OSHA SearchOSHA records by employer

Anchorage Chrysler Center, Inc.: OSHA inspections and violations

Anchorage, Alaska · New Car Dealers · NAICS 441110

5inspections
19citation items
$7,388current penalties
Feb 15, 2024last inspection

Anchorage Chrysler Center, Inc. has 5 OSHA inspections on record in Alaska, the first in 1973.

OSHA's last visit started on Feb 15, 2024 on a referral, in Anchorage.

Across those inspections OSHA issued 19 citation items: 6 serious and 13 other-than-serious.

OSHA proposed $33,573 in penalties. After settlements and reviews the total is $7,388, down 78%.

Most often, OSHA cited 1910.107, spray painting and finishing (4 items).

For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. Anchorage Chrysler Center, Inc. averages $2,982 over 2 cited inspections in that time.

Anchorage Chrysler Center, Inc.: OSHA citation items per year, 1973 to 2024
Citation items per year, by inspection date.

Alaska · latest 90 days of OSHA records

37employers cited

Get notified the morning OSHA posts each new citation in Alaska: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Alaska

Checking a subcontractor, a client or your own company? Watch Anchorage Chrysler Center, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347326092 OPENED FEB 15, 2024Closed

Referral · Partial · Health · 120 employees at the site · Closed Apr 23, 2025

2601 East 5th Avenue, Anchorage, AK 99501 · New Car Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$14,518$3,630May 22, 2024Final
Citation 1, item 2
29 CFR 1910.151(c) · First aid and eyewash
Serious$8,296$0May 22, 2024Final

Inspection 347383234 OPENED FEB 15, 2024Closed

Referral · Partial · Safety · 120 employees at the site · Closed Feb 20, 2025

2601 East 5th Avenue, Anchorage, AK 99501 · New Car Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.132(d)(1) · Personal protective equipment, general requirements
Serious$9,334$2,334May 22, 2024Final

Inspection 310850615 OPENED APR 3, 2008Closed

Complaint · Partial · Safety · 107 employees at the site · Closed Aug 12, 2008

2601 East 5th Ave., Anchorage, AK 99501 · New Car Dealers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.132(a) · Personal protective equipment, general requirements
Serious$1,375$1,375May 6, 2008Closed
Citation 1, item 1b
29 CFR 1910.25(d)(2)(xv) · Portable wood ladders
Serious$0$0May 6, 2008Closed
Citation 1, item 1c
29 CFR 1910.25(d)(2)(xii) · Portable wood ladders
Serious$0$0May 6, 2008Closed
Citation 2, item 1
29 CFR 1910.36(g)(2) · Exit route design
Other-than-serious$0$0May 6, 2008Closed
Citation 2, item 2
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0May 6, 2008Closed
Citation 2, item 3
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Other-than-serious$0$0May 6, 2008Closed
Citation 2, item 4
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Other-than-serious$0$0May 6, 2008Closed
Citation 2, item 5
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Other-than-serious$0$0May 6, 2008Closed
Citation 2, item 6
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Other-than-serious$0$0May 6, 2008Closed
Citation 2, item 7
29 CFR 1910.305(j)(3)(i) · Electrical wiring methods
Other-than-serious$0$0May 6, 2008Closed

Inspection 218280964 OPENED MAR 14, 1974Closed

Follow-up · Complete · Safety · 50 employees at the site · Closed Mar 10, 1984

2601 East 5th Avenue, Anchorage, AK 99501 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 218285179 OPENED DEC 20, 1973Closed

Planned · Complete · Health · 50 employees at the site · Closed Mar 1, 1974

2601 E 5th, Anchorage, AK 99501 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(i) · Flammable liquids
Other-than-serious$25$25Jan 29, 1974Closed
Citation 1, item 2
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Jan 29, 1974Closed
Citation 1, item 3
29 CFR 1910.107(e)(2) · Spray painting and finishing
Other-than-serious$0$0Jan 29, 1974Contested
Citation 1, item 4
29 CFR 1910.107(e)(9) · Spray painting and finishing
Other-than-serious$0$0Jan 29, 1974Closed
Citation 1, item 5
29 CFR 1910.107(g)(7) · Spray painting and finishing
Other-than-serious$0$0Jan 29, 1974Closed
Citation 1, item 6
29 CFR 1910.134(d)(2)(ii) · Respiratory protection
Other-than-serious$25$25Jan 29, 1974Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(i)

(6) Sources of ignition—(i) General. Adequate precautions shall be taken to prevent the ignition of flammable vapors. Sources of ignition include but are not limited to open flames; lightning; smoking; cutting and welding; hot surfaces; frictional heat; static, electrical, and mechanical sparks; spontaneous ignition, including heat-producing chemical reactions; and radiant heat.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(e)(2)

(2) Quantity. The quantity of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) kept in the vicinity of spraying operations shall be the minimum required for operations and should ordinarily not exceed a supply for 1 day or one shift. Bulk storage of portable containers of flammable liquids or liquids with a flashpoint greater than 199.4 °F (93 °C) shall be in a separate, constructed building detached from other important buildings or cut off in a standard manner.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.25 · Portable wood ladders

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.36 · Exit route design

Other new car dealers employers in Alaska

Alert subscribers get notified of each newly cited employer in Alaska the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.