OSHA SearchOSHA records by employer

Ashley Valley Construction, Inc.: OSHA inspections and violations

Vernal, Utah · Siding Contractors · NAICS 238170

1inspections
6citation items
$750current penalties
Feb 18, 2015last inspection

OSHA has inspected Ashley Valley Construction, Inc. once in Utah.

The inspection began on Feb 18, 2015 on a referral, in Vernal.

That inspection ended with 6 citation items: 5 serious and 1 other-than-serious.

Penalties were first proposed at $1,500 and now stand at $750, 50% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 5 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Ashley Valley Construction, Inc. averages $750 (1 cited inspection).

Ashley Valley Construction, Inc.: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

67employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch Ashley Valley Construction, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 340417849 OPENED FEB 18, 2015Closed

Referral · Partial · Safety · 8 employees at the site · Closed Apr 28, 2015

695 West Highway 40, Vernal, UT 84078 · Siding Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$1,500$750Apr 1, 2015Final
Citation 1, item 1b
29 CFR 1926.451(b)(2) · Scaffolds, general requirements
Serious$0$0Apr 1, 2015Final
Citation 1, item 1c
29 CFR 1926.451(c)(2)(iv) · Scaffolds, general requirements
Serious$0$0Apr 1, 2015Final
Citation 1, item 1d
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$0$0Apr 1, 2015Final
Citation 1, item 1e
29 CFR 1926.451(g)(3)(i) · Scaffolds, general requirements
Serious$0$0Apr 1, 2015Final
Citation 2, item 1
29 CFR 1910.178(l)(6) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Apr 1, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(6)

(6) Certification. The employer shall certify that each operator has been trained and evaluated as required by this paragraph (l). The certification shall include the name of the operator, the date of the training, the date of the evaluation, and the identity of the person(s) performing the training or evaluation.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(b)(2)

(2) Except as provided in paragraphs (b)(2)(i) and (b)(2)(ii) of this section, each scaffold platform and walkway shall be at least 18 inches (46 cm) wide.

Other siding contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.