Blue Ridge Cabinetry, Inc.: OSHA inspections and violations

Forest City, North Carolina · Wood Kitchen Cabinet and Countertop Manufacturing · NAICS 337110

1inspections
9citation items
$1,920current penalties
May 15, 2024last inspection

OSHA inspectors have visited Blue Ridge Cabinetry, Inc. in North Carolina one time.

It opened on May 15, 2024 as a planned inspection, in Forest City.

In all, OSHA issued 9 citation items: 5 serious and 4 other-than-serious.

The proposed penalties came to $2,750; today they stand at $1,920, 30% less.

The rule cited most here is 1910.107 (spray painting and finishing), 3 times.

Among manufacturing employers, the typical cited inspection since 2015 ends with a $3,600 penalty. Blue Ridge Cabinetry, Inc. averages $1,920 across 1 cited inspection.

Blue Ridge Cabinetry, Inc.: OSHA citation items per year, 2024 to 2024
Citation items per year, by inspection date.

North Carolina · latest 90 days of OSHA records

234employers cited

Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in North Carolina

Checking a subcontractor, a client or your own company? Watch Blue Ridge Cabinetry, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 347486250 OPENED MAY 15, 2024Closed

Planned · Complete · Health · 10 employees at the site · Closed Aug 7, 2025

551 Harris Henrietta Rd., Forest City, NC 28043 · Wood Kitchen Cabinet and Countertop Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.107(b)(5)(iv) · Spray painting and finishing
Serious$750$520Jul 18, 2024Final
Citation 1, item 1b
29 CFR 1910.107(b)(10) · Spray painting and finishing
Serious$0$0Jul 18, 2024Final
Citation 1, item 1c
29 CFR 1910.107(b)(5)(i) · Spray painting and finishing
Serious$0$0Jul 18, 2024Final
Citation 1, item 2
29 CFR 1910.213(d)(1) · Woodworking machinery
Serious$1,000$700Jul 18, 2024Final
Citation 1, item 3
29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods
Serious$1,000$700Jul 18, 2024Final
Citation 2, item 1a
29 CFR 1910.157(e)(2) · Portable fire extinguishers
Other-than-serious$0$0Jul 18, 2024Final
Citation 2, item 1b
29 CFR 1910.157(e)(3) · Portable fire extinguishers
Other-than-serious$0$0Jul 18, 2024Final
Citation 2, item 2a
29 CFR 1910.1200(e)(1) · Hazard communication
Other-than-serious$0$0Jul 18, 2024Final
Citation 2, item 2b
29 CFR 1910.1200(f)(6)(ii) · Hazard communication
Other-than-serious$0$0Jul 18, 2024Final

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1910.107 · Spray painting and finishing

29 CFR 1910.107(b)(10)

(10) Illumination. When spraying areas are illuminated through glass panels or other transparent materials, only fixed lighting units shall be used as a source of illumination. Panels shall effectively isolate the spraying area from the area in which the lighting unit is located, and shall be of a noncombustible material of such a nature or so protected that breakage will be unlikely. Panels shall be so arranged that normal accumulations of residue on the exposed surface of the panel will not be raised to a dangerous temperature by radiation or conduction from the source of illumination.

29 CFR 1910.107(b)(5)(i)

(i) The spraying operations except electrostatic spraying operations shall be so designed, installed and maintained that the average air velocity over the open face of the booth (or booth cross section during spraying operations) shall be not less than 100 linear feet per minute. Electrostatic spraying operations may be conducted with an air velocity over the open face of the booth of not less than 60 linear feet per minute, or more, depending on the volume of the finishing material being applied and its flammability and explosion characteristics. Visible gauges or audible alarm or pressure activated devices shall be installed to indicate or insure that the required air velocity is maintained. Filter rolls shall be inspected to insure proper replacement of filter media.

29 CFR 1910.107(b)(5)(iv)

(iv) Space within the spray booth on the downstream and upstream sides of filters shall be protected with approved automatic sprinklers.

29 CFR 1910.1200 · Hazard communication

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.213 · Woodworking machinery

29 CFR 1910.305 · Electrical wiring methods