Inspection 348926767 OPENED MAY 6, 2026Closed
998 Hunters Trail, Anderson, SC 29625 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Anderson, South Carolina · Water Supply and Irrigation Systems · NAICS 221310
OSHA has inspected Anderson Regional Joint Water System 2 times in South Carolina since 2024.
The latest one began on May 6, 2026 to follow up on an earlier case, in Anderson.
Those inspections ended with 5 citation items: 4 serious and 1 other-than-serious.
Penalties were first proposed at $1,280 and still stand at $1,280.
Lockout/tagout comes up most often in these citations: 3 items under 1910.147.
How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Anderson Regional Joint Water System averages $1,280 (1 cited inspection).
1 inspection on this page followed a fatal incident.
Anderson Regional Joint Water System also files yearly injury logs with OSHA, summarized below.
South Carolina · latest 90 days of OSHA records
42employers cited
Get notified the morning OSHA posts each new citation in South Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in South Carolina
Checking a subcontractor, a client or your own company? Watch Anderson Regional Joint Water System and get notified the morning OSHA posts a new citation for it.
Watch this company998 Hunters Trail, Anderson, SC 29625 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
998 Hunters Trail, Anderson, SC 29625 · Water Supply and Irrigation Systems · OSHA's record · Phone and website on Google Maps
Incident on Jul 18, 2024 (fatal): Employee is electrocuted while troubleshooting ac unit
At approximately 12:00 a.m. on July 18, 2024, Employee #1 was working at the Clemson Booster Station troubleshooting AC Unit #2. While cutting a wire under the fan guard using a non-insulated wire cutter, Employee #1 came into contact with a live wire, resulting in an electrical shock. Employee #1 cied from his injuries shortly thereafter.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $400 | $400 | Jan 8, 2025 | Final |
| Citation 1, item 2 29 CFR 1910.147(c)(7)(i) · Lockout/tagout |
Serious | $300 | $300 | Jan 8, 2025 | Final |
| Citation 1, item 3 29 CFR 1910.147(d)(4)(i) · Lockout/tagout |
Serious | $280 | $280 | Jan 8, 2025 | Final |
| Citation 1, item 4 29 CFR 1910.335(a)(2)(i) · Safeguards for personnel protection |
Serious | $300 | $300 | Jan 8, 2025 | Final |
| Citation 1, item 5 29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 8, 2025 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Anderson site logged 1 recordable injury or illness among about 19 workers: 5.7 per 100 full-time workers, against a median of 3.0 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Anderson Regional Joint Water System Anderson · 2025 | 19 | 1 | 0 | 5.7 | 3.0 |
Included with any plan: 6 more yearly logs from these sites, back to 2019, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.132(d)(2)
(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.
29 CFR 1910.147(c)(4)(i)
(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.
29 CFR 1910.147(c)(7)(i)
(7) Training and communication. (i) The employer shall provide training to ensure that the purpose and function of the energy control program are understood by employees and that the knowledge and skills required for the safe application, usage, and removal of the energy controls are acquired by employees. The training shall include the following:
Alert subscribers get notified of each newly cited employer in South Carolina the morning it is posted. See the alert plans.