OSHA SearchOSHA records by employer

BC Granite and Marble Inc.: OSHA inspections and violations

Fort Collins, Colorado · Cut Stone and Stone Product Manufacturing · NAICS 327991

4inspections
18citation items
$5,990current penalties
Jan 21, 2026last inspection

OSHA has inspected BC Granite and Marble Inc. 4 times in Colorado since 2004.

The latest one began on Jan 21, 2026 as a planned inspection, in Fort Collins.

Those inspections ended with 18 citation items: 13 serious and 5 other-than-serious.

Penalties were first proposed at $9,984 and now stand at $5,990, 40% lower after settlements or reviews.

Respiratory protection comes up most often in these citations: 5 items under 1910.134.

How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and BC Granite and Marble Inc. averages $2,894 (1 cited inspection).

BC Granite and Marble Inc.: OSHA citation items per year, 2004 to 2026
Citation items per year, by inspection date.

Colorado · latest 90 days of OSHA records

142employers cited

Get notified the morning OSHA posts each new citation in Colorado: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Colorado

Checking a subcontractor, a client or your own company? Watch BC Granite and Marble Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 348699778 OPENED JAN 21, 2026Closed

Planned · Partial · Health · 7 employees at the site · Closed Sep 1, 2026

1833 E Harmony Rd., #11, Fort Collins, CO 80528 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$2,412$1,447Apr 2, 2026Final
Citation 1, item 2
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$2,412$1,447Apr 2, 2026Final

Inspection 335506002 OPENED AUG 1, 2012Closed

Planned · Partial · Health · 8 employees at the site · Closed Oct 24, 2012

1874 E Harmony Rd., #8, Fort Collins, CO 80528 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.133(a)(3) · Eye and face protection
Other-than-serious$1,020$612Sep 21, 2012Final
Citation 1, item 2
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$1,020$612Sep 21, 2012Final
Citation 1, item 3a
29 CFR 1910.303(g)(1)(i)(a) · Electrical equipment, general requirements
Serious$1,020$612Sep 21, 2012Final
Citation 1, item 3b
29 CFR 1910.305(g)(1)(iv)(a) · Electrical wiring methods
Serious$0$0Sep 21, 2012Final
Citation 2, item 1
29 CFR 1910.106(d)(3)(ii) · Flammable liquids
Other-than-serious$0$0Sep 21, 2012Final
Citation 2, item 2
29 CFR 1910.136(a) · Foot protection
Other-than-serious$0$0Sep 21, 2012Final

Inspection 309005932 OPENED AUG 16, 2006Closed

Follow-up · Partial · Health · 8 employees at the site · Closed Sep 22, 2006

1833 E. Harmony Rd. #8, Fort Collins, CO 80528 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 307525014 OPENED SEP 14, 2004Closed

Planned · Complete · Health · 9 employees at the site · Closed Jun 13, 2005

1833 E. Harmony Rd. #8, Fort Collins, CO 80528 · Cut Stone and Stone Product Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes
Serious$300$180Oct 20, 2004Closed
Citation 1, item 2a
29 CFR 1910.134(c)(1) · Respiratory protection
Serious$1,500$900Oct 20, 2004Closed
Citation 1, item 2b
29 CFR 1910.134(e)(1) · Respiratory protection
Serious$0$0Oct 20, 2004Closed
Citation 1, item 2c
29 CFR 1910.134(f)(1) · Respiratory protection
Serious$0$0Oct 20, 2004Closed
Citation 1, item 2d
29 CFR 1910.134(k)(1) · Respiratory protection
Serious$0$0Oct 20, 2004Closed
Citation 1, item 2e
29 CFR 1910.1000(c) · Air contaminants
Serious$0$0Oct 20, 2004Closed
Citation 1, item 2f
29 CFR 1910.1000(e) · Air contaminants
Serious$0$0Oct 20, 2004Closed
Citation 1, item 3
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$300$180Oct 20, 2004Closed
Citation 2, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Oct 20, 2004Closed
Citation 2, item 3
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Oct 20, 2004Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.1000 · Air contaminants

29 CFR 1910.1000(c)

(c) Table Z-3. An employee's exposure to any substance listed in Table Z-3, in any 8-hour work shift of a 40-hour work week, shall not exceed the 8-hour time weighted average limit given for that substance in the table.

29 CFR 1910.1000(e)

(e) To achieve compliance with paragraphs (a) through (d) of this section, administrative or engineering controls must first be determined and implemented whenever feasible. When such controls are not feasible to achieve full compliance, protective equipment or any other protective measures shall be used to keep the exposure of employees to air contaminants within the limits prescribed in this section. Any equipment and/or technical measures used for this purpose must be approved for each particular use by a competent industrial hygienist or other technically qualified person. Whenever respirators are used, their use shall comply with 1910.134.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(d)(3)(ii)

(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.133 · Eye and face protection

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.136 · Foot protection

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other cut stone and stone product manufacturing employers in Colorado

Alert subscribers get notified of each newly cited employer in Colorado the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.