OSHA SearchOSHA records by employer

Anderson Heating & Air Conditioning, LLC: OSHA inspections and violations

Carson City, Nevada · Plumbing, Heating, and Air-Conditioning Contractors · NAICS 238220

9inspections
11citation items
$18,540current penalties
Nov 8, 2022last inspection

Anderson Heating & Air Conditioning, LLC has 9 OSHA inspections on record in Nevada, the first in 1997.

OSHA's last visit started on Nov 8, 2022 after a fatality or catastrophe, in Carson City.

Across those inspections OSHA issued 11 citation items: 5 serious and 6 other-than-serious.

OSHA proposed $19,125 in penalties. After settlements and reviews the total is $18,540, down 3%.

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Anderson Heating & Air Conditioning, LLC averages $8,588 over 2 cited inspections in that time.

1 inspection on this page followed a fatal incident.

Anderson Heating & Air Conditioning, LLC: OSHA citation items per year, 1997 to 2022
Citation items per year, by inspection date.

Nevada · latest 90 days of OSHA records

111employers cited

Get notified the morning OSHA posts each new citation in Nevada: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Nevada

Checking a subcontractor, a client or your own company? Watch Anderson Heating & Air Conditioning, LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 346341779 OPENED NOV 8, 2022Closed

Fatality or catastrophe · Partial · Safety · 24 employees at the site · Closed Jul 9, 2026

2578 S Curry St Suite 8, Carson City, NV 89703 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Incident on Nov 8, 2022 (fatal): Employee suffers heart attack working on hvac unit

At 12:00 noon on November 8, 2022, an employee was working as a heating and air conditioning technician and was diagnosing a mechanical problem with a heating unit located on the roof of a single-story medical facility. The employee suffered a cardiac event and died due to atherosclerotic cardiovascular disease.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$5,625$5,625Apr 26, 2023Final
Citation 1, item 2 Serious$5,625$5,625Apr 26, 2023Final
Citation 1, item 3
29 CFR NEVADA REVISED STATUTES 618.383(1
Serious$5,625$5,625Apr 26, 2023Final

Inspection 341174654 OPENED JAN 11, 2016Closed

Planned · Complete · Safety · 8 employees at the site · Closed Mar 23, 2016

340 2nd St, Reno, NV 89501 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$300$300Mar 11, 2016Final

Inspection 315791509 OPENED AUG 30, 2011Closed

Referral · Partial · Safety · 5 employees at the site · Closed Nov 15, 2011

2578 South Curry Street (suite 8), Carson City, NV 89703 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$1,950$1,365Sep 29, 2011Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Sep 29, 2011Closed
Citation 2, item 2
29 CFR 1910.303(g)(1)(ia) · Electrical equipment, general requirements
Other-than-serious$0$0Sep 29, 2011Closed
Citation 2, item 3
29 CFR 1926.503(b)(1) · Fall protection training in construction
Other-than-serious$0$0Sep 29, 2011Closed

Inspection 313118390 OPENED APR 13, 2009Closed

Planned · Complete · Safety · 8 employees at the site · Closed Apr 16, 2009

2350 Wingfield Hills Rd. (manor Care), Sparks, NV 89436 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.1060(a)(1)(iii) · Ladder and stairway training
Other-than-serious$0$0Apr 16, 2009Closed

Inspection 311352819 OPENED AUG 8, 2007Closed

Planned · Complete · Safety · 4 employees at the site · Closed Aug 9, 2007

3910 So. Carson St. (courtyard), Carson City, NV 89701 · Plumbing, Heating, and Air-Conditioning Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305111296 OPENED JUN 24, 2002Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jun 24, 2002

5 Pine Cone St., Dayton, NV 89403 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 305083032 OPENED APR 25, 2002Closed

Planned · Complete · Safety · 4 employees at the site · Closed May 17, 2002

900 So. Carson St. (carson Station Hotel/casino), Carson City, NV 89701 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Apr 25, 2002Closed

Inspection 302774278 OPENED MAY 18, 1999Closed

Planned · Complete · Safety · 4 employees at the site · Closed May 18, 1999

555 Hammill Ln., Reno, NV 89509 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

1 older inspection

Inspection 301700498 OPENED MAY 13, 1997Closed

Planned · Complete · Safety · 4 employees at the site · Closed Jun 25, 1997

3723 No. Carson St. (blockbuster Video), Carson City, NV 89703 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0May 14, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(1)

(c) General—(1) Energy control program. The employer shall establish a program consisting of energy control procedures, employee training and periodic inspections to ensure that before any employee performs any servicing or maintenance on a machine or equipment where the unexpected energizing, start up or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source, and rendered inoperative.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.212(a)(3)(ii)

(ii) The point of operation of machines whose operation exposes an employee to injury, shall be guarded. The guarding device shall be in conformity with any appropriate standards therefor, or, in the absence of applicable specific standards, shall be so designed and constructed as to prevent the operator from having any part of his body in the danger zone during the operating cycle.

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.303(g)(1)(ia)

(A) The depth of the working space in the direction of access to live parts may not be less than indicated in Table S-1. Distances shall be measured from the live parts if they are exposed or from the enclosure front or opening if they are enclosed;

29 CFR 1910.332 · Training

29 CFR 1926.1060 · Ladder and stairway training

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

29 CFR 1926.59 · Hazard communication

Other plumbing, heating, and air-conditioning contractors employers in Nevada