Inspection 349123232 OPENED AUG 19, 2026Open
15818 West State Highway 22, Frost, TX 76641 · Wind Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
Raymondville, Texas · Wind Electric Power Generation · NAICS 221115
OSHA has inspected Rwe Renewables Americas, LLC 2 times in Texas since 2021.
The latest one began on Aug 19, 2026 as part of a related case, in Frost; the case is still open.
Those inspections ended with 1 citation item: 1 other-than-serious.
Penalties were first proposed at $9,753 and still stand at $9,753.
How that compares: the median penalty per cited inspection for utility employers since 2015 is $0, and Rwe Renewables Americas, LLC averages $9,753 (1 cited inspection).
It reported 1 severe injury to OSHA since 2015.
Texas · latest 90 days of OSHA records
399employers cited
Get notified the morning OSHA posts each new citation in Texas: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in Texas
Checking a subcontractor, a client or your own company? Watch Rwe Renewables Americas, LLC and get notified the morning OSHA posts a new citation for it.
Watch this company15818 West State Highway 22, Frost, TX 76641 · Wind Electric Power Generation · OSHA's record · Phone and website on Google Maps
No citations from this inspection so far.
12550 Pennington Rd, Raymondville, TX 78580 · Wind Electric Power Generation · OSHA's record · Phone and website on Google Maps
Incident on Dec 7, 2021: Employee breaks wrist, tears skin when caught in heavy cable
At 9:45 a.m. on December 7, 2021, an employee was standing on a on a 360-degree platform dropping a 330-foot long, 10-mm cable from a nacelle during installation. The employee was in the process of dropping the spooled cable down the tower approximately 300 feet while readying a wind turbine blade for repair. The employee was required to drop a total of four cables, each weighing 90 pounds. As the employee was lowering a cable it became tangled. As the employee attempted to untangle the cable, his hand and wrist got caught in the cable. The employee broke his wrist and tore the skin around his wrist and hand, requiring hospitalization.
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1904.39(a)(2) · Reporting deaths and severe injuries |
Other-than-serious | $9,753 | $9,753 | Dec 28, 2021 | Final |
Employers must report any work-related amputation, in-patient hospitalization or loss of an eye to OSHA within 24 hours. 1 report on file.
Dec 7, 2021, Raymondville: Hospitalization · fractures · wrist(s)
An employee was in the process of dropping a 10-millimeter wire cable spooled up in a wind turbine's nacelle and lowering it approximately 300 feet down the turbine's tower. There are four total cables to be dropped down, each weighing 90 pounds. As the technician was lowering one of the cables, it became tangled. Trying to untangle the cable, the technician's hand and wrist got caught in the…
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1904.39(a)(2)
(2) Within twenty-four (24) hours after the in-patient hospitalization of one or more employees or an employee's amputation or an employee's loss of an eye, as a result of a work-related incident, you must report the in-patient hospitalization, amputation, or loss of an eye to OSHA.
Alert subscribers get notified of each newly cited employer in Texas the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.