OSHA SearchOSHA records by employer

Blattner Energy: OSHA inspections and violations

Iraan, Texas · Wind Electric Power Generation · NAICS 221115

6inspections
6citation items
$65,110current penalties
Aug 31, 2026last inspection

OSHA has inspected Blattner Energy 6 times in Texas since 2015.

The latest one began on Aug 31, 2026 as part of a related case, in Silver; the case is still open.

Those inspections ended with 6 citation items: 2 serious and 4 other-than-serious.

Penalties were first proposed at $72,370 and now stand at $65,110, 10% lower after settlements or reviews.

Fall protection in construction comes up most often in these citations: 2 items under 1926.501.

How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Blattner Energy averages $16,278 (4 cited inspections).

It reported 3 severe injuries to OSHA since 2015.

Blattner Energy: OSHA citation items per year, 2015 to 2026
Citation items per year, by inspection date.

Want to know if OSHA cites Blattner Energy again? Add it to a watchlist and we will email you the morning the citation shows up.

Watch this company

Inspection history

Inspection 349191742 OPENED AUG 31, 2026Open

Unprogrammed related · Partial · Health · 270 employees at the site · Open

Goat Mountain Wind Farm, Silver, TX 76945 · Wind Electric Power Generation · OSHA's record · Phone and website on Google Maps

No citations from this inspection so far.

Inspection 348286451 OPENED JUN 3, 2025Closed

Referral · Partial · Safety · 10 employees at the site · Closed Jun 26, 2026

600 County Road 310, Iraan, TX 79744 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$13,240$13,240Sep 30, 2025Final

Inspection 348210915 OPENED APR 29, 2025Closed

Referral · Partial · Safety · 10 employees at the site · Closed Jun 26, 2026

600 County Road 310, Iraan, TX 79744 · Power and Communication Line and Related Structures Construction · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.501(b)(4)(ii) · Fall protection in construction
Other-than-serious$11,350$11,350Sep 30, 2025Final
Citation 1, item 2
29 CFR 1926.503(a)(2) · Fall protection training in construction
Other-than-serious$11,350$11,350Sep 30, 2025Final

Inspection 347923674 OPENED DEC 9, 2024Open

Unprogrammed related · Partial · Safety · 10 employees at the site · Open

6969 Shaw Road, Temple, TX 76501 · Solar Electric Power Generation · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.147(f)(3)(i) · Lockout/tagout
Serious$11,585$11,585Jun 4, 2025Final
Citation 1, item 2
29 CFR 1910.335(a)(1)(i) · Safeguards for personnel protection
Serious$11,585$11,585Jun 4, 2025Final

Inspection 343472130 OPENED SEP 19, 2018Closed

Referral · Partial · Safety · 3,000 employees at the site · Closed Apr 1, 2019

1440 C.r. 431, Eldorado, TX 76936 · Other Communication and Energy Wire Manufacturing · OSHA's record · Phone and website on Google Maps

Incident on Aug 28, 2018: Employee amputates toes when caught in nip point between rot

At 9:45 a.m. on August 28, 2018, an employee was installing the OVP box when he stepped into a pinch point between the rotating shaft and the main bearing house. The employee was amputated several toes and was hospitalized.

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1926.307(c)(2)(i) · Mechanical power-transmission apparatus
Other-than-serious$13,260$6,000Jan 25, 2019Final

Inspection 341056778 OPENED NOV 13, 2015Closed

Referral · Partial · Safety · 2,050 employees at the site · Closed Nov 19, 2015

5138 S Fm 649, Mirando City, TX 78369 · Wind Electric Power Generation · OSHA's record · Phone and website on Google Maps

No citations from this inspection.

Severe injury reports

Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 3 reports on file.

Jun 2, 2025, Iraan: Hospitalization · fractures · arm(s) unspecified

An employee was painting in the middle section of a tower when she fell 70 feet through the hatch. The employee was hospitalized with arm fractures.

Aug 28, 2018, Eldorado: Hospitalization, amputation · amputations · toes(s), toenail(s)

An employee was installing an electrical box when the employee's foot was caught between a free spinning turbine and the counterweight and main bearing of a piece of machinery, causing the amputation of five toes.

Nov 9, 2015, Mirando City: Hospitalization · fractures and other injuries, n.e.c. · neck and back

An employee was handling a windmill edge protector as it was being lifted by a crane. The edge protector fell on top of him as he stood underneath it, fracturing his neck and compressing his spine vertebrae.

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(f)(3)(i)

(3) Group lockout or tagout. (i) When servicing and/or maintenance is performed by a crew, craft, department or other group, they shall utilize a procedure which affords the employees a level of protection equivalent to that provided by the implementation of a personal lockout or tagout device.

29 CFR 1910.335 · Safeguards for personnel protection

29 CFR 1910.335(a)(1)(i)

(a) Use of protective equipment—(1) Personal protective equipment. (i) Employees working in areas where there are potential electrical hazards shall be provided with, and shall use, electrical protective equipment that is appropriate for the specific parts of the body to be protected and for the work to be performed.

29 CFR 1926.307 · Mechanical power-transmission apparatus

29 CFR 1926.307(c)(2)(i)

(2) Guarding horizontal shafting. (i) All exposed parts of horizontal shafting 7 feet (2.128 m) or less from floor or working platform, excepting runways used exclusively for oiling, or running adjustments, shall be protected by a stationary casing enclosing shafting completely or by a trough enclosing sides and top or sides and bottom of shafting as location requires.

29 CFR 1926.501 · Fall protection in construction

29 CFR 1926.503 · Fall protection training in construction

Other wind electric power generation employers in Texas

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.