OSHA SearchOSHA records by employer

All Dimension Construction: OSHA inspections and violations

New York, New York · Industrial Building Construction · NAICS 236210

1inspections
6citation items
$11,568current penalties
Aug 13, 2020last inspection

All Dimension Construction has one OSHA inspection on record in New York.

OSHA opened it on Aug 13, 2020 after a complaint, in New York.

From that inspection OSHA issued 6 citation items: 6 serious.

OSHA proposed $11,568 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,079. All Dimension Construction averages $11,568 over 1 cited inspection in that time.

All Dimension Construction: OSHA citation items per year, 2020 to 2020
Citation items per year, by inspection date.

Want to know if OSHA cites All Dimension Construction again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 344885611 OPENED AUG 13, 2020Closed

Complaint · Complete · Safety · 22 employees at the site · Closed Oct 7, 2024

165 William St, New York, NY 10038 · Industrial Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.405(j)(1)(i) · Job-site wiring
Serious$3,856$3,856Dec 9, 2020Final
Citation 1, item 1b
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Serious$0$0Dec 9, 2020Final
Citation 1, item 2a
29 CFR 1926.451(b)(4) · Scaffolds, general requirements
Serious$3,856$3,856Dec 9, 2020Final
Citation 1, item 2b
29 CFR 1926.451(b)(10) · Scaffolds, general requirements
Serious$0$0Dec 9, 2020Final
Citation 1, item 2c
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0Dec 9, 2020Final
Citation 1, item 3
OSH Act Section 5(a)(1) · General Duty Clause
Serious$3,856$3,856Dec 9, 2020Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.405(g)(2)(iv)

(iv) Strain relief. Flexible cords shall be connected to devices and fittings so that strain relief is provided which will prevent pull from being directly transmitted to joints or terminal screws.

29 CFR 1926.405(j)(1)(i)

(j) Equipment for general use—(1) Lighting fixtures, lampholders, lamps, and receptacles—(i) Live parts. Fixtures, lampholders, lamps, rosettes, and receptacles shall have no live parts normally exposed to employee contact. However, rosettes and cleat-type lampholders and receptacles located at least 8 feet (2.44 m) above the floor may have exposed parts.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(10)

(10) Scaffold components manufactured by different manufacturers shall not be intermixed unless the components fit together without force and the scaffold's structural integrity is maintained by the user. Scaffold components manufactured by different manufacturers shall not be modified in order to intermix them unless a competent person determines the resulting scaffold is structurally sound.