OSHA SearchOSHA records by employer

Betenbender MFG., Inc.: OSHA inspections and violations

Coggon, Iowa · Machine Tool Manufacturing · NAICS 333517

6inspections
35citation items
$11,631current penalties
Mar 27, 2024last inspection

Since 1980, OSHA inspectors have visited Betenbender MFG., Inc. in Iowa 6 times.

The most recent inspection opened on Mar 27, 2024 as a planned inspection, in Coggon.

In all, OSHA issued 35 citation items: 24 serious and 11 other-than-serious.

The proposed penalties came to $20,902; today they stand at $11,631, 44% less.

The rule cited most here is 1910.303 (electrical equipment, general requirements), 5 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Betenbender MFG., Inc. averages $9,271 across 1 cited inspection.

Betenbender MFG., Inc.: OSHA citation items per year, 1980 to 2024
Citation items per year, by inspection date.

Iowa · latest 90 days of OSHA records

68employers cited

Get notified the morning OSHA posts each new citation in Iowa: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Iowa

Checking a subcontractor, a client or your own company? Watch Betenbender MFG., Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347375842 OPENED MAR 27, 2024Closed

Planned · Partial · Safety · 21 employees at the site · Closed Dec 2, 2024

5806 Quality Ridge Road Po Box 48, Coggon, IA 52218 · Machine Tool Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.101(b) · Compressed gases (general requirements)
Serious$2,679$1,340Jul 25, 2024Final
Citation 1, item 2
29 CFR 1910.147(c)(1) · Lockout/tagout
Serious$3,349$1,674Jul 25, 2024Final
Citation 1, item 3a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$4,688$2,344Jul 25, 2024Final
Citation 1, item 3b
29 CFR 1910.212(a)(3)(iv)(d) · Machine guarding
Serious$0$0Jul 25, 2024Final
Citation 1, item 4a
29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts
Serious$3,349$1,674Jul 25, 2024Final
Citation 1, item 4b
29 CFR 1910.219(c)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Jul 25, 2024Final
Citation 1, item 4c
29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts
Serious$0$0Jul 25, 2024Final
Citation 1, item 4d
29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts
Serious$0$0Jul 25, 2024Final
Citation 1, item 4e
29 CFR 1910.219(f)(3) · Belts, pulleys and power-transmission parts
Serious$0$0Jul 25, 2024Final
Citation 1, item 5a
29 CFR 1910.303(b)(2) · Electrical equipment, general requirements
Serious$3,349$1,674Jul 25, 2024Final
Citation 1, item 5b
29 CFR 1910.303(g)(1) · Electrical equipment, general requirements
Serious$0$0Jul 25, 2024Final
Citation 1, item 5c
29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements
Serious$0$0Jul 25, 2024Final
Citation 1, item 5d
29 CFR 1910.305(b)(1)(i) · Electrical wiring methods
Serious$0$0Jul 25, 2024Final
Citation 1, item 5e
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$0$0Jul 25, 2024Final
Citation 2, item 1
29 CFR 1904.29(a) · Injury and illness log
Other-than-serious$376$188Jul 25, 2024Final
Citation 2, item 2
29 CFR 1910.132(d)(2) · Personal protective equipment, general requirements
Other-than-serious$376$188Jul 25, 2024Final
Citation 2, item 3
29 CFR 1910.303(f)(2) · Electrical equipment, general requirements
Other-than-serious$376$188Jul 25, 2024Final

Inspection 115067985 OPENED SEP 13, 1994Closed

Planned · Complete · Health · 24 employees at the site · Closed Nov 28, 1994

5806 Quality Ridge Road, Coggon, IA 52218 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Other-than-serious$0$0Oct 19, 1994Closed

Inspection 115063471 OPENED MAY 5, 1993Closed

Complaint · Partial · Health · 15 employees at the site · Closed Jan 5, 1996

5806 Quality Ridge Road, Coggon, IA 52218 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting
Serious$1,000$1,000Jul 22, 1993Closed

Inspection 104256391 OPENED AUG 13, 1990Closed

Follow-up · Partial · Safety · 16 employees at the site · Closed Aug 13, 1990

5806 Quality Ridge Road, Coggon, IA 52218 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Inspection 104250766 OPENED APR 19, 1990Closed

