Inspection 342250388 OPENED APR 13, 2017Closed
200 Quinn Drive, Pittsburgh, PA 15275 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Imperial, Pennsylvania · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813
OSHA has inspected Allegheny Metal Finishing 3 times in Pennsylvania since 2009.
The latest one began on Apr 13, 2017 on a referral, in Pittsburgh.
Those inspections ended with 6 citation items: 5 serious and 1 other-than-serious.
Penalties were first proposed at $3,600 and now stand at $2,700, 25% lower after settlements or reviews.
Spray painting and finishing comes up most often in these citations: 4 items under 1910.107.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Allegheny Metal Finishing averages $2,700 (1 cited inspection).
Pennsylvania · latest 90 days of OSHA records
277employers cited
Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Pennsylvania
Checking a subcontractor, a client or your own company? Watch Allegheny Metal Finishing and get notified the morning OSHA posts a new citation for it.
Watch this company200 Quinn Drive, Pittsburgh, PA 15275 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
8150 Steubenville Pike, Imperial, PA 15126 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Serious | $1,200 | $900 | Feb 5, 2016 | Final |
| Citation 1, item 1b 29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing |
Serious | $0 | $0 | Feb 5, 2016 | Final |
| Citation 1, item 2 29 CFR 1910.107(b)(9) · Spray painting and finishing |
Serious | $1,200 | $900 | Feb 5, 2016 | Final |
| Citation 1, item 3a 29 CFR 1910.1200(e)(1) · Hazard communication |
Serious | $1,200 | $900 | Feb 5, 2016 | Final |
| Citation 1, item 3b 29 CFR 1910.1200(h)(3)(iv) · Hazard communication |
Serious | $0 | $0 | Feb 5, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.107(l)(4)(iii) · Spray painting and finishing |
Other-than-serious | $0 | $0 | Feb 5, 2016 | Final |
8150 Steubenville Pike, Imperial, PA 15126 · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(5)(iv)
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
29 CFR 1910.107(b)(9)
(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.
Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.