OSHA SearchOSHA records by employer

American Temperature Services Inc: OSHA inspections and violations

Ann Arbor, Michigan · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

2inspections
3citation items
$2,000current penalties
Aug 12, 2024last inspection

Since 2012, OSHA inspectors have visited American Temperature Services Inc in Michigan 2 times.

The most recent inspection opened on Aug 12, 2024 on a referral, in New Hudson.

In all, OSHA issued 3 citation items: 2 serious and 1 other-than-serious.

The proposed penalties came to $4,000; today they stand at $2,000, 50% less.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. American Temperature Services Inc averages $2,000 across 1 cited inspection.

American Temperature Services Inc: OSHA citation items per year, 2012 to 2024
Citation items per year, by inspection date.

Michigan · latest 90 days of OSHA records

656employers cited

25 of them in the same industry

Get notified the morning OSHA posts each new citation in Michigan: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Michigan

Checking a subcontractor, a client or your own company? Watch American Temperature Services Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347680027 OPENED AUG 12, 2024Closed

Referral · Partial · Safety · 32 employees at the site · Closed Jan 22, 2025

30029 Research Drive, New Hudson, MI 48165 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a Serious$3,500$1,750Oct 25, 2024Final
Citation 1, item 1b
29 CFR 1910.333(a)(1) · Working near live electrical parts
Serious$0$0Oct 25, 2024Final
Citation 2, item 1
29 CFR 408.22141(1)
Other-than-serious$500$250Oct 25, 2024Final

Inspection 313334062 OPENED MAR 30, 2012Closed

Planned · Complete · Safety · 13 employees at the site · Closed Apr 3, 2012

771 Airport Blvd, Ann Arbor, MI 48108 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.332 · Training

29 CFR 1910.332(b)(1)

(b) Content of training—(1) Practices addressed in this standard. Employees shall be trained in and familiar with the safety-related work practices required by §§ 1910.331 through 1910.335 that pertain to their respective job assignments.

29 CFR 1910.333 · Working near live electrical parts

29 CFR 1910.333(a)(1)

(1) Deenergized parts. Live parts to which an employee may be exposed shall be deenergized before the employee works on or near them, unless the employer can demonstrate that deenergizing introduces additional or increased hazards or is infeasible due to equipment design or operational limitations. Live parts that operate at less than 50 volts to ground need not be deenergized if there will be no increased exposure to electrical burns or to explosion due to electric arcs.

Other electrical contractors and other wiring installation contractors employers in Michigan

Alert subscribers get notified of each newly cited employer in Michigan the morning it is posted. See the alert plans.