OSHA SearchOSHA records by employer

Bennett Distributing Company, Inc.: OSHA inspections and violations

Salisbury, North Carolina · Beer and Ale Merchant Wholesalers · NAICS 424810

4inspections
21citation items
$3,315current penalties
Feb 20, 2018last inspection

OSHA has inspected Bennett Distributing Company, Inc. 4 times in North Carolina since 2003.

The latest one began on Feb 20, 2018 to follow up on an earlier case, in Salisbury.

Those inspections ended with 21 citation items: 5 serious and 16 other-than-serious.

Penalties were first proposed at $5,100 and now stand at $3,315, 35% lower after settlements or reviews.

Portable fire extinguishers comes up most often in these citations: 6 items under 1910.157.

How that compares: the median penalty per cited inspection for wholesale employers since 2015 is $3,425, and Bennett Distributing Company, Inc. averages $3,315 (1 cited inspection).

Bennett Distributing Company, Inc.: OSHA citation items per year, 2003 to 2018
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Bennett Distributing Company, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 342960051 OPENED FEB 20, 2018Closed

Follow-up · Partial · Safety · 19 employees at the site · Closed Feb 27, 2018

320 Circle M Dr, Salisbury, NC 28147 · Wine and Distilled Alcoholic Beverage Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 342444437 OPENED JUL 3, 2017Closed

Complaint · Partial · Safety · 15 employees at the site · Closed Oct 30, 2017

320 Circle M Dr, Salisbury, NC 28147 · Wine and Distilled Alcoholic Beverage Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.22(d)(2) · Walking-working surfaces
Serious$1,000$650Jul 25, 2017Final
Citation 1, item 2a
29 CFR 1910.26(c) · Dockboards
Serious$1,000$650Jul 25, 2017Final
Citation 1, item 2b
29 CFR 1910.26(a) · Dockboards
Serious$0$0Jul 25, 2017Final
Citation 1, item 3
29 CFR 1910.176(a) · Material storage and aisles
Serious$1,000$650Jul 25, 2017Final
Citation 1, item 4
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$2,100$1,365Jul 25, 2017Final

Inspection 312327182 OPENED MAY 23, 2008Closed

Planned · Complete · Safety · 10 employees at the site · Closed Jul 23, 2008

320 Circle M Dr., Salisbury, NC 28145 · Beer and Ale Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.110(f)(2)(i) · Storage and handling of liquefied petroleum gases
Other-than-serious$0$0Jun 20, 2008Closed
Citation 1, item 2a
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Jun 20, 2008Closed
Citation 1, item 2b
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Jun 20, 2008Closed
Citation 1, item 2c
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Jun 20, 2008Closed

Inspection 306291816 OPENED JAN 30, 2003Closed

Planned · Complete · Safety · 10 employees at the site · Closed Mar 28, 2003

320 Circle M Dr., Salisbury, NC 28145 · Beer and Ale Merchant Wholesalers · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7F0102
Other-than-serious$0$0Feb 6, 2003Closed
Citation 1, item 2
29 CFR 7F0102
Other-than-serious$0$0Feb 6, 2003Closed
Citation 1, item 3
29 CFR 1910.22(b)(1) · General requirements
Other-than-serious$0$0Feb 6, 2003Closed
Citation 1, item 4
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Feb 6, 2003Closed
Citation 1, item 5
29 CFR 1910.23(e)(1) · Guarding floor and wall openings and holes
Other-than-serious$0$0Feb 6, 2003Closed
Citation 1, item 6
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$0$0Feb 6, 2003Closed
Citation 1, item 7
29 CFR 1910.157(c)(1) · Portable fire extinguishers
Other-than-serious$0$0Feb 6, 2003Closed
Citation 1, item 8
29 CFR 1910.157(c)(4) · Portable fire extinguishers
Other-than-serious$0$0Feb 6, 2003Closed
Citation 1, item 9
29 CFR 1910.157(e)(1) · Portable fire extinguishers
Other-than-serious$0$0Feb 6, 2003Closed
Citation 1, item 10
29 CFR 1910.303(f) · Electrical equipment, general requirements
Other-than-serious$0$0Feb 6, 2003Closed
Citation 1, item 11
29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods
Other-than-serious$0$0Feb 6, 2003Closed
Citation 1, item 12
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Feb 6, 2003Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.110 · Storage and handling of liquefied petroleum gases

29 CFR 1910.110(f)(2)(i)

(2) General. (i) Containers in storage shall be located so as to minimize exposure to excessive temperature rise, physical damage, or tampering by unauthorized persons.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.1200(e)(1)

(e) Written hazard communication program. (1) Employers shall develop, implement, and maintain at each workplace, a written hazard communication program which at least describes how the criteria specified in paragraphs (f), (g), and (h) of this section for labels and other forms of warning, safety data sheets, and employee information and training will be met, and which also includes the following:

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.132(d)(2)

(2) The employer shall verify that the required workplace hazard assessment has been performed through a written certification that identifies the workplace evaluated; the person certifying that the evaluation has been performed; the date(s) of the hazard assessment; and, which identifies the document as a certification of hazard assessment.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.22 · Walking-working surfaces

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.26 · Dockboards

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other beer and ale merchant wholesalers employers in North Carolina

Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.