Benton Electric Inc: OSHA inspections and violations

Corvallis, Oregon · Electrical Contractors and Other Wiring Installation Contractors · NAICS 238210

27inspections
43citation items
$4,230current penalties
Jan 29, 2019last inspection

OSHA has inspected Benton Electric Inc 27 times in Oregon since 1985.

The latest one began on Jan 29, 2019 as a planned inspection, in Albany.

Those inspections ended with 43 citation items: 17 serious and 26 other-than-serious.

Penalties were first proposed at $4,230 and still stand at $4,230.

comes up most often in these citations: 4 items under 7010.7650.

How that compares: the median penalty per cited inspection for construction employers since 2015 is $3,080, and Benton Electric Inc averages $1,260 (1 cited inspection).

Benton Electric Inc: OSHA citation items per year, 1985 to 2019
Citation items per year, by inspection date.

Oregon · latest 90 days of OSHA records

386employers cited

7 of them in the same industry

Get notified the morning OSHA posts each new citation in Oregon: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Oregon

Checking a subcontractor, a client or your own company? Watch Benton Electric Inc and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343751517 OPENED JAN 29, 2019Closed

Planned · Complete · Safety · 25 employees at the site · Closed May 6, 2019

3705 Se Columbus St, Albany, OR 97322 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 341020170 OPENED SEP 28, 2015Closed

Planned · Complete · Safety · 18 employees at the site · Closed Mar 17, 2016

34037 Excor Rd, Albany, OR 97321 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$100$100Oct 29, 2015Final
Citation 1, item 2
29 CFR 1910.176(b) · Material storage and aisles
Serious$200$200Oct 29, 2015Final
Citation 1, item 3
29 CFR OAR 437-002-0026(5)(E)-1
Serious$120$120Oct 29, 2015Final
Citation 1, item 4
29 CFR OAR 437-002-0221(13)(A)-2
Serious$120$120Oct 29, 2015Final
Citation 1, item 5
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$120$120Oct 29, 2015Final
Citation 1, item 6
29 CFR 1910.215(a)(1) · Grinders and abrasive wheels
Serious$120$120Oct 29, 2015Final
Citation 1, item 7
29 CFR 1910.23(d)(1) · Guarding floor and wall openings and holes
Serious$120$120Oct 29, 2015Final
Citation 1, item 8
29 CFR OAR 437-002-0022(3)(F)
Serious$120$120Oct 29, 2015Final
Citation 1, item 9
29 CFR OAR 437-001-0765(1)
Serious$120$120Oct 29, 2015Final
Citation 1, item 10
29 CFR 1910.178(l)(1)(i) · Forklifts and other powered industrial trucks
Serious$120$120Oct 29, 2015Final
Citation 2, item 11
29 CFR OAR 437-002-0187(2)-2
Other-than-serious$0$0Oct 29, 2015Final
Citation 2, item 12
29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements
Other-than-serious$0$0Oct 29, 2015Final
Citation 2, item 13
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Oct 29, 2015Final
Citation 2, item 14
29 CFR OAR 437-002-0187(4)-2
Other-than-serious$0$0Oct 29, 2015Final

Inspection 312710296 OPENED OCT 5, 2008Closed

Planned · Complete · Safety · 3 employees at the site · Closed Mar 6, 2009

400 Nw Hickory Ave, Albany, OR 97321 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Nov 24, 2008Closed
Citation 1, item 2
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Other-than-serious$0$0Nov 24, 2008Closed

Inspection 306966243 OPENED SEP 18, 2003Closed

Unprogrammed other · Partial · Safety · 4 employees at the site · Closed Feb 6, 2004

630 W 7th, Corvallis, OR 97330 · Electrical Contractors and Other Wiring Installation Contractors · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.405(b)(1) · Job-site wiring
Other-than-serious$0$0Oct 13, 2003Closed

Inspection 304749401 OPENED JAN 16, 2002Closed

Accident · Partial · Safety · 38 employees at the site · Closed Jul 30, 2002

500 N 5th, Lebanon, OR 97355 · OSHA's record · Phone and website on Google Maps

Incident on Jan 4, 2002: Employee fractures ribs in fall with ladder

On January 4, 2002, Employee #1, of Benton Electric, Inc., was using a 10 ft ste pladder to drill a hole in the wood framing of a building under construction in preparation for running conduit. As he was working, he shifted his weight to giv e himself better leverage. To do this, Employee #1 placed his left foot on a woo den fire break in the wall that unexpectedly gave way. He started to lose his ba lance and slid his right foot over to a point that the ladder overturned away fr om the wall. Employee #1 fell 8 ft onto a concrete floor. He sustained three fra ctured ribs and was transported to a local hospital, where he was admitted for t reatment.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$500$500Mar 20, 2002Closed
Citation 1, item 2
29 CFR 7010052
Other-than-serious$250$250Mar 20, 2002Closed

