OSHA SearchOSHA records by employer

Bear Plastering & Stone Installation: OSHA inspections and violations

Pecos, Texas · Drywall and Insulation Contractors · NAICS 238310

1inspections
5citation items
$12,518current penalties
Nov 30, 2023last inspection

OSHA has inspected Bear Plastering & Stone Installation once in Texas.

The inspection began on Nov 30, 2023, in Pecos; the case is still open.

That inspection ended with 5 citation items: 4 serious and 1 other-than-serious.

Penalties were first proposed at $21,057 and now stand at $12,518, 41% lower after settlements or reviews.

Scaffolds, general requirements comes up most often in these citations: 3 items under 1926.451.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Bear Plastering & Stone Installation averages $12,518 (1 cited inspection).

Bear Plastering & Stone Installation: OSHA citation items per year, 2023 to 2023
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

393employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Bear Plastering & Stone Installation and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347138497 OPENED NOV 30, 2023Open

Unprogrammed other · Partial · Safety · 11 employees at the site · Open

1507 S. Willow St., Pecos, TX 79772 · Drywall and Insulation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.451(c)(2) · Scaffolds, general requirements
Serious$5,358$3,000Dec 15, 2023Final
Citation 1, item 2
29 CFR 1926.451(e)(1) · Scaffolds, general requirements
Serious$4,465$3,000Dec 15, 2023Final
Citation 1, item 3
29 CFR 1926.451(g)(1) · Scaffolds, general requirements
Serious$5,358$3,000Dec 15, 2023Final
Citation 1, item 4
29 CFR 1926.454(c)(3) · Scaffold training
Serious$5,358$3,000Dec 15, 2023Final
Citation 2, item 1
29 CFR 1903.19(d)(1) · Proving cited hazards were fixed
Other-than-serious$518$518Mar 29, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1903.19 · Proving cited hazards were fixed

29 CFR 1903.19(d)(1)

(d) Abatement documentation. (1) The employer must submit to the Agency, along with the information on abatement certification required by paragraph (c)(3) of this section, documents demonstrating that abatement is complete for each willful or repeat violation and for any serious violation for which the Agency indicates in the citation that such abatement documentation is required.

29 CFR 1926.451 · Scaffolds, general requirements

29 CFR 1926.451(c)(2)

(2) Supported scaffold poles, legs, posts, frames, and uprights shall bear on base plates and mud sills or other adequate firm foundation.

29 CFR 1926.451(e)(1)

(1) When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access.

29 CFR 1926.454 · Scaffold training

Other drywall and insulation contractors employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.