OSHA SearchOSHA records by employer

Alpine Steel, LLC: OSHA inspections and violations

Colorado Springs, Colorado · Structural Steel and Precast Concrete Contractors · NAICS 238120

6inspections
14citation items
$4,938current penalties
Feb 19, 2025last inspection

Alpine Steel, LLC has 6 OSHA inspections on record in Colorado, the first in 1985.

OSHA's last visit started on Feb 19, 2025 on a referral, in Glenwood Springs.

Across those inspections OSHA issued 14 citation items: 9 serious and 5 other-than-serious.

OSHA proposed $11,932 in penalties. After settlements and reviews the total is $4,938, down 59%.

Most often, OSHA cited 1910.212, machine guarding (3 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Alpine Steel, LLC averages $3,518 over 1 cited inspection in that time.

1 inspection on this page followed a fatal incident.

It reported 1 severe injury to OSHA since 2015.

Alpine Steel, LLC: OSHA citation items per year, 1985 to 2025
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

130employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch Alpine Steel, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348053059 OPENED FEB 19, 2025Closed

Referral · Partial · Safety · 2 employees at the site · Closed Feb 20, 2026

755 Airport Road, Glenwood Springs, CO 81601 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$4,965$2,482Jul 1, 2025Final
Citation 2, item 1
29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries
Other-than-serious$3,547$1,035Jul 1, 2025Final

Inspection 310594353 OPENED DEC 17, 2007Closed

Unprogrammed related · Partial · Safety · 15 employees at the site · Closed Feb 11, 2008

4105 & 4125 Briargate Pkwy, 105orado Springs, CO 80920 · Structural Steel and Precast Concrete Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.502(b)(3) · Fall protection systems
Serious$1,500$500Jan 18, 2008Closed
Citation 1, item 1b
29 CFR 1926.502(b)(9) · Fall protection systems
Serious$0$0Jan 18, 2008Closed
Citation 1, item 2a
29 CFR 1926.1052(c)(1)(ii) · Stairways in construction
Serious$1,500$500Jan 18, 2008Closed
Citation 1, item 2b
29 CFR 1926.1052(c)(12) · Stairways in construction
Serious$0$0Jan 18, 2008Closed

Inspection 100677111 OPENED DEC 12, 1986Closed

Planned · Complete · Safety · 3 employees at the site · Closed Dec 16, 1986

5225 Alturas Dr., Colorado Springs, CO 80911 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 100016658 OPENED JAN 30, 1986Closed

Planned · Complete · Safety · 5 employees at the site · Closed Feb 18, 1986

5550 N. Union Blvd., Colorado Springs, CO 80901 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 648360 OPENED JUN 26, 1985Closed

Accident · Complete · Safety · 13 employees at the site · Closed Jul 29, 1985

2380 N. Marksheffel Rd ., Colorado Springs, CO 80915 · OSHA's record · Phone and website on Google Maps

Incident on Jun 25, 1985 (fatal): Electric shock - direct contact with energized parts

AN EMPLOYEE WAS TIGHTENING BOLTS ON A STEEL COLUMN LOCATED NEXT TO THE RUNWAY CO NDUCTORS FOR AN OVERHEAD CRANE. THE EMPLOYEE LAID ON THE COLUMN TO REACH A BOLT AND CONTACTED THE 240-VOLT RUNWAY CONDUCTORS. HE WAS ELECTROCUTED.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$180$180Jul 16, 1985Closed
Citation 1, item 1b
29 CFR 1910.179(g)(5)(i) · Overhead and gantry cranes
Serious$0$0Jul 16, 1985Closed
Citation 1, item 1c
29 CFR 1910.179(l)(2)(i) · Overhead and gantry cranes
Serious$0$0Jul 16, 1985Closed
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$240$240Jul 16, 1985Closed
Citation 2, item 1
29 CFR 1904.2(a) · Partial exemption for establishments in certain industries
Other-than-serious$0$0Jul 16, 1985Closed
Citation 2, item 2
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Jul 16, 1985Closed
Citation 2, item 3
29 CFR 1910.179(j)(3) · Overhead and gantry cranes
Other-than-serious$0$0Jul 16, 1985Closed
Citation 2, item 4
29 CFR 1910.212(a)(1) · Machine guarding
Other-than-serious$0$0Jul 16, 1985Closed

Inspection 677369 OPENED JUN 7, 1985Closed

Planned · Complete · Safety · 10 employees at the site · Closed Jun 7, 1985

1125 Kelly Johnson Blvd., Colorado Springs, CO 80918 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Dec 27, 2024, Glenwood Springs: Hospitalization · open wounds involving internal organs, major blood vessels · internal neck structures

An employee was utilizing a hydraulic ironworker machine to punch plates for a structural steel job. A piece of metal came off and punctured his trachea.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.2 · Partial exemption for establishments in certain industries

29 CFR 1904.39 · Reporting deaths and severe injuries

29 CFR 1904.39(a)(2)

(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(a)

(a) Application. Protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, shall be provided, used, and maintained in a sanitary and reliable condition wherever it is necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation or physical contact.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.179(g)(5)(i)

(5) Switches. (i) The power supply to the runway conductors shall be controlled by a switch or circuit breaker located on a fixed structure, accessible from the floor, and arranged to be locked in the open position.

29 CFR 1910.212 · Machine guarding

29 CFR 1926.1052 · Stairways in construction

29 CFR 1926.502 · Fall protection systems

Other structural steel and precast concrete contractors employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.