Inspection 304814650 OPENED DEC 11, 2001Closed

Planned · Complete · Safety · 2 employees at the site · Closed Jun 26, 2002

8800 Hoffman Rd, Monmouth, OR 97361 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$500$500Feb 8, 2002Closed

Inspection 304229552 OPENED SEP 4, 2001Closed

Planned · Partial · Safety · 27 employees at the site · Closed Sep 4, 2001

3600 Samaritan Drive, Corvallis, OR 97330 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 304070378 OPENED JUN 19, 2001Closed

Planned · Partial · Safety · 50 employees at the site · Closed Jun 19, 2001

1046 Sw 6th Ave, Albany, OR 97321 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

19 older inspections

Inspection 303172910 OPENED MAR 8, 2000Closed

Planned · Complete · Safety · 35 employees at the site · Closed Mar 10, 2000

535 South 19th Street, Philomath, OR 97370 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303169528 OPENED DEC 15, 1999Closed

Planned · Complete · Safety · 2 employees at the site · Closed Dec 15, 1999

3517 Nw Samaritan, Corvallis, OR 97330 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 303130587 OPENED DEC 1, 1999Closed

Planned · Complete · Safety · 3 employees at the site · Closed Nov 20, 2000

33800 Se Harder St, Scappoose, OR 97056 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(f)(6) · Ground-fault protection on job sites
Other-than-serious$0$0Jan 31, 2000Closed
Citation 1, item 2 Other-than-serious$0$0Jan 31, 2000Closed

Inspection 302595459 OPENED JUN 16, 1999Closed

Planned · Complete · Safety · 40 employees at the site · Closed Dec 16, 1999

16 Miles N Of Redmond On Hwy 97, Redmond, OR 97756 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$100$100Jul 8, 1999Closed

Inspection 302593876 OPENED MAY 3, 1999Closed

Unprogrammed other · Complete · Safety · 45 employees at the site · Closed May 3, 1999

1460 Ne 27th Street, Bend, OR 97701 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 302292982 OPENED NOV 24, 1998Closed

Unprogrammed other · Complete · Safety · 40 employees at the site · Closed Nov 24, 1998

4700 Holly Hock Circle, Corvallis, OR 97333 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126684471 OPENED MAY 28, 1998Closed

Unprogrammed other · Complete · Safety · 20 employees at the site · Closed Oct 31, 2002

3600 Samaritan Drive Ancillary Building, Corvallis, OR 97330 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Other-than-serious$0$0Jul 14, 1998Closed

Inspection 126687235 OPENED NOV 4, 1997Closed

Planned · Complete · Safety · 30 employees at the site · Closed Feb 27, 2003

9th & Grant Sw Corner, Corvallis, OR 97330 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.652(a)(1) · Trench protection
Serious$375$375Dec 26, 1997Closed
Citation 1, item 2
29 CFR 1926.651(k)(1) · Excavations
Serious$825$825Dec 26, 1997Closed
Citation 1, item 3
29 CFR 1926.651(c)(2) · Excavations
Serious$100$100Dec 26, 1997Closed

Inspection 126680511 OPENED SEP 17, 1996Closed

Planned · Complete · Safety · 29 employees at the site · Closed Jun 27, 1997

Dpi Millersburg, Albany, OR 97321 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.602(a)(9)(i) · Earthmovers and forklifts in construction
Other-than-serious$0$0Oct 7, 1996Closed

Inspection 124684408 OPENED MAR 11, 1996Closed

Planned · Complete · Safety · 1 employee at the site · Closed Mar 11, 1996

Tangent Industrial Park, Tangent, OR 97389 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 126705086 OPENED DEC 27, 1995Closed

Planned · Complete · Safety · 3 employees at the site · Closed Feb 28, 1996

333 Broadalbin St, Albany, OR 97321 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.403(i)(2)(i) · Electrical equipment on job sites
Serious$180$180Jan 30, 1996Closed
Citation 2, item 2
29 CFR 1926.404(b)(1)(iiic) · Ground-fault protection on job sites
Other-than-serious$0$0Jan 30, 1996Closed
Citation 2, item 3 Other-than-serious$0$0Jan 30, 1996Closed

