OSHA SearchOSHA records by employer

B & E Auto Service Inc.: OSHA inspections and violations

Virginia Beach, Virginia · Automotive Body, Paint, and Interior Repair and Maintenance · NAICS 811121

6inspections
34citation items
$2,027current penalties
Dec 6, 2016last inspection

OSHA has inspected B & E Auto Service Inc. 6 times in Virginia since 1997.

The latest one began on Dec 6, 2016, in Virginia Beach.

Those inspections ended with 34 citation items: 24 serious and 10 other-than-serious.

Penalties were first proposed at $2,485 and now stand at $2,027, 18% lower after settlements or reviews.

Portable fire extinguishers comes up most often in these citations: 7 items under 1910.157.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and B & E Auto Service Inc. averages $882 (1 cited inspection).

B & E Auto Service Inc.: OSHA citation items per year, 1997 to 2016
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

249employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch B & E Auto Service Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341953164 OPENED DEC 6, 2016Closed

Unprogrammed other · No inspection · Safety · 12 employees at the site · Closed Dec 6, 2016

5018 Euclid Rd, Virginia Beach, VA 23462 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 340739473 OPENED JUN 29, 2015Closed

Planned · Partial · Health · 12 employees at the site · Closed Nov 12, 2015

5018 Euclid Rd, Virginia Beach, VA 23462 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(2) · Spray painting and finishing
Serious$420$294Sep 8, 2015Final
Citation 1, item 1b
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$0$0Sep 8, 2015Final
Citation 1, item 2a
29 CFR 1910.134(d)(1)(i) · Respiratory protection
Serious$420$294Sep 8, 2015Final
Citation 1, item 2b
29 CFR 1910.134(d)(1)(iii) · Respiratory protection
Serious$0$0Sep 8, 2015Final
Citation 1, item 3a
29 CFR 1910.303(b)(1) · Electrical equipment, general requirements
Serious$420$294Sep 8, 2015Final
Citation 1, item 3b
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$0$0Sep 8, 2015Final
Citation 1, item 3c
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$0$0Sep 8, 2015Final
Citation 1, item 3d
29 CFR 1910.305(g)(1)(iv)(b) · Electrical wiring methods
Serious$0$0Sep 8, 2015Final
Citation 1, item 3e
29 CFR 1910.305(g)(1)(iv)(d) · Electrical wiring methods
Serious$0$0Sep 8, 2015Final
Citation 1, item 3f
29 CFR 1910.334(a)(2) · Using electrical equipment
Serious$0$0Sep 8, 2015Final
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Sep 8, 2015Final

Inspection 312388986 OPENED JUL 16, 2008Closed

Planned · Complete · Health · 12 employees at the site · Closed Nov 14, 2008

5018 Euclid Road, Virginia Beach, VA 23462 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$225$225Sep 16, 2008Closed
Citation 1, item 1b
29 CFR 1910.134(f)(2) · Respiratory protection
Serious$0$0Sep 16, 2008Closed
Citation 1, item 2
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Serious$225$225Sep 16, 2008Closed
Citation 1, item 3
29 CFR 1910.305(a)(2)(x) · Electrical wiring methods
Serious$375$375Sep 16, 2008Closed
Citation 2, item 1
29 CFR 1910.133(a)(1) · Eye and face protection
Other-than-serious$0$0Sep 16, 2008Closed
Citation 2, item 2
29 CFR 1910.212(a)(5) · Machine guarding
Other-than-serious$0$0Sep 16, 2008Closed

Inspection 306819376 OPENED OCT 31, 2003Closed

Planned · Complete · Health · 12 employees at the site · Closed Feb 25, 2004

5018 Euclid Road, Virginia Beach, VA 23462 · Automotive Body, Paint, and Interior Repair and Maintenance · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$100$60Nov 25, 2003Closed
Citation 1, item 2a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Serious$100$60Nov 25, 2003Closed
Citation 1, item 2b
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Serious$0$0Nov 25, 2003Closed
Citation 1, item 2c
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Serious$0$0Nov 25, 2003Closed
Citation 1, item 2d
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$0$0Nov 25, 2003Closed
Citation 2, item 1
29 CFR 1910.107(b)(9) · Spray painting and finishing
Other-than-serious$0$0Nov 25, 2003Closed
Citation 2, item 2
29 CFR 1910.147(c)(7)(i) · Lockout/tagout
Other-than-serious$0$0Nov 25, 2003Closed
Citation 2, item 3
29 CFR 1910.1200(e)(1)(i) · Hazard communication
Other-than-serious$0$0Nov 25, 2003Closed

Inspection 300666740 OPENED SEP 30, 1998Closed

Follow-up · Partial · Safety · 8 employees at the site · Closed Sep 30, 1998

5018 Euclid Road, Virginia Beach, VA 23462 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 301797353 OPENED JUL 7, 1997Closed

Planned · Complete · Safety · 8 employees at the site · Closed Feb 9, 1998

5018 Euclid Road, Virginia Beach, VA 23462 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.212(a)(5) · Machine guarding
Serious$100$100Sep 29, 1997Closed
Citation 1, item 1b
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Sep 29, 1997Closed
Citation 1, item 1c
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Sep 29, 1997Closed
Citation 1, item 2a
29 CFR 1910.304(f)(4) · Grounding and circuit protection
Serious$100$100Sep 29, 1997Closed
Citation 1, item 2b
29 CFR 1910.305(b)(1) · Electrical wiring methods
Serious$0$0Sep 29, 1997Closed
Citation 2, item 1
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Sep 29, 1997Closed
Citation 2, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Sep 29, 1997Closed
Citation 2, item 3a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Sep 29, 1997Closed
Citation 2, item 3b
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Other-than-serious$0$0Sep 29, 1997Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(2)

(2) Interiors. The interior surfaces of spray booths shall be smooth and continuous without edges and otherwise designed to prevent pocketing of residues and facilitate cleaning and washing without injury.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.212 · Machine guarding

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other automotive body, paint, and interior repair and maintenance employers in Virginia

Alert subscribers get notified of each newly cited employer in Virginia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.