Since 1977, OSHA inspectors have visited Asplundh Tree Expert, LLC in Delaware 10 times.
The most recent inspection opened on Sep 15, 2021 after a complaint, in Wilmington.
In all, OSHA issued 11 citation items: 5 serious and 6 other-than-serious.
The proposed penalties came to $119,506; today they stand at $40,260, 66% less.
The rule cited most here is 1910.269 (electric power generation, transmission, and distribution), 2 times.
Among staffing, cleaning and waste services employers, the typical cited inspection since 2015 ends with a $2,208 penalty. Asplundh Tree Expert, LLC averages $19,130 across 2 cited inspections.
2 inspections on this page followed a fatal incident.
It reported 1 severe injury to OSHA since 2015.
Citation items per year, by inspection date.
Delaware · latest 90 days of OSHA records
31employers cited
Get notified the morning OSHA posts each new citation in Delaware: the employer, the site address, the rules broken and the penalty.
OSHA records show Asplundh Tree Expert, LLC at 296 sites in 17 states. Together they've had 392 inspections and $775,560 in current penalties.
We match records by employer name and industry, so these sites are likely the same company, not certainly. Franchises and subsidiaries can file under one name.
Included with any plan: the site-by-site record for all 296 sites, with repeat and willful violations and citations per year for the whole company. Already a subscriber? Sign in.
Incident on Aug 2, 2018 (fatal): Employee hits energized power line with chain saw and is ele
At 2:30 p.m. on August 2, 2018, an employee was trimming a tree using a limb puller, gas powered chain saw, and extension tree trimmer. The employee came in to contact with an overhead energized 12kv power line and was electrocuted.
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Sep 8, 2021, Wilmington: Hospitalization · fractures and other injuries, unspecified · multiple trunk locations
An employee was in a tree, cutting off the top. The tree shook and the employee's safety line hopped over where the cut was made. The employee fell to the ground, suffering pelvis and rib fractures and a spine injury.
The rules behind these citations
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
(ii) Designed, installed, and used, under the supervision of qualified person, as part of a complete personal fall protection system that maintains a safety factor of at least two.
(b) In the absence of an infirmary, clinic, or hospital in near proximity to the workplace which is used for the treatment of all injured employees, a person or persons shall be adequately trained to render first aid. Adequate first aid supplies shall be readily available.
29 CFR 1910.269 · Electric power generation, transmission, and distribution
29 CFR 1910.269(c)(2)
(2) Subjects to be covered. The briefing shall cover at least the following subjects: hazards associated with the job, work procedures involved, special precautions, energy-source controls, and personal protective equipment requirements.
Alert subscribers get notified of each newly cited employer in Delaware the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.