OSHA SearchOSHA records by employer

Allegheny Metal Finishing: OSHA inspections and violations

Imperial, Pennsylvania · Electroplating, Plating, Polishing, Anodizing, and Coloring · NAICS 332813

3inspections
6citation items
$2,700current penalties
Apr 13, 2017last inspection

OSHA has inspected Allegheny Metal Finishing 3 times in Pennsylvania since 2009.

The latest one began on Apr 13, 2017 on a referral, in Pittsburgh.

Those inspections ended with 6 citation items: 5 serious and 1 other-than-serious.

Penalties were first proposed at $3,600 and now stand at $2,700, 25% lower after settlements or reviews.

Spray painting and finishing comes up most often in these citations: 4 items under 1910.107.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Allegheny Metal Finishing averages $2,700 (1 cited inspection).

Allegheny Metal Finishing: OSHA citation items per year, 2009 to 2017
Citation items per year, by inspection date.

Pennsylvania · latest 90 days of OSHA records

277employers cited

Get notified the morning OSHA posts each new citation in Pennsylvania: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Pennsylvania

Checking a subcontractor, a client or your own company? Watch Allegheny Metal Finishing and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342250388 OPENED APR 13, 2017Closed

Referral · Partial · Safety · 15 employees at the site · Closed Apr 21, 2017

200 Quinn Drive, Pittsburgh, PA 15275 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341073724 OPENED NOV 20, 2015Closed

Planned · Complete · Health · 8 employees at the site · Closed May 17, 2016

8150 Steubenville Pike, Imperial, PA 15126 · Electroplating, Plating, Polishing, Anodizing, and Coloring · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$1,200$900Feb 5, 2016Final
Citation 1, item 1b
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$0$0Feb 5, 2016Final
Citation 1, item 2
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$1,200$900Feb 5, 2016Final
Citation 1, item 3a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,200$900Feb 5, 2016Final
Citation 1, item 3b
29 CFR 1910.1200(h)(3)(iv) · Hazard communication
Serious$0$0Feb 5, 2016Final
Citation 2, item 1
29 CFR 1910.107(l)(4)(iii) · Spray painting and finishing
Other-than-serious$0$0Feb 5, 2016Final

Inspection 312632664 OPENED APR 17, 2009Closed

Planned · No inspection · Health · 6 employees at the site · Closed Apr 17, 2009

8150 Steubenville Pike, Imperial, PA 15126 · Metal Coating, Engraving (except Jewelry and Silverware), and Allied Services to Manufacturers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.1200 · Hazard communication

Other electroplating, plating, polishing, anodizing, and coloring employers in Pennsylvania

Alert subscribers get notified of each newly cited employer in Pennsylvania the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.