Inspection 345260962 OPENED APR 19, 2021Closed
4 Barnes Street, Ware, MA 01082 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Westborough, Massachusetts · Residential Remodelers · NAICS 236118
Since 2019, OSHA inspectors have visited Alliance Home Improvement, Inc. in Massachusetts 2 times.
The most recent inspection opened on Apr 19, 2021 after a complaint, in Ware.
In all, OSHA issued 3 citation items: 3 serious.
The proposed penalties came to $5,683; today they stand at $2,850, 50% less.
The rule cited most here is 1926.304 (woodworking tools), 2 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Alliance Home Improvement, Inc. averages $2,850 across 1 cited inspection.
Massachusetts · latest 90 days of OSHA records
256employers cited
5 of them in the same industry
Get notified the morning OSHA posts each new citation in Massachusetts: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Massachusetts
Checking a subcontractor, a client or your own company? Watch Alliance Home Improvement, Inc. and get notified the morning OSHA posts a new citation for it.
Watch this company4 Barnes Street, Ware, MA 01082 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
5 Olde Connecticut Path, Westborough, MA 01581 · Residential Remodelers · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.20(b)(2) · Construction safety programs |
Serious | $1,705 | $872 | Jun 13, 2019 | Final |
| Citation 1, item 2a 29 CFR 1926.304(f) · Woodworking tools |
Serious | $3,978 | $1,978 | Jun 13, 2019 | Final |
| Citation 1, item 2b 29 CFR 1926.304(i)(1) · Woodworking tools |
Serious | $0 | $0 | Jun 13, 2019 | Final |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1926.20(b)(2)
(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.
29 CFR 1926.304(f)
(f) Other requirements. All woodworking tools and machinery shall meet other applicable requirements of American National Standards Institute, 01.1-1961, Safety Code for Woodworking Machinery.
29 CFR 1926.304(i)(1)
(i) Hand-fed ripsaws. (1) Each circular hand-fed ripsaw shall be guarded by a hood which shall completely enclose that portion of the saw above the table and that portion of the saw above the material being cut. The hood and mounting shall be arranged so that the hood will automatically adjust itself to the thickness of and remain in contact with the material being cut but it shall not offer any considerable resistance to insertion of material to saw or to passage of the material being sawed. The hood shall be made of adequate strength to resist blows and strains incidental to reasonable operation, adjusting, and handling, and shall be so designed as to protect the operator from flying splinters and broken saw teeth. It shall be made of material that is soft enough so that it will be unlikely to cause tooth breakage. The hood shall be so mounted as to insure that its operation will be po
Alert subscribers get notified of each newly cited employer in Massachusetts the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.