OSHA SearchOSHA records by employer

B - N Sheet Metal Inc: OSHA inspections and violations

Wyoming, Minnesota · Sheet Metal Work Manufacturing · NAICS 332322

3inspections
9citation items
$2,198current penalties
Oct 7, 2025last inspection

OSHA has inspected B - N Sheet Metal Inc 3 times in Minnesota since 2015.

The latest one began on Oct 7, 2025 as a planned inspection, in Wyoming.

Those inspections ended with 9 citation items: 5 serious and 4 other-than-serious.

Penalties were first proposed at $3,425 and now stand at $2,198, 36% lower after settlements or reviews.

Machine guarding comes up most often in these citations: 2 items under 1910.212.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $3,600, and B - N Sheet Metal Inc averages $732 (3 cited inspections).

B - N Sheet Metal Inc: OSHA citation items per year, 2015 to 2025
Citation items per year, by inspection date.

Minnesota · latest 90 days of OSHA records

369employers cited

6 of them in the same industry

Get notified the morning OSHA posts each new citation in Minnesota: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Minnesota

Checking a subcontractor, a client or your own company? Watch B - N Sheet Metal Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348543893 OPENED OCT 7, 2025Closed

Planned · Complete · Safety · 29 employees at the site · Closed Nov 12, 2025

26564 Faxton Ave, Wyoming, MN 55092 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$600$360Oct 14, 2025Final
Citation 1, item 2
29 CFR 1910.304(g)(5) · Grounding and circuit protection
Serious$1,000$600Oct 14, 2025Final
Citation 2, item 1
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$200$120Oct 14, 2025Final
Citation 2, item 2
29 CFR 1910.334(a)(2)(ii) · Using electrical equipment
Other-than-serious$200$120Oct 14, 2025Final

Inspection 343535142 OPENED OCT 15, 2018Closed

Planned · Complete · Safety · 35 employees at the site · Closed Jan 24, 2019

26564 Faxton Ave, Wyoming, MN 55092 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$700$490Oct 31, 2018Final
Citation 1, item 2
29 CFR 1910.242(b) · Hand and power tools
Serious$300$210Oct 31, 2018Final
Citation 2, item 1
29 CFR 1910.134(a)(2) · Respiratory protection
Other-than-serious$100$70Oct 31, 2018Final

Inspection 341151900 OPENED DEC 8, 2015Closed

Planned · Complete · Health · 25 employees at the site · Closed Jan 22, 2016

26564 Faxton Ave, Wyoming, MN 55092 · Sheet Metal Work Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.110(e)(4)(iii) · Storage and handling of liquefied petroleum gases
Serious$225$158Dec 30, 2015Final
Citation 2, item 1
29 CFR 1910.1026(d)(1) · Hexavalent chromium
Other-than-serious$100$70Dec 30, 2015Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1026 · Hexavalent chromium

29 CFR 1910.1026(d)(1)

(d) Exposure determination—(1) General. Each employer who has a workplace or work operation covered by this section shall determine the 8-hour TWA exposure for each employee exposed to chromium (VI). This determination shall be made in accordance with either paragraph (d)(2) or paragraph (d)(3) of this section.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(e)(4)(iii)

(iii) Permanent and removable fuel containers shall be securely mounted to prevent jarring loose, slipping, or rotating, and the fastenings shall be designed and constructed to withstand static loading in any direction equal to twice the weight of the tank and attachments when filled with fuel using a safety factor of not less than four based on the ultimate strength of the material to be used. Field welding, when necessary, shall be made only on saddle plates, lugs or brackets, originally attached to the container by the tank manufacturer.

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.134(a)(2)

(2) The CNP system defaults selected for test pressure shall be set at −15 mm of water (-0.58 inches of water) and the modeled inspiratory flow rate shall be 53.8 liters per minute for performing fit tests.

29 CFR 1910.212 · Machine guarding

29 CFR 1910.242 · Hand and power tools

29 CFR 1910.304 · Grounding and circuit protection

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.334 · Using electrical equipment

Other sheet metal work manufacturing employers in Minnesota

Alert subscribers get notified of each newly cited employer in Minnesota the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.