OSHA SearchOSHA records by employer

Alstate Steel: OSHA inspections and violations

Albuquerque, New Mexico · Fabricated Structural Metal Manufacturing · NAICS 332312

5inspections
18citation items
$15,925current penalties
Jun 24, 2022last inspection

OSHA has inspected Alstate Steel 5 times in New Mexico since 2001.

The latest one began on Jun 24, 2022 as a planned inspection, in Albuquerque.

Those inspections ended with 18 citation items: 12 serious and 6 other-than-serious.

Penalties were first proposed at $20,600 and now stand at $15,925, 23% lower after settlements or reviews.

Noise comes up most often in these citations: 2 items under 1910.95.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Alstate Steel averages $11,700 (1 cited inspection).

Alstate Steel: OSHA citation items per year, 2001 to 2022
Citation items per year, by inspection date.

New Mexico · latest 90 days of OSHA records

31employers cited

Get notified the morning OSHA posts each new citation in New Mexico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New Mexico

Checking a subcontractor, a client or your own company? Watch Alstate Steel and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346041007 OPENED JUN 24, 2022Closed

Planned · Complete · Safety · 35 employees at the site · Closed Jul 21, 2023

203 Murray Rd. Se, Albuquerque, NM 87105 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(a) · Compressed gases (general requirements)
Serious$2,700$2,700Dec 20, 2022Final
Citation 1, item 2
29 CFR 1910.147(a)(1)(i) · Lockout/tagout
Serious$2,700$2,700Dec 20, 2022Final
Citation 1, item 3
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$3,600$3,600Dec 20, 2022Final
Citation 1, item 4
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$2,700$2,700Dec 20, 2022Final
Citation 2, item 1
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Dec 20, 2022Final

Inspection 315256933 OPENED MAR 2, 2011Closed

Referral · Complete · Safety · 28 employees at the site · Closed Jul 20, 2011

208 Murry Rd Se, Albuquerque, NM 87105 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$875$0Mar 7, 2011Final

Inspection 311661821 OPENED JAN 23, 2008Closed

Planned · Complete · Safety · 29 employees at the site · Closed Jul 14, 2008

208 Murry Rd Se, Albuquerque, NM 87105 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(p)(1) · Forklifts and other powered industrial trucks
Other-than-serious$1,400$0Mar 10, 2008Final
Citation 1, item 2
29 CFR 1910.243(c)(3) · Guarding of portable powered tools
Serious$1,400$950Mar 10, 2008Final
Citation 1, item 3
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$800$550Mar 10, 2008Final
Citation 1, item 4
29 CFR 1910.253(e)(6)(ii) · Gas welding and cutting
Serious$800$550Mar 10, 2008Final
Citation 1, item 5
29 CFR 1910.255(d)(2) · Resistance welding
Serious$800$550Mar 10, 2008Final
Citation 1, item 6
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$600$0Mar 10, 2008Final
Citation 1, item 7
29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods
Serious$600$450Mar 10, 2008Final
Citation 1, item 8
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$1,400$950Mar 10, 2008Final
Citation 2, item 1
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Mar 10, 2008Final

Inspection 307123455 OPENED MAY 6, 2004Closed

Planned · Complete · Safety · 10 employees at the site · Closed May 17, 2004

208 Murry Rd Se, Albuquerque, NM 87105 · Ornamental and Architectural Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303403166 OPENED JAN 10, 2001Closed

Planned · Complete · Health · 18 employees at the site · Closed Jul 9, 2001

208 Murry Rd Se, Albuquerque, NM 87105 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$225$225May 7, 2001Closed
Citation 1, item 1b Serious$0$0May 7, 2001Closed
Citation 2, item 1
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0May 7, 2001Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(a)

(a) Inspection of compressed gas cylinders. Each employer shall determine that compressed gas cylinders under his control are in a safe condition to the extent that this can be determined by visual inspection. Visual and other inspections shall be conducted as prescribed in the Hazardous Materials Regulations of the Department of Transportation (49 CFR parts 171-179 and 14 CFR part 103). Where those regulations are not applicable, visual and other inspections shall be conducted in accordance with Compressed Gas Association Pamphlets C-6-1968 and C-8-1962, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(a)(1)(i)

(a) Scope, application, and purpose—(1) Scope. (i) This standard covers the servicing and maintenance of machines and equipment in which the unexpected energization or start up of the machines or equipment, or release of stored energy could cause injury to employees. This standard establishes minimum performance requirements for the control of such hazardous energy.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.243 · Guarding of portable powered tools

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.255 · Resistance welding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.95 · Noise

Other fabricated structural metal manufacturing employers in New Mexico

Alert subscribers get notified of each newly cited employer in New Mexico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.