(a)(5) · Machine guarding
Other-than-serious$1,125$0Jan 27, 1995Closed
Citation 1, item 5a
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Serious$2,625$1,312Jan 27, 1995Closed
Citation 1, item 5b
29 CFR 1910.1200(f)(5)(ii) · Hazard communication
Serious$0$0Jan 27, 1995Closed
Citation 1, item 6
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$2,625$0Jan 27, 1995Closed
Citation 2, item 1 Other-than-serious$0$0Jan 27, 1995Closed
Citation 2, item 2
29 CFR 1910.1200(e)(1)(ii) · Hazard communication
Other-than-serious$0$0Jan 27, 1995Closed
Citation 2, item 3
29 CFR 1910.1200(e)(2)(i) · Hazard communication
Other-than-serious$0$0Jan 27, 1995Closed

Inspection 106799844 OPENED MAY 9, 1990Closed

Complaint · Partial · Health · 29 employees at the site · Closed Sep 20, 1990

Fm 312 South, Winnsboro, TX 75494 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$280$140Aug 3, 1990Closed
Citation 1, item 1b
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$0$0Aug 3, 1990Closed
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$160$80Aug 3, 1990Closed
Citation 1, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$210$105Aug 3, 1990Closed
Citation 1, item 4
29 CFR 1910.1200(h) · Hazard communication
Serious$210$105Aug 3, 1990Closed
Citation 2, item 1
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 3, 1990Closed
Citation 2, item 2
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Aug 3, 1990Closed

Inspection 101430254 OPENED OCT 17, 1988Closed

Accident · Partial · Health · 315 employees at the site · Closed Dec 12, 1988

4321 Airborn Drive, Addison, TX 75001 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

4 older inspections

Inspection 16549396 OPENED MAR 13, 1979Closed

Planned · Complete · Safety · 230 employees at the site · Closed Aug 15, 1979

4321 Airborn Drive, Addison, TX 75001 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Mar 21, 1979Closed
Citation 1, item 2
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 21, 1979Closed
Citation 1, item 3
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0Mar 21, 1979Closed
Citation 1, item 4 Other-than-serious$0$0Mar 21, 1979Closed

Inspection 16503344 OPENED MAY 3, 1978Closed

Complaint · Complete · Health · 230 employees at the site · Closed May 26, 1978

4321 Airborn Drive, Addison, TX 75001 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 16519654 OPENED OCT 10, 1975Closed

Follow-up · Complete · Safety · 150 employees at the site · Closed Mar 10, 1984

4321 Airborn Drive, Addison, TX 75220 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 16519217 OPENED AUG 20, 1975Closed

Planned · Complete · Safety · 150 employees at the site · Closed Oct 28, 1975

4321 Airborn Dr, Addison, TX 75220 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(2) · Flammable liquids
Other-than-serious$0$0Aug 25, 1975Closed
Citation 1, item 2
29 CFR 1910.212(a)(5) · Machine guarding
Other-than-serious$0$0Aug 25, 1975Closed
Citation 1, item 3
29 CFR 1910.213(i)(1) · Woodworking machinery
Other-than-serious$30$30Aug 25, 1975Closed
Citation 1, item 4
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Other-than-serious$30$30Aug 25, 1975Closed
Citation 1, item 5
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$30$30Aug 25, 1975Closed
Citation 1, item 6
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Aug 25, 1975Closed
Citation 1, item 7 Other-than-serious$0$0Aug 25, 1975Closed

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Georgetown site logged 4 recordable injuries or illnesses among about 515 workers: 0.8 per 100 full-time workers, against a median of 0.5 for its industry. Those cases cost 36 days away from work.

Site and yearWorkersCasesDays-away casesRateIndustry median
Airborn, Inc
Georgetown · 2025
515 410.80.5
Airborn Inc. Addison
Addison · 2023
180 000.00.5
Airborn Winnsboro
Winnsboro · 2023
38 225.90.5
Airborn, Inc. (Georgetown)
Georgetown · 2021
561 411.00.5
AirBorn Addison
Addison · 2018
185 000.00.5
Georgetown site
Georgetown · 2017
516 421.10.3

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

May 14, 2020, Georgetown: Hospitalization, amputation · amputations · fingertip(s)

An employee was using a cable-cutting machine to cut wires. The wires got caught inside the machine, and the employee was trying to get them unstuck when the machine cycled and amputated the employee's middle and index fingertips. The machine was unguarded at the time.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(b)(1)

(1) 8-hour time weighted averages. An employee's exposure to any substance listed in Table Z-2, in any 8-hour work shift of a 40-hour work week, shall not exceed the 8-hour time weighted average limit given for that substance in Table Z-2.

29 CFR 1910.1000(b)(2)

(2) Acceptable ceiling concentrations. An employee's exposure to a substance listed in Table Z-2 shall not exceed at any time during an 8-hour shift the acceptable ceiling concentration limit given for the substance in the table, except for a time period, and up to a concentration not exceeding the maximum duration and concentration allowed in the column under “acceptable maximum peak above the acceptable ceiling concentration for an 8-hour shift.”

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.309

29 CFR 1910.37 · Exit routes

Other other electronic parts and equipment merchant wholesalers employers in Texas