OSHA SearchOSHA records by employer

Aisin USA Manufacturing: OSHA inspections and violations

Seymour, Indiana · Other Motor Vehicle Parts Manufacturing · NAICS 336399

12inspections
43citation items
$22,256current penalties
Aug 1, 2025last inspection

Aisin USA Manufacturing has 12 OSHA inspections on record in Indiana, the first in 1990.

OSHA's last visit started on Aug 1, 2025 after a complaint, in Seymour.

Across those inspections OSHA issued 43 citation items: 23 serious, 1 willful and 19 other-than-serious.

OSHA proposed $35,275 in penalties. After settlements and reviews the total is $22,256, down 37%.

Most often, OSHA cited 1910.219, belts, pulleys and power-transmission parts (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Aisin USA Manufacturing averages $2,750 over 3 cited inspections in that time.

Aisin USA Manufacturing: OSHA citation items per year, 1990 to 2025
Citation items per year, by inspection date.

Indiana · latest 90 days of OSHA records

79employers cited

Get notified the morning OSHA posts each new citation in Indiana: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Indiana

Checking a subcontractor, a client or your own company? Watch Aisin USA Manufacturing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348411315 OPENED AUG 1, 2025Closed

Complaint · Partial · Safety · 1,761 employees at the site · Closed Nov 7, 2025

508 Burkart Blvd, Seymour, IN 47274 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 347430605 OPENED APR 23, 2024Closed

Referral · Partial · Safety · 691 employees at the site · Closed Sep 1, 2025

508 Burkart Blvd, Seymour, IN 47274 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 346035850 OPENED JUN 22, 2022Closed

Referral · Partial · Safety · 604 employees at the site · Closed Jan 9, 2024

1700 East 4th Street, Seymour, IN 47274 · Motor Vehicle Metal Stamping · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 22.8(1)(1)(SEC2)
Other-than-serious$5,100$5,100Nov 30, 2022Final
Citation 2, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$0$0Nov 30, 2022Final

Inspection 343157566 OPENED MAR 22, 2018Closed

Complaint · Partial · Health · 2,079 employees at the site · Closed Jun 19, 2018

500 Burkhart Boulevard, Seymour, IN 47274 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Other-than-serious$1,000$650May 31, 2018Final

Inspection 341455715 OPENED MAY 2, 2016Closed

Referral · Partial · Safety · 1,922 employees at the site · Closed Nov 18, 2016

1700 East 4th Street, Seymour, IN 47274 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$5,000$2,500Aug 19, 2016Final

Inspection 308198936 OPENED JAN 25, 2005Closed

Complaint · Partial · Health · 1,923 employees at the site · Closed May 23, 2005

1700 East 4th Street, Seymour, IN 47274 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307895474 OPENED AUG 24, 2004Closed

Planned · Complete · Safety · 1,900 employees at the site · Closed Oct 4, 2004

1700 E 4th Street Rd, Seymour, IN 47274 · Other Motor Vehicle Parts Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$975$634Sep 17, 2004Closed
Citation 1, item 2a Serious$975$634Sep 17, 2004Closed
Citation 1, item 2b Other-than-serious$0$0Sep 17, 2004Closed
Citation 1, item 3
29 CFR 1910.212(a)(1) · Machine guarding
Serious$975$634Sep 17, 2004Closed
Citation 2, item 1
29 CFR 1910.36(b)(4) · Exit route design
Other-than-serious$0$0Sep 17, 2004Closed
Citation 2, item 2
29 CFR 1910.304(a)(2) · Grounding and circuit protection
Other-than-serious$0$0Sep 17, 2004Closed
Citation 2, item 3
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Sep 17, 2004Closed

Inspection 125366104 OPENED JAN 7, 1998Closed

Planned · Complete · Safety · 1,097 employees at the site · Closed Mar 10, 1998

1700 East 4th Street, Seymour, IN 47274 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,050$785Feb 17, 1998Closed
Citation 1, item 3
29 CFR 1910.215(a)(2) · Grinders and abrasive wheels
Serious$1,050$785Feb 17, 1998Closed
Citation 1, item 4
29 CFR 1910.217(c)(3)(viib) · Mechanical power presses
Serious$1,050$785Feb 17, 1998Closed
Citation 2, item 1
29 CFR 1910.36(d)(2) · Exit route design
Other-than-serious$0$0Feb 17, 1998Closed
Citation 2, item 2
29 CFR 1910.106(g)(9) · Flammable liquids
Other-than-serious$0$0Feb 17, 1998Closed
Citation 2, item 3
29 CFR 1910.108(c)(5) · [Reserved]
Other-than-serious$0$0Feb 17, 1998Closed
Citation 2, item 4
29 CFR 1910.151(c) · First aid and eyewash
Other-than-serious$0$0Feb 17, 1998Closed
Citation 2, item 5
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Other-than-serious$0$0Feb 17, 1998Closed
Citation 2, item 7a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Feb 17, 1998Closed
Citation 2, item 7b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Feb 17, 1998Closed
Citation 2, item 8
29 CFR 1910.219(k)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0Feb 17, 1998Closed
Citation 2, item 9
29 CFR 1910.254(b)(4)(iii) · Arc welding and cutting
Other-than-serious$0$0Feb 17, 1998Closed
Citation 2, item 10
29 CFR 1910.303(g)(1)(iv) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 17, 1998Closed
Citation 2, item 11
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Other-than-serious$0$0Feb 17, 1998Closed
4 older inspections

