Inspection 347310609 OPENED FEB 28, 2024Closed
8061 Avonia Road, Fairview, PA 16415 · Other Electronic Component Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
State College, Pennsylvania · Other Electronic Component Manufacturing · NAICS 334419
OSHA has inspected Api Technologies, Inc. 7 times in Pennsylvania since 2020.
The latest one began on Feb 28, 2024 after a complaint, in Fairview.
Those inspections ended with 9 citation items: 6 serious and 3 other-than-serious.
Penalties were first proposed at $17,384 and now stand at $10,350, 40% lower after settlements or reviews.
Respiratory protection comes up most often in these citations: 4 items under 1910.134.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and Api Technologies, Inc. averages $2,070 (5 cited inspections).
Api Technologies, Inc. also files yearly injury logs with OSHA, summarized below.
Want to know if OSHA cites Api Technologies, Inc. again? Add it to a watchlist and we will email you the morning the citation shows up.
Watch this company8061 Avonia Road, Fairview, PA 16415 · Other Electronic Component Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1900 West College Avenue, State College, PA 16801 · Other Electronic Component Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.303(b)(7)(iv) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | May 2, 2023 | Final |
1900 West College Avenue, State College, PA 16801 · Other Electronic Component Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.134(k)(6) · Respiratory protection |
Other-than-serious | $0 | $0 | Mar 13, 2023 | Final |
1900 West College Avenue, State College, PA 16801 · Other Electronic Component Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Mar 13, 2023 | Final |
8061 Avonia Road, Fairview, PA 16415 · All Other Miscellaneous Electrical Equipment and Component Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
1900 West College Avenue, State College, PA 16801 · Radio and Television Broadcasting and Wireless Communications Equipment Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $8,290 | $5,850 | Aug 24, 2021 | Final |
8061 Avonia Road, Fairview, PA 16415 · All Other Miscellaneous Electrical Equipment and Component Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(c)(2)(ii) · Respiratory protection |
Serious | $4,916 | $2,250 | Apr 3, 2020 | Final |
| Citation 1, item 1b 29 CFR 1910.134(c)(2)(i) · Respiratory protection |
Serious | $0 | $0 | Apr 3, 2020 | Final |
| Citation 1, item 1c 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $0 | $0 | Apr 3, 2020 | Final |
| Citation 1, item 3a 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Serious | $4,178 | $2,250 | Apr 3, 2020 | Final |
| Citation 1, item 3b 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | Apr 3, 2020 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2021, the State College site logged 6 recordable injuries or illnesses among about 182 workers: 3.2 per 100 full-time workers, against a median of 0.5 for its industry. Those cases cost 14 days away from work.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| API Technologies State College · 2021 | 182 | 6 | 1 | 3.2 | 0.5 |
| API Technologies - Fairview Manufacturing Fairview · 2021 | 169 | 0 | 0 | 0.0 | 0.5 |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.134(c)(2)(i)
(i) An employer may provide respirators at the request of employees or permit employees to use their own respirators, if the employer determines that such respirator use will not in itself create a hazard. If the employer determines that any voluntary respirator use is permissible, the employer shall provide the respirator users with the information contained in appendix D to this section (“Information for Employees Using Respirators When Not Required Under the Standard”); and
29 CFR 1910.134(c)(2)(ii)
(ii) In addition, the employer must establish and implement those elements of a written respiratory protection program necessary to ensure that any employee using a respirator voluntarily is medically able to use that respirator, and that the respirator is cleaned, stored, and maintained so that its use does not present a health hazard to the user. Exception: Employers are not required to include in a written respiratory protection program those employees whose only use of respirators involves the voluntary use of filtering facepieces (dust masks).
29 CFR 1910.134(e)(1)
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.