OSHA SearchOSHA records by employer

AM Electric, LLC: OSHA inspections and violations

North Kingstown, Rhode Island · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
6citation items
$16,224current penalties
Feb 15, 2022last inspection

Since 2019, OSHA inspectors have visited AM Electric, LLC in Rhode Island 2 times.

The most recent inspection opened on Feb 15, 2022 on a referral, in Scituate.

In all, OSHA issued 6 citation items: 4 serious and 2 other-than-serious.

The proposed penalties came to $24,282; today they stand at $16,224, 33% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. AM Electric, LLC averages $8,112 across 2 cited inspections.

It reported 1 severe injury to OSHA since 2015.

AM Electric, LLC: OSHA citation items per year, 2019 to 2022
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

85employers cited

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch AM Electric, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345784359 OPENED FEB 15, 2022Closed

Referral · Partial · Safety · 20 employees at the site · Closed Sep 15, 2025

311 Danielson Pike, Scituate, RI 02857 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.21(b)(2) · Construction safety training
Serious$4,558$3,191May 10, 2022Final
Citation 1, item 2
29 CFR 1926.97(b)(2)(i) · Electrical protective equipment
Serious$4,558$3,191May 10, 2022Final
Citation 1, item 3
29 CFR 1926.416(a)(1) · Electrical safety in construction
Serious$4,558$3,191May 10, 2022Final

Inspection 344395769 OPENED OCT 23, 2019Closed

Referral · Partial · Safety · 12 employees at the site · Closed Dec 19, 2019

426 Smith Street, North Kingstown, RI 02852 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Incident on Oct 23, 2019: Employee sustains multiple fractures from jumping off crane

At 8:15 a.m. on October 23, 2019, an employee working as a crane operator for an electrical contractor had just hoisted five metal streetlight poles weighing approximately 4,662 pounds onto a tractor trailer. The employee lifted a load that exceeded the maximum lifting capacity of the derrick crane based on the boom configuration by more than 1,000 pounds. In addition, the employee did not assess ground conditions and use outrigger pads to ensure the load weight was properly supported. The employee was rotating the crane boom carrying the hoisted load when the crane tipped over. The employee jumped off the derrick from the high side of the equipment falling approximately eight feet to the ground. The employee fractured his wrist, three ribs, and his hip and was hospitalized to undergo surgery.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$5,304$4,000Nov 27, 2019Final
Citation 1, item 2
29 CFR 1910.135(a)(1) · Head protection
Other-than-serious$5,304$2,652Nov 27, 2019Final
Citation 2, item 1
29 CFR 1910.180(d)(6) · Crawler locomotive and truck cranes
Other-than-serious$0$0Nov 27, 2019Final

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.

Feb 14, 2022, Scituate: Hospitalization · electrical burns, unspecified · hand(s), unspecified

An employee was attempting to replace fluorescent lights with LED lights when he received an electrical shock, resulting in a burn to his hand.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.135 · Head protection

29 CFR 1910.135(a)(1)

(a) General requirements. (1) The employer shall ensure that each affected employee wears a protective helmet when working in areas where there is a potential for injury to the head from falling objects.

29 CFR 1910.180 · Crawler locomotive and truck cranes

29 CFR 1910.180(d)(6)

(6) Inspection records. Certification records which include the date of inspection, the signature of the person who performed the inspection and the serial number, or other identifier, of the crane which was inspected shall be made monthly on critical items in use such as brakes, crane hooks, and ropes. This certification record shall be kept readily available.

29 CFR 1926.21 · Construction safety training

29 CFR 1926.21(b)(2)

(2) The employer shall instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury.

29 CFR 1926.416 · Electrical safety in construction

29 CFR 1926.97 · Electrical protective equipment

OSH Act Section 5 · General Duty Clause

Other electrical contractors and other wiring installation contractors employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.