OSHA SearchOSHA records by employer

Allan Canady Builder, Inc.: OSHA inspections and violations

Willow Spring, North Carolina · New Single-Family Housing Construction (except For-Sale Builders) · NAICS 236115

1inspections
8citation items
$2,000current penalties
Jul 16, 2018last inspection

OSHA has inspected Allan Canady Builder, Inc. once in North Carolina.

The inspection began on Jul 16, 2018, in Willow Spring.

That inspection ended with 8 citation items: 3 serious and 5 other-than-serious.

Penalties were first proposed at $2,000 and still stand at $2,000.

Ground-fault protection on job sites comes up most often in these citations: 2 items under 1926.404.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Allan Canady Builder, Inc. averages $2,000 (1 cited inspection).

Allan Canady Builder, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

236employers cited

3 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Allan Canady Builder, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343301362 OPENED JUL 16, 2018Closed

Unprogrammed other · Complete · Safety · 1 employee at the site · Closed Dec 11, 2019

30 Gloria Grande Ct., Willow Spring, NC 27592 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,000$1,000Nov 5, 2018Final
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0Nov 5, 2018Final
Citation 1, item 2
29 CFR 1926.1053(b)(1) · Ladders in construction
Serious$1,000$1,000Nov 5, 2018Final
Citation 2, item 1
29 CFR 1926.150(c)(1)(i) · Fire protection
Other-than-serious$0$0Nov 5, 2018Final
Citation 2, item 2a
29 CFR 1926.404(b)(1)(iii)(c) · Ground-fault protection on job sites
Other-than-serious$0$0Nov 5, 2018Final
Citation 2, item 2b
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Nov 5, 2018Final
Citation 2, item 2c
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Nov 5, 2018Final
Citation 2, item 2d
29 CFR 1926.416(e)(1) · Electrical safety in construction
Other-than-serious$0$0Nov 5, 2018Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.1053(b)(1)

(1) When portable ladders are used for access to an upper landing surface, the ladder side rails shall extend at least 3 feet (.9 m) above the upper landing surface to which the ladder is used to gain access; or, when such an extension is not possible because of the ladder's length, then the ladder shall be secured at its top to a rigid support that will not deflect, and a grasping device, such as a grabrail, shall be provided to assist employees in mounting and dismounting the ladder. In no case shall the extension be such that ladder deflection under a load would, by itself, cause the ladder to slip off its support.

29 CFR 1926.150 · Fire protection

29 CFR 1926.150(c)(1)(i)

(c) Portable firefighting equipment—(1) Fire extinguishers and small hose lines. (i) A fire extinguisher, rated not less than 2A, shall be provided for each 3,000 square feet of the protected building area, or major fraction thereof. Travel distance from any point of the protected area to the nearest fire extinguisher shall not exceed 100 feet.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.501 · Fall protection in construction

Other new single-family housing construction (except for-sale builders) employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.