OSHA SearchOSHA records by employer

Andrews and Hamilton Company, Inc.: OSHA inspections and violations

Micro, North Carolina · Industrial Machinery and Equipment Merchant Wholesalers · NAICS 423830

3inspections
11citation items
$2,625current penalties
Jun 27, 2016last inspection

Since 1989, OSHA inspectors have visited Andrews and Hamilton Company, Inc. in North Carolina 3 times.

The most recent inspection opened on Jun 27, 2016 on a referral, in Lillington.

In all, OSHA issued 11 citation items: 2 serious and 9 other-than-serious.

The proposed penalties came to $3,500; today they stand at $2,625, 25% less.

The rule cited most here is 1910.1200 (hazard communication), 3 times.

Among wholesale employers, the typical cited inspection since 2015 ends with a $3,424 penalty. Andrews and Hamilton Company, Inc. averages $1,500 across 1 cited inspection.

Andrews and Hamilton Company, Inc.: OSHA citation items per year, 1989 to 2016
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

228employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Andrews and Hamilton Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341585081 OPENED JUN 27, 2016Closed

Referral · Partial · Safety · 4 employees at the site · Closed Jan 5, 2017

109 S. 8th Street, Lillington, NC 27546 · Wholesale Trade Agents and Brokers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(1) · Fall protection in construction
Serious$1,000$750Aug 19, 2016Final
Citation 1, item 2
29 CFR 1926.501(b)(4)(i) · Fall protection in construction
Serious$1,000$750Aug 19, 2016Final

Inspection 313221061 OPENED JUL 31, 2009Closed

Complaint · Partial · Health · 13 employees at the site · Closed Dec 16, 2009

3829 South Miami Blvd., Durham, NC 27703 · Industrial Machinery and Equipment Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(c)(2) · Spray painting and finishing
Other-than-serious$500$375Oct 13, 2009Closed
Citation 1, item 1b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Other-than-serious$0$0Oct 13, 2009Closed
Citation 1, item 2
29 CFR 1910.252(a)(2)(vii) · Welding fire safety
Other-than-serious$500$375Oct 13, 2009Closed
Citation 1, item 3a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$500$375Oct 13, 2009Closed
Citation 1, item 3b
29 CFR 1910.1200(g)(8) · Hazard communication
Other-than-serious$0$0Oct 13, 2009Closed
Citation 1, item 3c
29 CFR 1910.1200(h)(1)(i) · Hazard communication
Other-than-serious$0$0Oct 13, 2009Closed

Inspection 18507442 OPENED MAR 13, 1989Closed

Planned · Complete · Safety · 2 employees at the site · Closed May 26, 1989

Main Street, Micro, NC 27555 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Apr 26, 1989Closed
Citation 1, item 2
29 CFR 1926.405(g)(2)(iii) · Job-site wiring
Other-than-serious$0$0Apr 26, 1989Closed
Citation 1, item 3
29 CFR 1926.405(g)(2)(iv) · Job-site wiring
Other-than-serious$0$0Apr 26, 1989Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(2)

(2) Minimum separation. There shall be no open flame or spark producing equipment in any spraying area nor within 20 feet thereof, unless separated by a partition.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.252 · Welding fire safety

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.501 · Fall protection in construction

Other industrial machinery and equipment merchant wholesalers employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.