Planned · Complete · Safety · 16 employees at the site · Closed Aug 13, 1990

5806 Quality Ridge Road, Coggon, IA 52218 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.106(e)(6)(ii) · Flammable liquids
Serious$120$120Jun 21, 1990Closed
Citation 1, item 2
29 CFR 1910.179(g)(1)(v) · Overhead and gantry cranes
Serious$120$120Jun 21, 1990Closed
Citation 1, item 3
29 CFR 1910.179(j)(2)(iii) · Overhead and gantry cranes
Serious$120$120Jun 21, 1990Closed
Citation 1, item 4
29 CFR 1910.179(l)(1) · Overhead and gantry cranes
Serious$160$160Jun 21, 1990Closed
Citation 1, item 5
29 CFR 1910.179(m)(1) · Overhead and gantry cranes
Serious$120$120Jun 21, 1990Closed
Citation 1, item 6
29 CFR 1910.215(a)(4) · Grinders and abrasive wheels
Serious$160$160Jun 21, 1990Closed
Citation 1, item 7
29 CFR 1910.215(b)(9) · Grinders and abrasive wheels
Serious$160$160Jun 21, 1990Closed
Citation 1, item 8
29 CFR 1910.303(f) · Electrical equipment, general requirements
Serious$120$120Jun 21, 1990Closed
Citation 1, item 9
29 CFR 1910.305(b)(2) · Electrical wiring methods
Serious$80$80Jun 21, 1990Closed
Citation 2, item 1
29 CFR 30001
Other-than-serious$100$100Jun 21, 1990Closed
Citation 2, item 2
29 CFR 40002 1
Other-than-serious$100$100Jun 21, 1990Closed
Citation 2, item 3
29 CFR 1200003 1
Other-than-serious$0$0Jun 21, 1990Closed
Citation 2, item 4
29 CFR 1200006
Other-than-serious$0$0Jun 21, 1990Closed
Citation 2, item 5
29 CFR 1910.22(d)(1) · General requirements
Other-than-serious$0$0Jun 21, 1990Closed
Citation 2, item 6
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Jun 21, 1990Closed
Citation 2, item 7
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Jun 21, 1990Closed

Inspection 18788349 OPENED JUN 19, 1980Closed

Planned · No inspection · Safety · Closed Feb 12, 1988

Coggon, IA 00000 · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.29 · Injury and illness log

29 CFR 1904.29(a)

(a) Basic requirement. You must use OSHA 300, 300-A, and 301 forms, or equivalent forms, for recordable injuries and illnesses. The OSHA 300 form is called the Log of Work-Related Injuries and Illnesses, the 300-A is the Summary of Work-Related Injuries and Illnesses, and the OSHA 301 form is called the Injury and Illness Incident Report.

29 CFR 1910.101 · Compressed gases (general requirements)

29 CFR 1910.101(b)

(b) Compressed gases. The in-plant handling, storage, and utilization of all compressed gases in cylinders, portable tanks, rail tankcars, or motor vehicle cargo tanks shall be in accordance with Compressed Gas Association Pamphlet P-1-1965, which is incorporated by reference as specified in § 1910.6.

29 CFR 1910.106 · Flammable liquids

29 CFR 1910.106(e)(6)(ii)

(ii) Grounding. Category 1 or 2 flammable liquids, or Category 3 flammable liquids with a flashpoint below 100 °F (37.8 °C), shall not be dispensed into containers unless the nozzle and container are electrically interconnected. Where the metallic floorplate on which the container stands while filling is electrically connected to the fill stem or where the fill stem is bonded to the container during filling operations by means of a bond wire, the provisions of this section shall be deemed to have been complied with.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.132 · Personal protective equipment, general requirements

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.179 · Overhead and gantry cranes

29 CFR 1910.212 · Machine guarding

29 CFR 1910.215 · Grinders and abrasive wheels

29 CFR 1910.219 · Belts, pulleys and power-transmission parts

29 CFR 1910.22 · General requirements

29 CFR 1910.253 · Gas welding and cutting

29 CFR 1910.303 · Electrical equipment, general requirements

29 CFR 1910.305 · Electrical wiring methods

Other machine tool manufacturing employers in Iowa

Alert subscribers get notified of each newly cited employer in Iowa the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.