OSHA SearchOSHA records by employer

B. Christopher Builders Inc: OSHA inspections and violations

Kaysville, Utah · Framing Contractors · NAICS 238130

4inspections
9citation items
$10,375current penalties
Dec 11, 2019last inspection

Since 2012, OSHA inspectors have visited B. Christopher Builders Inc in Utah 4 times.

The most recent inspection opened on Dec 11, 2019 after an accident, in Farmington.

In all, OSHA issued 9 citation items: 6 serious, 2 repeat and 1 other-than-serious.

The proposed penalties came to $12,500; today they stand at $10,375, 17% less.

The rule cited most here is 1926.451 (scaffolds, general requirements), 3 times.

Among construction employers, the typical cited inspection since 2015 ends with a $3,080 penalty. B. Christopher Builders Inc averages $4,688 across 2 cited inspections.

B. Christopher Builders Inc: OSHA citation items per year, 2012 to 2019
Citation items per year, by inspection date.

Utah · latest 90 days of OSHA records

68employers cited

Get notified the morning OSHA posts each new citation in Utah: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Utah

Checking a subcontractor, a client or your own company? Watch B. Christopher Builders Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 344505060 OPENED DEC 11, 2019Closed

Accident · Partial · Safety · 9 employees at the site · Closed Feb 20, 2020

231 N Flag Rock Dr, Farmington, UT 84025 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.451(a)(6) · Scaffolds, general requirements
Serious$1,500$750Jan 2, 2020Final
Citation 1, item 1b
29 CFR 1926.451(c)(2)(v) · Scaffolds, general requirements
Serious$0$0Jan 2, 2020Final
Citation 1, item 1c
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$0$0Jan 2, 2020Final

Inspection 340525161 OPENED APR 7, 2015Closed

Planned · Partial · Safety · 13 employees at the site · Closed Nov 20, 2015

1979 Heritage Drive, Farr West, UT 84404 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(13) · Fall protection in construction
Repeat$4,000$4,000May 7, 2015Final
Citation 1, item 2
29 CFR 1926.503(a)(1) · Fall protection training in construction
Repeat$4,000$4,000May 7, 2015Final
Citation 2, item 1
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$1,000$625May 7, 2015Final

Inspection 316931336 OPENED MAY 1, 2013Closed

Planned · Partial · Safety · 8 employees at the site · Closed May 1, 2013

Berkley St. & Parley Terrace, Salt Lake City, UT 84104 · New Single-Family Housing Construction (except For-Sale Builders) · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 315880955 OPENED NOV 2, 2012Closed

Referral · Partial · Safety · 15 employees at the site · Closed Dec 13, 2012

1584 Green Rd, Kaysville, UT 84037 · Framing Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1926.501(b)(13) · Fall protection in construction
Serious$1,500$750Nov 30, 2012Closed
Citation 1, item 1b
29 CFR 1926.503(a)(1) · Fall protection training in construction
Serious$0$0Nov 30, 2012Closed
Citation 2, item 1
29 CFR 10005 C01
Other-than-serious$500$250Nov 30, 2012Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(a)(6)

(6) Scaffolds shall be designed by a qualified person and shall be constructed and loaded in accordance with that design. Non-mandatory appendix A to this subpart contains examples of criteria that will enable an employer to comply with paragraph (a) of this section.

29 CFR 1926.451(c)(2)(v)

(v) Fork-lifts shall not be used to support scaffold platforms unless the entire platform is attached to the fork and the fork-lift is not moved horizontally while the platform is occupied.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other framing contractors employers in Utah

Alert subscribers get notified of each newly cited employer in Utah the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.