OSHA SearchOSHA records by employer

American East, Inc.: OSHA inspections and violations

Warwick, Rhode Island · Masonry Contractors · NAICS 238140

7inspections
16citation items
$7,988current penalties
Feb 27, 2017last inspection

OSHA has inspected American East, Inc. 7 times in Rhode Island since 1999.

The latest one began on Feb 27, 2017 after a complaint, in Cumberland.

Those inspections ended with 16 citation items: 8 serious, 1 repeat and 7 other-than-serious.

Penalties were first proposed at $14,928 and now stand at $7,988, 46% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 9 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and American East, Inc. averages $1,575 (2 cited inspections).

American East, Inc.: OSHA citation items per year, 1999 to 2017
Citation items per year, by inspection date.

Rhode Island · latest 90 days of OSHA records

76employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Rhode Island: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Rhode Island

Checking a subcontractor, a client or your own company? Watch American East, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342134293 OPENED FEB 27, 2017Closed

Complaint · Partial · Safety · 10 employees at the site · Closed May 1, 2017

132 Mendon Road, Cumberland, RI 02864 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.178(l)(1)(ii) · Forklifts and other powered industrial trucks
Serious$2,988$2,000Mar 6, 2017Final
Citation 2, item 1a
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$335$0Mar 6, 2017Final
Citation 2, item 1b
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Mar 6, 2017Final
Citation 2, item 1c
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Mar 6, 2017Final
Citation 2, item 1d
29 CFR 1910.134(k)(3) · Respiratory protection
Other-than-serious$0$0Mar 6, 2017Final

Inspection 341998540 OPENED DEC 28, 2016Closed

Planned · Partial · Safety · 8 employees at the site · Closed Feb 14, 2017

755 Centre Of New England Blvd., Coventry, RI 02816 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(4)(i) · Scaffolds, general requirements
Serious$1,630$1,150Jan 23, 2017Final

Inspection 339843583 OPENED JUL 10, 2014Closed

Complaint · Partial · Safety · 9 employees at the site · Closed Aug 13, 2014

1500 Bald Hill Rd., Warwick, RI 02886 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$2,800$1,400Jul 24, 2014Final
Citation 1, item 2
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Other-than-serious$2,800$0Jul 24, 2014Final

Inspection 310159496 OPENED FEB 12, 2008Closed

Unprogrammed other · Partial · Safety · 10 employees at the site · Closed May 5, 2008

860 West Main Rd., Middletown, RI 02840 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1)(vii) · Scaffolds, general requirements
Serious$1,500$1,500Feb 19, 2008Closed

Inspection 304994809 OPENED JAN 6, 2004Closed

Planned · Complete · Safety · 9 employees at the site · Closed Feb 10, 2004

Bald Hill Rd, Warwick, RI 02888 · Masonry Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Repeat$1,000$1,000Jan 27, 2004Closed
Citation 2, item 1
29 CFR 1926.1053(b)(5)(i) · Ladders in construction
Other-than-serious$0$0Jan 27, 2004Closed

Inspection 304989668 OPENED SEP 20, 2002Closed

Planned · Partial · Safety · 8 employees at the site · Closed Nov 12, 2002

1354 Bald Hill Rd, Warwick, RI 02888 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$750$375Oct 3, 2002Closed
Citation 1, item 2
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$750$375Oct 3, 2002Closed
Citation 2, item 1
29 CFR 1910.178(l) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Oct 3, 2002Closed

Inspection 300541984 OPENED APR 16, 1999Closed

Unprogrammed related · Complete · Safety · 5 employees at the site · Closed Jun 17, 1999

345 Harris Ave., Providence, RI 02903 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$375$188May 27, 1999Closed
Citation 1, item 1b
29 CFR 1926.451(f)(7) · Scaffolds, general requirements
Serious$0$0May 27, 1999Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(c)(1)

(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.

29 CFR 1910.134(e)(1)

(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.

29 CFR 1910.134(f)(1)

(1) Normal breathing. In a normal standing position, without talking, the subject shall breathe normally.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1926.1053 · Ladders in construction

29 CFR 1926.451 · Scaffolds, general requirements

Other masonry contractors employers in Rhode Island

Alert subscribers get notified of each newly cited employer in Rhode Island the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.