OSHA SearchOSHA records by employer

All Trades Electrical Contractors, Inc.: OSHA inspections and violations

El Paso, Texas · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

8inspections
9citation items
$8,345current penalties
Feb 6, 2025last inspection

OSHA has inspected All Trades Electrical Contractors, Inc. 8 times in Texas since 2003.

The latest one began on Feb 6, 2025 as a planned inspection, in El Paso.

Those inspections ended with 9 citation items: 6 serious and 3 other-than-serious.

Penalties were first proposed at $15,569 and now stand at $8,345, 46% lower after settlements or reviews.

Electrical safety in construction comes up most often in these citations: 3 items under 1926.416.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and All Trades Electrical Contractors, Inc. averages $2,365 (2 cited inspections).

All Trades Electrical Contractors, Inc. also files yearly injury logs with OSHA, summarized below.

All Trades Electrical Contractors, Inc.: OSHA citation items per year, 2003 to 2025
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

399employers cited

9 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch All Trades Electrical Contractors, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348027061 OPENED FEB 6, 2025Closed

Planned · Partial · Safety · 29 employees at the site · Closed May 2, 2025

12302 Montana Ave. Bld. D, El Paso, TX 79938 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1053(b)(4) · Ladders in construction
Other-than-serious$930$930Feb 12, 2025Final

Inspection 342178480 OPENED MAR 17, 2017Closed

Referral · Partial · Safety · 34 employees at the site · Closed Jul 31, 2017

5625 South Desert Blvd., El Paso, TX 79932 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Mar 15, 2017: Employee is injured in fall from ladder after receiving elec

At approximately 2:30 p.m. on March 15, 2017, an employee was replacing light fixtures. He made contact with live wire. The electricity shocked the employee and he fell off of the ladder, injuring his shoulder. The employee was hospitalized and treated for his injuries.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$6,464$3,800May 11, 2017Final
Citation 1, item 1b
29 CFR 1926.416(a)(3) · Electrical safety in construction
Serious$0$0May 11, 2017Final

Inspection 313499931 OPENED MAR 2, 2011Closed

Planned · Partial · Safety · 47 employees at the site · Closed May 8, 2012

1031 Hawkins, El Paso, TX 79925 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.67(c)(2)(v) · Vehicle-mounted elevating and rotating work platforms
Serious$3,500$2,310Jun 28, 2011Closed

Inspection 313497216 OPENED MAR 11, 2010Closed

Unprogrammed other · Partial · Safety · 3 employees at the site · Closed Nov 17, 2010

3420 Joe Battle, El Paso, TX 79936 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$900$540Aug 20, 2010Closed
Citation 1, item 2
29 CFR 1926.416(e)(1) · Electrical safety in construction
Serious$900$540Aug 20, 2010Closed

Inspection 307265074 OPENED JUN 17, 2009Closed

Unprogrammed other · Complete · Health · 3 employees at the site · Closed Jan 28, 2010

Building 746, Fort Bliss, TX 79916 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.62(d)(1)(i) · Lead in construction
Other-than-serious$2,500$0Nov 9, 2009Closed

Inspection 307242347 OPENED JUL 14, 2004Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Sep 13, 2004

Sun Bowl Dr. (kelly Hall-utep), El Paso, TX 79902 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Serious$375$225Jul 21, 2004Closed

Inspection 301575569 OPENED SEP 17, 2003Closed

Planned · Partial · Health · 2 employees at the site · Closed Apr 27, 2004

7575 N. Mesa, El Paso, TX 79928 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Jan 30, 2004Closed

Inspection 301575742 OPENED SEP 17, 2003Closed

Planned · Partial · Safety · 3 employees at the site · Closed Sep 17, 2003

7575 N. Mesa, El Paso, TX 79928 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the El Paso site logged 2 recordable injuries or illnesses among about 25 workers: 8.1 per 100 full-time workers, against a median of 1.8 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
All Trades Electrical Contractors Inc.
El Paso · 2025
25 208.11.8
All Trades Electrical Contractors, Inc.
El Paso · 2018
30 3213.51.8

Included with any plan: 6 more yearly logs from these sites, back to 2016, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.67 · Vehicle-mounted elevating and rotating work platforms

29 CFR 1910.67(c)(2)(v)

(v) A personal fall arrest or travel restraint system that meets the requirements in subpart I of this part shall be worn and attached to the boom or basket when working from an aerial lift.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(4)

(4) Ladders shall be used only for the purpose for which they were designed.

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.403(i)(2)(i)

(2) Guarding of live parts. (i) Except as required or permitted elsewhere in this subpart, live parts of electric equipment operating at 50 volts or more shall be guarded against accidental contact by cabinets or other forms of enclosures, or by any of the following means:

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.51 · Sanitation

29 CFR 1926.62 · Lead in construction

Other electrical contractors and other wiring installation contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.