OSHA SearchOSHA records by employer

American Steel Fabricators Inc: OSHA inspections and violations

Farmington, Michigan · Plate Work Manufacturing · NAICS 332313

6inspections
66citation items
$9,450current penalties
Feb 2, 2022last inspection

OSHA has inspected American Steel Fabricators Inc 6 times in Michigan since 1995.

The latest one began on Feb 2, 2022 as a planned inspection, in Farmington.

Those inspections ended with 66 citation items: 23 serious, 6 repeat and 37 other-than-serious.

Penalties were first proposed at $13,200 and now stand at $9,450, 28% lower after settlements or reviews.

Flammable liquids comes up most often in these citations: 5 items under 1910.106.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and American Steel Fabricators Inc averages $3,350 (1 cited inspection).

American Steel Fabricators Inc: OSHA citation items per year, 1995 to 2022
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

617employers cited

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch American Steel Fabricators Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 345758353 OPENED FEB 2, 2022Closed

Planned · No inspection · Safety · Closed Feb 8, 2022

34150 W 9 Mile Rd, Farmington, MI 48335 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341527679 OPENED JUN 7, 2016Closed

Planned · Complete · Safety · State government · 8 employees at the site · Closed Jul 21, 2017

34150 W 9 Mile Rd, Farmington, MI 48335 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 408.10034(3)
Serious$400$200Jun 29, 2016Final
Citation 1, item 2
29 CFR 408.10123
Serious$400$200Jun 29, 2016Final
Citation 1, item 3
29 CFR 408.11875(2)
Serious$400$200Jun 29, 2016Final
Citation 2, item 1
29 CFR 408.12635(1)(A)
Repeat$2,000$1,000Jun 29, 2016Final
Citation 2, item 2
29 CFR 408.13370(1)
Repeat$1,600$800Jun 29, 2016Final
Citation 2, item 3
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Repeat$1,600$800Jun 29, 2016Final
Citation 3, item 1
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Other-than-serious$0$0Jun 29, 2016Final
Citation 4, item 1
29 CFR 408.11223(1)
Repeat$100$50Jun 29, 2016Final
Citation 4, item 2
29 CFR 408.11854(1)
Repeat$100$50Jun 29, 2016Final
Citation 4, item 3
29 CFR 408.12154(1)
Repeat$100$50Jun 29, 2016Final

Inspection 315382598 OPENED AUG 6, 2012Closed

Unprogrammed other · Partial · Health · 8 employees at the site · Closed Sep 27, 2012

34150 W 9 Mile Rd, Farmington, MI 48335 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315383786 OPENED JUL 18, 2012Closed

Planned · Complete · Safety · 8 employees at the site · Closed Jun 10, 2013

34150 W 9 Mile Rd, Farmington, MI 48335 · Plate Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$100$50Sep 17, 2012Final
Citation 1, item 1b Serious$0$0Sep 17, 2012Final
Citation 1, item 2 Serious$100$50Sep 17, 2012Final
Citation 1, item 3
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$100$50Sep 17, 2012Final
Citation 1, item 4
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$125$62Sep 17, 2012Final
Citation 1, item 5
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$125$62Sep 17, 2012Final
Citation 1, item 6
29 CFR 1910.147(c)(7)(ia) · Lockout/tagout
Serious$125$62Sep 17, 2012Final
Citation 1, item 7
29 CFR 1910.146(c)(4) · Permit-required confined spaces
Serious$125$62Sep 17, 2012Final
Citation 2, item 1 Other-than-serious$0$0Sep 17, 2012Final
Citation 2, item 2 Other-than-serious$0$0Sep 17, 2012Final
Citation 2, item 3 Other-than-serious$0$0Sep 17, 2012Final
Citation 2, item 4 Other-than-serious$0$0Sep 17, 2012Final
Citation 2, item 5 Other-than-serious$0$0Sep 17, 2012Final
Citation 2, item 6 Other-than-serious$0$0Sep 17, 2012Final
Citation 2, item 7 Other-than-serious$0$0Sep 17, 2012Final
Citation 2, item 8 Other-than-serious$0$0Sep 17, 2012Final
Citation 2, item 9
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Sep 17, 2012Final
Citation 2, item 10
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Sep 17, 2012Final
Citation 2, item 11
29 CFR 1910.107(g)(3) · Spray painting and finishing
Other-than-serious$0$0Sep 17, 2012Final
Citation 2, item 12
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Sep 17, 2012Final

