Beto's Muffler: OSHA inspections and violations

El Paso, Texas · Automotive Exhaust System Repair · NAICS 811112

1inspections
3citation items
$0current penalties
Dec 23, 2015last inspection

OSHA has inspected Beto's Muffler once in Texas.

The inspection began on Dec 23, 2015 after a complaint, in El Paso.

That inspection ended with 3 citation items: 3 serious.

None of the citations carried a penalty.

How that compares: the median penalty per cited inspection for repair and personal services employers since 2015 is $1,200, and Beto's Muffler averages $0 (1 cited inspection).

Beto's Muffler: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Texas · latest 90 days of OSHA records

394employers cited

Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Texas

Checking a subcontractor, a client or your own company? Watch Beto's Muffler and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341145720 OPENED DEC 23, 2015Closed

Complaint · Partial · Safety · 2 employees at the site · Closed May 18, 2016

6614 Alameda Ave., El Paso, TX 79905 · Automotive Exhaust System Repair · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
OSH Act Section 5(a)(1) · General Duty Clause
Serious$0$0Feb 29, 2016Final
Citation 1, item 2
29 CFR 1910.305(b)(2)(i) · Electrical wiring methods
Serious$0$0Feb 29, 2016Final
Citation 1, item 3
29 CFR 1910.334(a)(2)(i) · Using electrical equipment
Serious$0$0Feb 29, 2016Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.305(b)(2)(i)

(2) Covers and canopies. (i) All pull boxes, junction boxes, and fittings shall be provided with covers identified for the purpose. If metal covers are used, they shall be grounded. In completed installations, each outlet box shall have a cover, faceplate, or fixture canopy. Covers of outlet boxes having holes through which flexible cord pendants pass shall be provided with bushings designed for the purpose or shall have smooth, well-rounded surfaces on which the cords may bear.

29 CFR 1910.334 · Using electrical equipment

29 CFR 1910.334(a)(2)(i)

(2) Visual inspection. (i) Portable cord- and plug-connected equipment and flexible cord sets (extension cords) shall be visually inspected before use on any shift for external defects (such as loose parts, deformed and missing pins, or damage to outer jacket or insulation) and for evidence of possible internal damage (such as pinched or crushed outer jacket). Cord- and plug-connected equipment and flexible cord sets (extension cords) which remain connected once they are put in place and are not exposed to damage need not be visually inspected until they are relocated.

OSH Act Section 5 · General Duty Clause

OSH Act Section 5(a)(1)

Each employer shall furnish to each of his employees employment and a place of employment which are free from recognized hazards that are causing or are likely to cause death or serious physical harm to his employees.

Other automotive exhaust system repair employers in Texas

Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.