OSHA SearchOSHA records by employer

All Jersey Construction LLC: OSHA inspections and violations

Piscataway, New Jersey · Masonry Contractors · NAICS 238140

3inspections
10citation items
$35,834current penalties
Oct 23, 2020last inspection

All Jersey Construction LLC has 3 OSHA inspections on record in New Jersey, the first in 2011.

OSHA's last visit started on Oct 23, 2020 after a complaint, in Union.

Across those inspections OSHA issued 10 citation items: 9 serious and 1 repeat.

OSHA proposed $35,834 in penalties and the amount has not been reduced.

Most often, OSHA cited 1926.451, scaffolds, general requirements (8 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. All Jersey Construction LLC averages $12,874 over 1 cited inspection in that time.

All Jersey Construction LLC: OSHA citation items per year, 2011 to 2020
Citation items per year, by inspection date.

New Jersey · latest 90 days of OSHA records

264employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in New Jersey: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Jersey

Checking a subcontractor, a client or your own company? Watch All Jersey Construction LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344992623 OPENED OCT 23, 2020Closed

Complaint · Partial · Safety · 8 employees at the site · Closed Feb 21, 2024

957 Stuyvesant Ave, Union, NJ 07083 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Serious$2,341$2,341Apr 2, 2021Final
Citation 1, item 2
29 CFR 1926.451(b)(1)(i) · Scaffolds, general requirements
Serious$4,096$4,096Apr 2, 2021Final
Citation 1, item 3
29 CFR 1926.451(f)(14) · Scaffolds, general requirements
Serious$2,341$2,341Apr 2, 2021Final
Citation 1, item 4a
29 CFR 1926.451(g)(1)(vi) · Scaffolds, general requirements
Serious$4,096$4,096Apr 2, 2021Final
Citation 1, item 4b
29 CFR 1926.454(a) · Scaffold training
Serious$0$0Apr 2, 2021Final

Inspection 339368268 OPENED AUG 30, 2013Closed

Unprogrammed other · Complete · Safety · 5 employees at the site · Closed Mar 8, 2019

811 - 846 Liberty Court, Piscataway, NJ 08854 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$6,160$6,160Sep 25, 2013Final

Inspection 315640995 OPENED OCT 14, 2011Closed

Planned · Partial · Safety · 5 employees at the site · Closed Dec 18, 2014

1650 Stelton Road, Piscataway, NJ 08854 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(1) · Scaffolds, general requirements
Serious$4,200$4,200Jan 20, 2012Closed
Citation 1, item 2
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$4,200$4,200Jan 20, 2012Closed
Citation 1, item 3
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,200$4,200Jan 20, 2012Closed
Citation 1, item 4
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$4,200$4,200Jan 20, 2012Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(b)(1)(i)

(i) Each platform unit (e.g., scaffold plank, fabricated plank, fabricated deck, or fabricated platform) shall be installed so that the space between adjacent units and the space between the platform and the uprights is no more than 1 inch (2.5 cm) wide, except where the employer can demonstrate that a wider space is necessary (for example, to fit around uprights when side brackets are used to extend the width of the platform).

29 CFR 1926.451(c)(1)

(c) Criteria for supported scaffolds. (1) Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) shall be restrained from tipping by guying, tying, bracing, or equivalent means, as follows:

29 CFR 1926.454 · Scaffold training

Other masonry contractors employers in New Jersey

Alert subscribers get notified of each newly cited employer in New Jersey the morning it is posted. See the alert plans.