Inspection 127031334 OPENED JAN 23, 2001Closed

Planned · Complete · Safety · 4 employees at the site · Closed Dec 26, 2001

7925 Beech Daly Rd, Taylor, MI 48180 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Mar 20, 2001Closed
Citation 1, item 2
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Mar 20, 2001Closed
Citation 1, item 3
29 CFR 1926.59(e)(2) · Hazard communication
Other-than-serious$0$0Mar 20, 2001Closed
Citation 1, item 4 Other-than-serious$0$0Mar 20, 2001Closed
Citation 1, item 5 Other-than-serious$0$0Mar 20, 2001Closed
Citation 1, item 6 Other-than-serious$0$0Mar 20, 2001Closed
Citation 1, item 7 Other-than-serious$0$0Mar 20, 2001Closed
Citation 1, item 8 Other-than-serious$0$0Mar 20, 2001Closed
Citation 1, item 9
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$0$0Mar 20, 2001Closed

Inspection 124855339 OPENED NOV 21, 1995Closed

Planned · Complete · Safety · 10 employees at the site · Closed Feb 15, 1996

20764 Whitlock, Farmington Hills, MI 48336 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Serious$600$600Jan 8, 1996Closed
Citation 1, item 2 Serious$450$450Jan 8, 1996Closed
Citation 1, item 3 Serious$450$450Jan 8, 1996Closed
Citation 1, item 4 Serious$450$450Jan 8, 1996Closed
Citation 1, item 5 Serious$450$450Jan 8, 1996Closed
Citation 1, item 6 Serious$450$450Jan 8, 1996Closed
Citation 1, item 7 Serious$450$450Jan 8, 1996Closed
Citation 1, item 8 Serious$600$600Jan 8, 1996Closed
Citation 1, item 9 Serious$450$450Jan 8, 1996Closed
Citation 1, item 10 Serious$450$450Jan 8, 1996Closed
Citation 1, item 11 Serious$450$450Jan 8, 1996Closed
Citation 1, item 12
29 CFR 1910.1200(h) · Hazard communication
Serious$450$450Jan 8, 1996Closed
Citation 2, item 1 Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 2 Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 3 Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 4 Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 5 Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 6 Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 7 Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 8 Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 9
29 CFR 1910.305(b)(2) · Electrical wiring methods
Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 10
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 11
29 CFR 1910.106(d)(3)(ii) · Flammable liquids
Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 12
29 CFR 1910.106(d)(3)(ii) · Flammable liquids
Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 13
29 CFR 1910.106(e)(2)(ivc) · Flammable liquids
Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 14
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Other-than-serious$0$0Jan 8, 1996Closed
Citation 2, item 15
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jan 8, 1996Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(ii)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.106(e)(2)(ivc)

(iv) Handling liquids at point of final use. (a) Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be kept in covered containers when not actually in use.

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.146 · Permit-required confined spaces

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.59 · Hazard communication

29 CFR 4080.1014

29 CFR 4081.114

29 CFR 4081.121

29 CFR 4081.1211

29 CFR 4081.1222

29 CFR 4081.1223

29 CFR 4081.125

29 CFR 4081.1854

29 CFR 4081.1872

29 CFR 4081.2042

29 CFR 4081.2154

29 CFR 4081.2166

29 CFR 4081.2631

29 CFR 4081.2635

29 CFR 4081.2641

29 CFR 4081.33

29 CFR 4081.3308

29 CFR 4081.3312

29 CFR 4081.3370

29 CFR 4081.34

29 CFR 4081.632

29 CFR 4081.645

29 CFR 4081.722

29 CFR 4081.727

29 CFR 4081.835

29 CFR 4084.114

29 CFR 4084.621

29 CFR 4084.732

29 CFR 4084.743

29 CFR 4084.761

Other plate work manufacturing employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.