OSHA SearchOSHA records by employer

Berrien Built Cabinets, Inc.: OSHA inspections and violations

Nashville, Georgia · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

1inspections
18citation items
$5,683current penalties
Dec 18, 2018last inspection

Berrien Built Cabinets, Inc. has one OSHA inspection on record in Georgia.

OSHA opened it on Dec 18, 2018 after a complaint, in Nashville.

From that inspection OSHA issued 18 citation items: 16 serious and 2 other-than-serious.

OSHA proposed $11,366 in penalties. After settlements and reviews the total is $5,683, down 50%.

Most often, OSHA cited 1910.107, spray painting and finishing (6 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Berrien Built Cabinets, Inc. averages $5,683 over 1 cited inspection in that time.

Berrien Built Cabinets, Inc.: OSHA citation items per year, 2018 to 2018
Citation items per year, by inspection date.

Georgia · latest 90 days of OSHA records

145employers cited

Get notified the morning OSHA posts each new citation in Georgia: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Georgia

Checking a subcontractor, a client or your own company? Watch Berrien Built Cabinets, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 343678363 OPENED DEC 18, 2018Closed

Complaint · Partial · Safety · 6 employees at the site · Closed Jun 12, 2020

519 South Bartow Street, Nashville, GA 31639 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$2,273$1,136May 24, 2019Final
Citation 1, item 1b
29 CFR 1910.107(b)(9) · Spray painting and finishing
Serious$0$0May 24, 2019Final
Citation 1, item 1c
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0May 24, 2019Final
Citation 1, item 1d
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0May 24, 2019Final
Citation 1, item 2a
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$2,273$1,136May 24, 2019Final
Citation 1, item 2b
29 CFR 1910.107(c)(4) · Spray painting and finishing
Serious$0$0May 24, 2019Final
Citation 1, item 2c
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$0$0May 24, 2019Final
Citation 1, item 2d
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0May 24, 2019Final
Citation 1, item 3
29 CFR 1910.157(g)(1) · Portable fire extinguishers
Serious$2,273$1,136May 24, 2019Final
Citation 1, item 4a
29 CFR 1910.213(a)(9) · Woodworking machinery
Serious$2,842$1,421May 24, 2019Final
Citation 1, item 4b
29 CFR 1910.213(p)(4) · Woodworking machinery
Serious$0$0May 24, 2019Final
Citation 1, item 4c
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0May 24, 2019Final
Citation 1, item 4d
29 CFR 1910.219(e)(3)(i) · Belts, pulleys and power-transmission parts
Serious$0$0May 24, 2019Final
Citation 1, item 5a
29 CFR 1910.1200(e)(1) · Hazard communication
Serious$1,705$852May 24, 2019Final
Citation 1, item 5b
29 CFR 1910.1200(g)(1) · Hazard communication
Serious$0$0May 24, 2019Final
Citation 1, item 5c
29 CFR 1910.1200(h)(1) · Hazard communication
Serious$0$0May 24, 2019Final
Citation 2, item 1
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0May 24, 2019Final
Citation 2, item 2
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0May 24, 2019Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(9)

(9) Cleaning. Spray booths shall be so installed that all portions are readily accessible for cleaning. A clear space of not less than 3 feet on all sides shall be kept free from storage or combustible construction.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.134 · Respiratory protection

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other wood kitchen cabinet and countertop manufacturing employers in Georgia

Alert subscribers get notified of each newly cited employer in Georgia the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.