OSHA SearchOSHA records by employer

Atlantic Plywood Corporation: OSHA inspections and violations

South Royalton, Vermont · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · NAICS 423310

1inspections
7citation items
$6,000current penalties
Mar 7, 2016last inspection

OSHA inspectors have visited Atlantic Plywood Corporation in Vermont one time.

It opened on Mar 7, 2016 after a complaint, in South Royalton.

In all, OSHA issued 7 citation items: 7 serious.

The proposed penalties came to $12,600; today they stand at $6,000, 52% less.

The rule cited most here is 1910.106 (flammable liquids), 4 times.

Among wholesale employers, the typical cited inspection since 2015 ends with a $3,424 penalty. Atlantic Plywood Corporation averages $6,000 across 1 cited inspection.

Atlantic Plywood Corporation also files yearly injury logs with OSHA, summarized below.

Atlantic Plywood Corporation: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Vermont · latest 90 days of OSHA records

29employers cited

Get notified the morning OSHA posts each new citation in Vermont: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Vermont

Checking a subcontractor, a client or your own company? Watch Atlantic Plywood Corporation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341304970 OPENED MAR 7, 2016Closed

Complaint · Partial · Health · 8 employees at the site · Closed Nov 18, 2016

5319 Vt Route 14, South Royalton, VT 05068 · Lumber, Plywood, Millwork, and Wood Panel Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.110(f)(2)(i) · Storage and handling of liquefied petroleum gases
Serious$3,600$2,000May 24, 2016Final
Citation 1, item 1b
29 CFR 1910.110(f)(5)(iii) · Storage and handling of liquefied petroleum gases
Serious$0$0May 24, 2016Final
Citation 1, item 2a
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$3,600$2,000May 24, 2016Final
Citation 1, item 3
29 CFR 1910.106(d)(7)(i)(a) · Flammable liquids
Serious$2,700$1,000May 24, 2016Final
Citation 1, item 4a
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$2,700$1,000May 24, 2016Final
Citation 1, item 4b
29 CFR 1910.106(d)(4)(iii) · Flammable liquids
Serious$0$0May 24, 2016Final
Citation 1, item 4c
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$0$0May 24, 2016Final

Injury and illness logs

From the Form 300A summaries employers file with OSHA each year. Rate = recordable cases per 100 full-time workers.

In 2025, the South Royalton site logged 0 recordable injuries or illnesses among about 9 workers: 0.0 per 100 full-time workers, against a median of 3.5 for its industry.

Site and yearWorkersCasesDays-away casesRateIndustry median
Atlantic Plywood Corp 117
South Royalton · 2025
9 000.03.5

Included with any plan: 2 more yearly logs from these sites, back to 2023, with each site's average rate over its latest three years. Already a subscriber? Sign in.

See plans

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iii)

(iii) Wiring. Electrical wiring and equipment located in inside storage rooms used for Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall be approved under subpart S of this part for Class I, Division 2 Hazardous Locations; for Category 3 flammable liquids with a flashpoint at or above 100 °F (37.8 °C) and Category 4 flammable liquids, shall be approved for general use.

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

Other lumber, plywood, millwork, and wood panel merchant wholesalers employers in Vermont

Alert subscribers get notified of each newly cited employer in Vermont the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.