Inspection 341370401 OPENED APR 1, 2016Closed
65 Goodway Drive South, Rochester, NY 14625 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Since 1985, OSHA inspectors have visited Alpha Iron Works in New York 8 times.
The most recent inspection opened on Apr 1, 2016 after a complaint, in Rochester.
In all, OSHA issued 13 citation items: 11 serious and 2 other-than-serious.
The proposed penalties came to $17,644; today they stand at $6,830, 61% less.
The rule cited most here is 1910.107 (spray painting and finishing), 4 times.
Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. Alpha Iron Works averages $2,500 across 1 cited inspection.
Alpha Iron Works also files yearly injury logs with OSHA, summarized below.
It reported 2 severe injuries to OSHA since 2015.
New York · latest 90 days of OSHA records
353employers cited
Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in New York
Checking a subcontractor, a client or your own company? Watch Alpha Iron Works and get notified the morning OSHA posts a new citation for it.
Watch this company65 Goodway Drive South, Rochester, NY 14625 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1440 Empire Boulevard, Penfield, NY 14526 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(a)(2) · Fall protection in construction |
Serious | $4,900 | $2,500 | Jun 15, 2016 | Final |
1 College Circle Letchworth Dining Hall, Geneseo, NY 14454 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.760(a)(1) · Fall protection |
Other-than-serious | $2,000 | $0 | Dec 6, 2013 | Final |
139 Fairbanks Road, Churchville-chili Csd, Churchville, NY 14228 · All Other Specialty Trade Contractors · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.760(a)(1) · Fall protection |
Serious | $2,800 | $1,650 | Aug 28, 2013 | Final |
435 State Street, Rochester, NY 14608 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.352(d) · Fire prevention |
Serious | $1,734 | $0 | Dec 8, 2011 | Closed |
| Citation 1, item 2 29 CFR 1926.404(b)(1)(ii) · Ground-fault protection on job sites |
Serious | $2,040 | $1,020 | Dec 8, 2011 | Closed |
1 Lomb Memorial Drive - Gleason Hall, Rochester, NY 14623 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.501(b)(1) · Fall protection in construction |
Serious | $1,050 | $600 | Jul 10, 1998 | Closed |
921 Maple Street, Rochester, NY 14611 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.107(b)(5)(i) · Spray painting and finishing |
Serious | $600 | $250 | Apr 15, 1993 | Final |
| Citation 1, item 1b 29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing |
Serious | $0 | $0 | Apr 15, 1993 | Final |
| Citation 1, item 2 29 CFR 1910.107(b)(10) · Spray painting and finishing |
Other-than-serious | $600 | $0 | Apr 15, 1993 | Final |
| Citation 1, item 3 29 CFR 1910.107(e)(4) · Spray painting and finishing |
Serious | $600 | $250 | Apr 15, 1993 | Final |
| Citation 1, item 4 29 CFR 1910.147(c)(1) · Lockout/tagout |
Serious | $600 | $250 | Apr 15, 1993 | Final |
| Citation 1, item 5 29 CFR 1910.252(b)(2)(iii) · Welding fire safety |
Serious | $600 | $250 | Apr 15, 1993 | Final |
255 East Avenue, Rochester, NY 14604 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1926.500(d)(1) · Scope, application, and definitions applicable to this subpart |
Serious | $120 | $60 | Jul 2, 1985 | Closed |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2024, the Rochester site logged 0 recordable injuries or illnesses among about 14 workers: 0.0 per 100 full-time workers, against a median of 3.6 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Alpha Iron Works LLC Rochester · 2024 | 14 | 0 | 0 | 0.0 | 3.6 |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 2 reports on file.
Mar 19, 2019, Rochester: Hospitalization, amputation · amputations · toes(s), toenail(s)
A temporary employee was welding an end plate on a beam. The clamp was on the beam and he was moving the beam to a vertical position when the beam fell on his right foot, causing the amputation of two toes. Steel toe safety shoes were worn at the time.
Mar 3, 2016, Penfield: Hospitalization · fractures · nonclassifiable
An employee fell 12.5 feet from a stair landing to the ground and was hospitalized with multiple fractures.
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.107(b)(10)
(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.
29 CFR 1910.107(b)(5)(i)
(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.
29 CFR 1910.107(b)(5)(iv)
(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.
Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.