OSHA SearchOSHA records by employer

Blair Technology Group LLC: OSHA inspections and violations

Covington, Kentucky · Electronics and Appliance Stores · NAICS 443120

1inspections
11citation items
$1,100current penalties
Jan 16, 2015last inspection

Blair Technology Group LLC has one OSHA inspection on record in Kentucky.

OSHA opened it on Jan 16, 2015 after a complaint, in Covington.

From that inspection OSHA issued 11 citation items: 6 serious and 5 other-than-serious.

OSHA proposed $2,750 in penalties. After settlements and reviews the total is $1,100, down 60%.

Most often, OSHA cited 1910.107, spray painting and finishing (6 items).

For context, across all retail employers the median penalty per cited inspection since 2015 is $1,750. Blair Technology Group LLC averages $1,100 over 1 cited inspection in that time.

Blair Technology Group LLC: OSHA citation items per year, 2015 to 2015
Citation items per year, by inspection date.

Kentucky · latest 90 days of OSHA records

181employers cited

Get notified the morning OSHA posts each new citation in Kentucky: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in Kentucky

Checking a subcontractor, a client or your own company? Watch Blair Technology Group LLC and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 317642775 OPENED JAN 16, 2015Closed

Complaint · Partial · Health · 53 employees at the site · Closed Jul 29, 2015

4314 Boron Drive, Covington, KY 41011 · Electronics and Appliance Stores · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(c)(3) · Spray painting and finishing
Serious$2,750$1,100Jun 24, 2015Closed
Citation 1, item 1b
29 CFR 1910.107(c)(6) · Spray painting and finishing
Serious$0$0Jun 24, 2015Closed
Citation 1, item 1c
29 CFR 1910.107(d)(2) · Spray painting and finishing
Serious$0$0Jun 24, 2015Closed
Citation 1, item 1d
29 CFR 1910.107(f)(4) · Spray painting and finishing
Serious$0$0Jun 24, 2015Closed
Citation 1, item 1e
29 CFR 1910.107(g)(2) · Spray painting and finishing
Serious$0$0Jun 24, 2015Closed
Citation 1, item 1f
29 CFR 1910.107(g)(7) · Spray painting and finishing
Serious$0$0Jun 24, 2015Closed
Citation 2, item 1 Other-than-serious$0$0Jun 24, 2015Closed
Citation 2, item 2
29 CFR 1910.134(c)(1) · Respiratory protection
Other-than-serious$0$0Jun 24, 2015Closed
Citation 2, item 3
29 CFR 1910.134(e)(1) · Respiratory protection
Other-than-serious$0$0Jun 24, 2015Closed
Citation 2, item 4
29 CFR 1910.134(f)(1) · Respiratory protection
Other-than-serious$0$0Jun 24, 2015Closed
Citation 2, item 5
29 CFR 1910.134(k)(1)(i) · Respiratory protection
Other-than-serious$0$0Jun 24, 2015Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(c)(3)

(3) Hot surfaces. Space-heating appliances, steampipes, or hot surfaces shall not be located in a spraying area where deposits of combustible residues may readily accumulate.

29 CFR 1910.107(c)(6)

(6) Wiring type approved. Electrical wiring and equipment not subject to deposits of combustible residues but located in a spraying area as herein defined shall be of explosion-proof type approved for Class I, group D locations and shall otherwise conform to the provisions of subpart S of this part, for Class I, Division 1, Hazardous Locations. Electrical wiring, motors, and other equipment outside of but within twenty (20) feet of any spraying area, and not separated therefrom by partitions, shall not produce sparks under normal operating conditions and shall otherwise conform to the provisions of subpart S of this part for Class I, Division 2 Hazardous Locations.

29 CFR 1910.107(d)(2)

(2) General. All spraying areas shall be provided with mechanical ventilation adequate to remove flammable vapors, mists, or powders to a safe location and to confine and control combustible residues so that life is not endangered. Mechanical ventilation shall be kept in operation at all times while spraying operations are being conducted and for a sufficient time thereafter to allow vapors from drying coated articles and drying finishing material residue to be exhausted.

29 CFR 1910.134 · Respiratory protection

29 CFR 2031.10

Other electronics and appliance stores employers in Kentucky

Alert subscribers get notified of each newly cited employer in Kentucky the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.