Inspection 347820623 OPENED OCT 17, 2024Closed
977 Edgar Avenue, Ronceverte, WV 24970 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Ronceverte, West Virginia · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110
Since 2016, OSHA inspectors have visited Architectural Wood, LLC in West Virginia 3 times.
The most recent inspection opened on Oct 17, 2024 as a planned inspection, in Ronceverte.
In all, OSHA issued 10 citation items: 8 serious and 2 other-than-serious.
The penalties, $8,729 in total, stand where OSHA first set them.
The rule cited most here is 1910.134 (respiratory protection), 5 times.
Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Architectural Wood, LLC averages $4,364 across 2 cited inspections.
Architectural Wood, LLC also files yearly injury logs with OSHA, summarized below.
West Virginia · latest 90 days of OSHA records
28employers cited
Get notified the morning OSHA posts each new citation in West Virginia: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in West Virginia
Checking a subcontractor, a client or your own company? Watch Architectural Wood, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company977 Edgar Avenue, Ronceverte, WV 24970 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
977 Edgar Avenue, Ronceverte, WV 24970 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.151(b) · First aid and eyewash |
Other-than-serious | $0 | $0 | Sep 27, 2021 | Final |
977 Edgar Avenue, Ronceverte, WV 24970 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.134(e)(1) · Respiratory protection |
Serious | $3,741 | $3,741 | Sep 13, 2016 | Final |
| Citation 1, item 1b 29 CFR 1910.134(c)(1) · Respiratory protection |
Serious | $0 | $0 | Sep 13, 2016 | Final |
| Citation 1, item 1c 29 CFR 1910.134(f)(2) · Respiratory protection |
Serious | $0 | $0 | Sep 13, 2016 | Final |
| Citation 1, item 1d 29 CFR 1910.134(h)(1)(i) · Respiratory protection |
Serious | $0 | $0 | Sep 13, 2016 | Final |
| Citation 1, item 1e 29 CFR 1910.134(k)(1) · Respiratory protection |
Serious | $0 | $0 | Sep 13, 2016 | Final |
| Citation 1, item 2a 29 CFR 1910.147(c)(2)(ii) · Lockout/tagout |
Serious | $4,988 | $4,988 | Sep 13, 2016 | Final |
| Citation 1, item 2b 29 CFR 1910.147(c)(6)(i) · Lockout/tagout |
Serious | $0 | $0 | Sep 13, 2016 | Final |
| Citation 1, item 2c 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Serious | $0 | $0 | Sep 13, 2016 | Final |
| Citation 2, item 1 29 CFR 1910.1200(h)(3)(iv) · Hazard communication |
Other-than-serious | $0 | $0 | Sep 13, 2016 | Final |
From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.
In 2025, the Ronceverte site logged 1 recordable injury or illness among about 39 workers: 2.6 per 100 full-time workers, against a median of 4.6 for its industry.
| Site and year | Workers | Cases | Days-away cases | Rate | Industry median |
|---|---|---|---|---|---|
| Architectural Wood LLC Ronceverte · 2025 | 39 | 1 | 0 | 2.6 | 4.6 |
Included with any plan: 3 more yearly logs from these sites, back to 2021, with each site's average rate over its latest three years. Already a subscriber? Sign in.
See plansCurrent text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.1200(h)(3)(iv)
(iv) The details of the hazard communication program developed by the employer, including an explanation of the labels received on shipped containers and the workplace labeling system used by their employer; the safety data sheet, including the order of information and how employees can obtain and use the appropriate hazard information.
29 CFR 1910.134(c)(1)
(1) The test instrument must have an effective audio-warning device, or a visual-warning device in the form of a screen tracing, that indicates when the test subject fails to hold his or her breath during the test. The test must be terminated and restarted from the beginning when the test subject fails to hold his or her breath during the test. The test subject then may be refitted and retested.
29 CFR 1910.134(e)(1)
(1) General. The employer shall provide a medical evaluation to determine the employee's ability to use a respirator, before the employee is fit tested or required to use the respirator in the workplace. The employer may discontinue an employee's medical evaluations when the employee is no longer required to use a respirator.
Alert subscribers get notified of each newly cited employer in West Virginia the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.