Inspection 126247956 OPENED NOV 6, 1995Closed

Planned · Complete · Safety · 3 employees at the site · Closed Feb 28, 1996

333 Broadalbin St, Albany, OR 97321 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.250(a)(3) · General requirements for storage
Other-than-serious$0$0Dec 13, 1995Closed

Inspection 108258906 OPENED APR 15, 1991Closed

Follow-up · Complete · Safety · 25 employees at the site · Closed Apr 15, 1991

500 N 5th, Lebanon, OR 97355 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 108258187 OPENED DEC 10, 1990Closed

Planned · Complete · Safety · 2 employees at the site · Closed Apr 23, 1991

500 N 5th, Lebanon, OR 97355 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.404(b)(1)(iii) · Ground-fault protection on job sites
Other-than-serious$0$0Jan 10, 1991Closed

Inspection 105256499 OPENED AUG 16, 1989Closed

Planned · Complete · Safety · 3 employees at the site · Closed Aug 18, 1989

400 Madrona St S, Salem, OR 97302 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 105309223 OPENED JUN 6, 1989Closed

Planned · Complete · Safety · 3 employees at the site · Closed Nov 17, 1989

Intersection Of Silverton Rd & Hawthorne Ne, Salem, OR 97305 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.100(a) · Hard hats in construction
Serious$75$75Jun 21, 1989Closed
Citation 2, item 2
29 CFR 1926.550(a)(2) · [Reserved]
Other-than-serious$0$0Jun 21, 1989Closed
Citation 2, item 3
29 CFR 1926.152(a)(1) · Flammable liquids
Other-than-serious$0$0Jun 21, 1989Closed
Citation 2, item 4
29 CFR 1926.59(e)(1) · Hazard communication
Other-than-serious$0$0Jun 21, 1989Closed
Citation 2, item 5
29 CFR 1926.59(f)(5) · Hazard communication
Other-than-serious$0$0Jun 21, 1989Closed
Citation 2, item 6
29 CFR 1926.59(g)(8) · Hazard communication
Other-than-serious$0$0Jun 21, 1989Closed
Citation 2, item 7
29 CFR 1926.59(h) · Hazard communication
Other-than-serious$0$0Jun 21, 1989Closed

Inspection 105300198 OPENED JUL 13, 1987Closed

Planned · Complete · Safety · 1 employee at the site · Closed Nov 23, 1987

I 105 Off Ramp And Country Club Rd, Eugene, OR 97401 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7831846
Other-than-serious$0$0Aug 5, 1987Closed

Inspection 3116027 OPENED JUL 8, 1986Closed

Planned · Complete · Safety · 2 employees at the site · Closed Sep 5, 1986

Hwy 99 W & Mcdaniel Ln, Mcminnville, OR 97128 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 7833106
Serious$65$65Jul 30, 1986Closed

Inspection 3108370 OPENED JUL 25, 1985Closed

Planned · Complete · Safety · 1 employee at the site · Closed Oct 11, 1985

Evanite Office Crystal Lake Dr, Corvallis, OR 97330 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1 Other-than-serious$0$0Aug 13, 1985Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.176 · Material storage and aisles

29 CFR 1910.176(b)

(b) Secure storage. Storage of material shall not create a hazard. Bags, containers, bundles, etc., stored in tiers shall be stacked, blocked, interlocked and limited in height so that they are stable and secure against sliding or collapse.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.178(l)(1)(i)

(l) Operator training. (1) Safe operation. (i) The employer shall ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l).

29 CFR 1910.178(l)(4)(iii)

(iii) An evaluation of each powered industrial truck operator's performance shall be conducted at least once every three years.

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.22 · General requirements

29 CFR 1910.23 · Guarding floor and wall openings and holes

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1926.100 · Hard hats in construction

29 CFR 1926.152 · Flammable liquids

29 CFR 1926.250 · General requirements for storage

29 CFR 1926.403 · Electrical equipment on job sites

29 CFR 1926.404 · Ground-fault protection on job sites

29 CFR 1926.405 · Job-site wiring

29 CFR 1926.550 · [Reserved]

29 CFR 1926.59 · Hazard communication

29 CFR 1926.602 · Earthmovers and forklifts in construction

29 CFR 1926.651 · Excavations

29 CFR 1926.652 · Trench protection

29 CFR 7010.7650

29 CFR 7030.5030

29 CFR 7831.6640

Other electrical contractors and other wiring installation contractors employers in Oregon

Alert subscribers get notified of each newly cited employer in Oregon the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.