Inspection 125375584 OPENED JAN 25, 1996Closed

Complaint · Partial · Health · 803 employees at the site · Closed Mar 21, 1996

1700 East 4th Street, Seymour, IN 47274 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108619214 OPENED FEB 20, 1992Closed

Complaint · Partial · Health · 578 employees at the site · Closed Mar 18, 1992

1700 East 4th Street, Seymour, IN 47274 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 114963564 OPENED AUG 23, 1991Closed

Accident · Complete · Safety · 550 employees at the site · Closed Nov 22, 1991

1700 East 4th Street, Seymour, IN 47274 · OSHA's record · Phone and website on Google Maps

Incident on Aug 21, 1991: Employee's fingers amputated by press

At approximately 6:10 p.m. on August 21, 1991, Employee #1 was operating an inje ction molding machine that had a hydraulic press. She was operating the machine without the safety guards and using a one-hand control button to cycle the press . While Employee #1 had her right hand in the point of operation, the press cycl ed, catching the fingers on her right hand and amputating them. She was hospital ized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$1,000$500Oct 16, 1991Closed
Citation 1, item 2
29 CFR 1910.23(a)(5) · Guarding floor and wall openings and holes
Serious$600$300Oct 16, 1991Closed
Citation 1, item 3
29 CFR 1910.147(c)(2)(i) · Lockout/tagout
Serious$1,000$500Oct 16, 1991Closed
Citation 1, item 4
29 CFR 1910.147(c)(2)(iii) · Lockout/tagout
Serious$1,000$500Oct 16, 1991Closed
Citation 1, item 5a
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$600$300Oct 16, 1991Closed
Citation 1, item 5b
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Oct 16, 1991Closed
Citation 1, item 6a
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$500$250Oct 16, 1991Closed
Citation 1, item 6b
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Oct 16, 1991Closed
Citation 1, item 7
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$500$250Oct 16, 1991Closed
Citation 1, item 8
29 CFR 1910.254(d)(7) · Arc welding and cutting
Serious$500$250Oct 16, 1991Closed
Citation 1, item 9
29 CFR 1910.254(d)(9)(iii) · Arc welding and cutting
Serious$400$200Oct 16, 1991Closed
Citation 1, item 10
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$600$300Oct 16, 1991Closed
Citation 2, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Willful$10,000$5,000Oct 16, 1991Closed
Citation 3, item 1
29 CFR 1910.1200(f)(5)(i) · Hazard communication
Other-than-serious$0$0Oct 16, 1991Closed

Inspection 108577057 OPENED MAR 26, 1990Closed

Accident · Partial · Safety · 494 employees at the site · Closed Jun 12, 1990

1700 East 4th Street, Seymour, IN 47274 · OSHA's record · Phone and website on Google Maps

Incident on Feb 28, 1990: New, untrained employee's fingers amputated in power press

At approximately 6:05 p.m. on February 28, 1990, Employee #1, a 29-year-old newl y-hired (2 days) employee of Aisin USA Manufacturing, Inc., had been rudimentari ly trained by another inexperienced press operator for four to five part cycles. The training had begun about 45 minutes before Employee #1, having run only 10 parts by himself, reached through a gaping opening (8 in. high by 13 1/2 in. wid e) in a lexan plexiglass barrier guard to guide parts. With his left hand still in the die impact zone of the point of operation, Employee #1 leaned forward, pl aced his weight on the foot pedal, and accidentally tripped the Aida 30 ton part revolution mechanical power press, model #NCI-45 (2). His entire left index fin ger and the first two phalanges of the middle left finger were crushed and amput ated. The barrier guard was completely insufficient and the training practices w ere poor; neither management nor maintenance had inspected the press for at leas t 7 months prior to the accident.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$400$400May 14, 1990Closed
Citation 1, item 2a
29 CFR 1910.217(c)(2)(ia) · Mechanical power presses
Serious$1,000$1,000May 4, 1990Closed
Citation 1, item 2b
29 CFR 1910.217(e)(1)(i) · Mechanical power presses
Serious$0$0May 14, 1990Closed
Citation 1, item 2c
29 CFR 1910.217(f)(2) · Mechanical power presses
Serious$0$0May 14, 1990Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.106(g)(9)

(9) Fire control. Each service station shall be provided with at least one fire extinguisher having a minimum approved classification of 6 B, C, located so that an extinguisher, will be within 75 feet of each pump, dispenser, underground fill pipe opening, and lubrication or service room.

29 CFR 1910.108 · [Reserved]

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.184 · Slings

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.254 · Arc welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.36 · Exit route design

29 CFR 2200.801

Other other motor vehicle parts manufacturing employers in Indiana

Alert subscribers get notified of each newly cited employer in Indiana the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.