OSHA SearchOSHA records by employer

Aspen Contracting, Inc: OSHA inspections and violations

Garner, North Carolina · Roofing Contractors · NAICS 238160

6inspections
6citation items
$17,550current penalties
May 28, 2019last inspection

OSHA has inspected Aspen Contracting, Inc 6 times in North Carolina since 2011.

The latest one began on May 28, 2019, in Garner.

Those inspections ended with 6 citation items: 6 serious.

Penalties were first proposed at $19,250 and now stand at $17,550, 9% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 3 items under 1926.501.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Aspen Contracting, Inc averages $6,300 (1 cited inspection).

Aspen Contracting, Inc: OSHA citation items per year, 2011 to 2019
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

236employers cited

18 of them in the same industry

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Aspen Contracting, Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344038047 OPENED MAY 28, 2019Closed

Unprogrammed other · Complete · Safety · 250 employees at the site · Closed Aug 28, 2019

98 Sedge Wren Ct, Garner, NC 27529 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 343899258 OPENED MAR 21, 2019Closed

Planned · Partial · Health · 1 employee at the site · Closed May 15, 2019

3314 Chase Forest Court, Matthews, NC 28105 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 317984144 OPENED APR 8, 2015Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Jul 21, 2015

151 Van Campen Blvd., Wilmington, NC 28403 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$6,300$6,300May 13, 2015Closed
Citation 1, item 1b
29 CFR 1926.20(b)(2) · Construction safety programs
Serious$0$0May 13, 2015Closed

Inspection 317719219 OPENED JUN 23, 2014Closed

Planned · Complete · Safety · 1 employee at the site · Closed Jun 25, 2014

1225 Hwy 401s, Garner, NC 27529 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 316855253 OPENED NOV 1, 2012Closed

Planned · Partial · Health · 1 employee at the site · Closed Jan 31, 2013

6330 Old Pineville Road, Charlotte, NC 28217 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(11) · Fall protection in construction
Serious$6,300$6,300Dec 4, 2012Closed

Inspection 315685149 OPENED JUL 1, 2011Closed

Unprogrammed related · Partial · Safety · 1 employee at the site · Closed Sep 19, 2011

221 Welch Avenue, Gastonia, NC 28054 · Roofing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.307(d)(1) · Mechanical power-transmission apparatus
Serious$1,050$750Aug 10, 2011Closed
Citation 1, item 1b
29 CFR 1926.307(e)(1)(i) · Mechanical power-transmission apparatus
Serious$0$0Aug 10, 2011Closed
Citation 1, item 2
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$5,600$4,200Aug 10, 2011Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1926.20 · Construction safety programs

29 CFR 1926.20(b)(2)

(2) Such programs shall provide for frequent and regular inspections of the job sites, materials, and equipment to be made by competent persons designated by the employers.

29 CFR 1926.307 · Mechanical power-transmission apparatus

29 CFR 1926.307(d)(1)

(d) Pulleys—(1) Guarding. Pulleys, any parts of which are 7 feet (2.128 m) or less from the floor or working platform, shall be guarded in accordance with the standards specified in paragraphs (m) and (o) of this section. Pulleys serving as balance wheels (e.g., punch presses) on which the point of contact between belt and pulley is more than 6 ft. 6 in. (1.976 m) from the floor or platform may be guarded with a disk covering the spokes.

29 CFR 1926.307(e)(1)(i)

(e) Belt, rope, and chain drives—(1) Horizontal belts and ropes. (i) Where both runs of horizontal belts are 7 feet (2.128 m) or less from the floor level, the guard shall extend to at least 15 inches (38.1 cm) above the belt or to a standard height except that where both runs of a horizontal belt are 42 inches (106.68 cm) or less from the floor, the belt shall be fully enclosed.

29 CFR 1926.501 · Fall protection in construction

Other roofing contractors employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.