Albany ST. Auto LLC: OSHA inspections and violations

Springfield, Massachusetts · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

1inspections
17citation items
$2,800current penalties
Apr 27, 2015last inspection

OSHA has inspected Albany ST. Auto LLC once in Massachusetts.

The inspection began on Apr 27, 2015 after a complaint, in Springfield.

That inspection ended with 17 citation items: 17 serious.

Penalties were first proposed at $5,600 and now stand at $2,800, 50% lower after settlements or reviews.

Spray painting and finishing comes up most often in these citations: 8 items under 1910.107.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Albany ST. Auto LLC averages $2,800 (1 cited inspection).

Albany ST. Auto LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Massachusetts · latest 90 days of OSHA records

256employers cited

Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Massachusetts

Checking a subcontractor, a client or your own company? Watch Albany ST. Auto LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340588466 OPENED APR 27, 2015Closed

Complaint · Partial · Health · 8 employees at the site · Closed Oct 1, 2015

425 St James Ave, Springfield, MA 01109 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.106(d)(3)(ii)(a) · Flammable liquids
Serious$0$0Aug 14, 2015Final
Citation 1, item 1b
29 CFR 1910.107(c)(2) · Spray painting and finishing
Serious$0$0Aug 14, 2015Final
Citation 1, item 1c
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Aug 14, 2015Final
Citation 1, item 1d
29 CFR 1910.107(d)(4) · Spray painting and finishing
Serious$0$0Aug 14, 2015Final
Citation 1, item 1e
29 CFR 1910.107(d)(5) · Spray painting and finishing
Serious$0$0Aug 14, 2015Final
Citation 1, item 1f
29 CFR 1910.107(e)(2) · Spray painting and finishing
Serious$0$0Aug 14, 2015Final
Citation 1, item 1g
29 CFR 1910.107(g)(5) · Spray painting and finishing
Serious$0$0Aug 14, 2015Final
Citation 1, item 1h
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Aug 14, 2015Final
Citation 1, item 1i
29 CFR 1910.107(h)(12) · Spray painting and finishing
Serious$0$0Aug 14, 2015Final
Citation 1, item 2
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$2,800$1,400Aug 14, 2015Final
Citation 1, item 3
29 CFR 1910.141(g)(2) · Sanitation
Serious$0$0Aug 14, 2015Final
Citation 1, item 4
29 CFR 1910.151(c) · First aid and eyewash
Serious$0$0Aug 14, 2015Final
Citation 1, item 5a
29 CFR 1910.212(b) · Machine guarding
Serious$0$0Aug 14, 2015Final
Citation 1, item 5b
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$0$0Aug 14, 2015Final
Citation 1, item 5c
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$0$0Aug 14, 2015Final
Citation 1, item 6
29 CFR 1910.305(a)(2)(ii) · Electrical wiring methods
Serious$0$0Aug 14, 2015Final
Citation 1, item 7
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$2,800$1,400Aug 14, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(ii)(a)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(2)

(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.141 · Sanitation

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.305 · Electrical wiring methods

Other automotive body, paint, and interior repair and maintenance employers in Massachusetts

Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.