OSHA SearchOSHA records by employer

Barney Family Enterprises LLC: OSHA inspections and violations

Wakefield, Virginia · Paint and Coating Manufacturing · NAICS 325510

1inspections
10citation items
$3,933current penalties
Dec 28, 2016last inspection

Barney Family Enterprises LLC has one OSHA inspection on record in Virginia.

OSHA opened it on Dec 28, 2016 after a complaint, in Wakefield.

From that inspection OSHA issued 10 citation items: 9 serious and 1 other-than-serious.

OSHA proposed $9,720 in penalties. After settlements and reviews the total is $3,933, down 60%.

Most often, OSHA cited 1910.106, flammable liquids (4 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $4,500. Barney Family Enterprises LLC averages $3,933 over 1 cited inspection in that time.

Barney Family Enterprises LLC: OSHA citation items per year, 2016 to 2016
Citation items per year, by inspection date.

Virginia · latest 90 days of OSHA records

251employers cited

Get notified the morning OSHA posts each new citation in Virginia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Virginia

Checking a subcontractor, a client or your own company? Watch Barney Family Enterprises LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341996338 OPENED DEC 28, 2016Closed

Complaint · Partial · Health · 3 employees at the site · Closed Jun 26, 2017

237 W. Main St., Wakefield, VA 23888 · Paint and Coating Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(d)(4)(i) · Flammable liquids
Serious$1,440$720Mar 21, 2017Final
Citation 1, item 1b
29 CFR 1910.106(d)(4)(iv) · Flammable liquids
Serious$1,440$0Mar 21, 2017Final
Citation 1, item 1c
29 CFR 1910.106(e)(3)(iv)(a) · Flammable liquids
Serious$990$0Mar 21, 2017Final
Citation 1, item 5a
29 CFR 1910.106(e)(7)(i)(b) · Flammable liquids
Serious$1,440$1,008Mar 21, 2017Final
Citation 1, item 5b
29 CFR 1910.307(c) · Hazardous (classified) locations
Serious$0$0Mar 21, 2017Final
Citation 1, item 7
29 CFR 1910.151(c) · First aid and eyewash
Serious$1,710$855Mar 21, 2017Final
Citation 1, item 8a
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$990$495Mar 21, 2017Final
Citation 1, item 8b
29 CFR 1910.178(q)(7) · Forklifts and other powered industrial trucks
Serious$0$0Mar 21, 2017Final
Citation 1, item 11
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,710$855Mar 21, 2017Final
Citation 2, item 1
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Mar 21, 2017Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(4)(i)

(4) Design and construction of inside storage rooms—(i) Construction. Inside storage rooms shall be constructed to meet the required fire-resistive rating for their use. Such construction shall comply with the test specifications set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969. Where an automatic sprinkler system is provided, the system shall be designed and installed in an acceptable manner. Openings to other rooms or buildings shall be provided with noncombustible liquid-tight raised sills or ramps at least 4 inches in height, or the floor in the storage area shall be at least 4 inches below the surrounding floor. Openings shall be provided with approved self-closing fire doors. The room shall be liquid-tight where the walls join the floor. A permissible alternate to the sill or ramp is an open-grated trench inside of the room which dra

29 CFR 1910.106(d)(4)(iv)

(iv) Ventilation. Every inside storage room shall be provided with either a gravity or a mechanical exhaust ventilation system. Such system shall be designed to provide for a complete change of air within the room at least six times per hour. If a mechanical exhaust system is used, it shall be controlled by a switch located outside of the door. The ventilating equipment and any lighting fixtures shall be operated by the same switch. A pilot light shall be installed adjacent to the switch if Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), are dispensed within the room. Where gravity ventilation is provided, the fresh air intake, as well as the exhaust outlet from the room, shall be on the exterior of the building in which the room is located.

29 CFR 1910.106(e)(3)(iv)(a)

(iv) Drainage. (a) Emergency drainage systems shall be provided to direct flammable liquid leakage and fire protection water to a safe location. This may require curbs, scuppers, or special drainage systems to control the spread of fire; see paragraph (b)(2)(vii)(b) of this section.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.151 · First aid and eyewash

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.307 · Hazardous (classified) locations