OSHA SearchOSHA records by employer

Allied Electric Sign & Awning Co.: OSHA inspections and violations

West Valley City, Utah · Sign Manufacturing · NAICS 339950

2inspections
7citation items
$2,550current penalties
Jul 21, 2021last inspection

OSHA has inspected Allied Electric Sign & Awning Co. 2 times in Utah since 2020.

The latest one began on Jul 21, 2021 after a complaint, in Springville.

Those inspections ended with 7 citation items: 7 serious.

Penalties were first proposed at $2,550 and still stand at $2,550.

Spray painting and finishing comes up most often in these citations: 5 items under 1910.107.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Allied Electric Sign & Awning Co. averages $2,550 (1 cited inspection).

Allied Electric Sign & Awning Co.: OSHA citation items per year, 2020 to 2021
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

70employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Allied Electric Sign & Awning Co. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345432777 OPENED JUL 21, 2021Closed

Complaint · Partial · Health · 15 employees at the site · Closed Mar 22, 2022

1852 N Parkway Ct, Springville, UT 84663 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(c)(5) · Spray painting and finishing
Serious$1,500$1,500Oct 20, 2021Final
Citation 1, item 1b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Oct 20, 2021Final
Citation 1, item 1c
29 CFR 1910.107(d)(11) · Spray painting and finishing
Serious$0$0Oct 20, 2021Final
Citation 1, item 1d
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Oct 20, 2021Final
Citation 1, item 1e
29 CFR 1910.107(j)(2) · Spray painting and finishing
Serious$0$0Oct 20, 2021Final
Citation 1, item 2a
29 CFR 1910.134(c)(2)(ii) · Respiratory protection
Serious$1,050$1,050Oct 20, 2021Final
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Oct 20, 2021Final

Inspection 344568381 OPENED JAN 21, 2020Closed

Referral · Partial · Safety · 100 employees at the site · Closed May 15, 2020

2678 S. 5600 W., West Valley City, UT 84120 · Sign Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(5)

(5) Combustible residues, areas. Unless specifically approved for locations containing both deposits of readily ignitable residue and explosive vapors, there shall be no electrical equipment in any spraying area, whereon deposits of combustible residues may readily accumulate, except wiring in rigid conduit or in boxes or fittings containing no taps, splices, or terminal connections.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(d)(11)

(11) Room intakes. Air intake openings to rooms containing spray finishing operations shall be adequate for the efficient operation of exhaust fans and shall be so located as to minimize the creation of dead air pockets.

29 CFR 1910.134 · Respiratory protection

Other sign manufacturing employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.