OSHA SearchOSHA records by employer

Aponte Consultant Inc: OSHA inspections and violations

Mayaguez, Puerto Rico · Commercial and Institutional Building Construction · NAICS 236220

1inspections
7citation items
$1,725current penalties
Dec 8, 2015last inspection

Aponte Consultant Inc has one OSHA inspection on record in Puerto Rico.

OSHA opened it on Dec 8, 2015 on a referral, in Mayaguez.

From that inspection OSHA issued 7 citation items: 7 serious.

OSHA proposed $3,000 in penalties. After settlements and reviews the total is $1,725, down 42%.

Most often, OSHA cited 1926.451, scaffolds, general requirements (4 items).

For context, across all construction employers the median penalty per cited inspection since 2015 is $3,080. Aponte Consultant Inc averages $1,725 over 1 cited inspection in that time.

Aponte Consultant Inc: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Puerto Rico · latest 90 days of OSHA records

112employers cited

8 of them in the same industry

Get notified the morning OSHA posts each new citation in Puerto Rico: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Puerto Rico

Checking a subcontractor, a client or your own company? Watch Aponte Consultant Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341103455 OPENED DEC 8, 2015Closed

Referral · Complete · Safety · 5 employees at the site · Closed Jun 2, 2016

Mayaguez Mall Carr #2, Mayaguez, PR 00680 · Commercial and Institutional Building Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.452(c)(2) · Rules for each type of scaffold
Serious$750$375Feb 24, 2016Final
Citation 1, item 2a
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$1,500$900Feb 24, 2016Final
Citation 1, item 2b
29 CFR 1926.451(c)(2)(ii) · Scaffolds, general requirements
Serious$0$0Feb 24, 2016Final
Citation 1, item 2c
29 CFR 1926.451(f)(3) · Scaffolds, general requirements
Serious$0$0Feb 24, 2016Final
Citation 1, item 2d
29 CFR 1926.451(g)(4)(iv) · Scaffolds, general requirements
Serious$0$0Feb 24, 2016Final
Citation 1, item 3a
29 CFR 1926.454(a) · Scaffold training
Serious$750$450Feb 24, 2016Final
Citation 1, item 3b
29 CFR 1926.454(b) · Scaffold training
Serious$0$0Feb 24, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(c)(2)(ii)

(ii) Unstable objects shall not be used to support scaffolds or platform units.

29 CFR 1926.451(f)(3)

(3) Scaffolds and scaffold components shall be inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity.

29 CFR 1926.452 · Rules for each type of scaffold

29 CFR 1926.454 · Scaffold training

Other commercial and institutional building construction employers in Puerto Rico

Alert subscribers get notified of each newly cited employer in Puerto Rico the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.