OSHA SearchOSHA records by employer

Ameriken Die Supply, Inc.: OSHA inspections and violations

Wood Dale, Illinois · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · NAICS 333514

2inspections
9citation items
$17,303current penalties
Aug 30, 2016last inspection

Since 2013, OSHA inspectors have visited Ameriken Die Supply, Inc. in Illinois 2 times.

The most recent inspection opened on Aug 30, 2016 as a planned inspection, in Wood Dale.

In all, OSHA issued 9 citation items: 6 serious and 3 other-than-serious.

The proposed penalties came to $31,692; today they stand at $17,303, 45% less.

The rule cited most here is 1910.147 (lockout/tagout), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Ameriken Die Supply, Inc. averages $12,403 across 1 cited inspection.

Ameriken Die Supply, Inc. also files yearly injury logs with OSHA, summarized below.

Ameriken Die Supply, Inc.: OSHA citation items per year, 2013 to 2016
Citation items per year, by inspection date.

Illinois · latest 90 days of OSHA records

421employers cited

Get notified the morning OSHA posts each new citation in Illinois: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Illinois

Checking a subcontractor, a client or your own company? Watch Ameriken Die Supply, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341736874 OPENED AUG 30, 2016Closed

Planned · Partial · Safety · 39 employees at the site · Closed Jan 13, 2017

618 N. Edgewood Ave., Wood Dale, IL 60191 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(4)(ii) · Lockout/tagout
Other-than-serious$5,487$0Oct 13, 2016Final
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$5,487$5,487Oct 13, 2016Final
Citation 1, item 3a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$8,231$4,116Oct 13, 2016Final
Citation 1, item 3b
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Serious$0$0Oct 13, 2016Final
Citation 1, item 4
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$5,487$2,800Oct 13, 2016Final

Inspection 339505968 OPENED DEC 3, 2013Closed

Planned · Partial · Safety · 79 employees at the site · Closed Feb 21, 2014

618 N. Edgewood Ave., Wood Dale, IL 60191 · Special Die and Tool, Die Set, Jig, and Fixture Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$3,500$2,450Dec 30, 2013Final
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$3,500$2,450Dec 30, 2013Final
Citation 2, item 1
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Other-than-serious$0$0Dec 30, 2013Final
Citation 2, item 2
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Dec 30, 2013Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the Wood Dale site logged 1 recordable injury or illness among about 39 workers: 2.7 per 100 full-time workers, against a median of 2.3 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
AmeriKen Die Supply, Inc
Wood Dale · 2025
39 102.72.3
Ameriken Die Supply, Inc.
Wood Dale · 2022
32 103.52.3

Included with any plan: 7 more yearly logs from these sites, back to 2017, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(4)(ii)

(ii) The procedures shall clearly and specifically outline the scope, purpose, authorization, rules, and techniques to be utilized for the control of hazardous energy, and the means to enforce compliance including, but not limited to, the following:

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other special die and tool, die set, jig, and fixture manufacturing employers in Illinois

Alert subscribers get notified of each newly cited employer in Illinois the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.