Inspection 344618236 OPENED FEB 7, 2020Closed
175 Main Street, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
Canton, North Carolina · Paper (except Newsprint) Mills · NAICS 322121
OSHA has inspected Blue Ridge Paper Products LLC 19 times in North Carolina since 1999.
The latest one began on Feb 7, 2020 after a complaint, in Canton.
Those inspections ended with 131 citation items: 76 serious, 1 repeat and 54 other-than-serious.
Penalties were first proposed at $86,804 and now stand at $32,645, 62% lower after settlements or reviews.
Electrical wiring methods comes up most often in these citations: 16 items under 1910.305.
How that compares: the median penalty per cited inspection for manufacturing employers since 2015 is $4,500, and Blue Ridge Paper Products LLC averages $3,767 (3 cited inspections).
1 inspection on this page followed a fatal incident.
North Carolina · latest 90 days of OSHA records
226employers cited
Get notified the morning OSHA posts each new citation in North Carolina: the employer, the site address, the rules broken and the penalty.
See who gets cited nextLatest cited in North Carolina
Checking a subcontractor, a client or your own company? Watch Blue Ridge Paper Products LLC and get notified the morning OSHA posts a new citation for it.
Watch this company175 Main Street, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
175 Main Street, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.261(l)(9)(i) · Pulp, paper, and paperboard mills |
Serious | $7,000 | $5,000 | Feb 1, 2019 | Final |
175 Main Street, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
7291 Old Clyde Road, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.120(q)(1) · Hazardous waste operations and emergency response |
Serious | $7,000 | $5,000 | Nov 28, 2018 | Final |
7291 Old Clyde Road, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.26(a) · Dockboards |
Serious | $975 | $650 | Feb 9, 2018 | Final |
| Citation 1, item 1b 29 CFR 1910.26(e) · Dockboards |
Serious | $0 | $0 | Feb 9, 2018 | Final |
| Citation 1, item 2 29 CFR 1910.178(m)(6) · Forklifts and other powered industrial trucks |
Serious | $975 | $650 | Feb 9, 2018 | Final |
175 Main Street, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
175 Main Street, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
Incident on Dec 27, 2008: Forklift driver fractures neck transporting oversized load
On December 27, 2008, a forklift driver was transporting an oversized pallet. An unspecified accident occurred, and he fractured his neck. Hospitalization was n ot necessary.
No citations from this inspection.
1329 Howell Mill Road, Waynesville, NC 28786 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.212(a)(1) · Machine guarding |
Repeat | $6,300 | $2,520 | Jan 26, 2009 | Closed |
175 Main Street, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $500 | $250 | Nov 6, 2007 | Closed |
| Citation 1, item 2 29 CFR 1910.106(d)(7)(iii) · Flammable liquids |
Other-than-serious | $700 | $0 | Nov 6, 2007 | Closed |
| Citation 1, item 3a 29 CFR 1910.184(i)(9)(iii) · Slings |
Serious | $1,000 | $1,000 | Nov 6, 2007 | Closed |
| Citation 1, item 3b 29 CFR 1910.184(d) · Slings |
Serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 1, item 3c 29 CFR 1910.184(i)(1) · Slings |
Serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 1, item 4a 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $1,000 | $500 | Nov 6, 2007 | Closed |
| Citation 1, item 4b 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 1, item 5a 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $1,000 | $500 | Nov 6, 2007 | Closed |
| Citation 1, item 5b 29 CFR 1910.215(a)(4) · Grinders and abrasive wheels |
Serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 1, item 6a 29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts |
Serious | $2,000 | $1,000 | Nov 6, 2007 | Closed |
| Citation 1, item 6b 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 1, item 7 29 CFR 1910.303(b)(1) · Electrical equipment, general requirements |
Serious | $1,400 | $700 | Nov 6, 2007 | Closed |
| Citation 1, item 8a 29 CFR 1910.304(g)(5) · Grounding and circuit protection |
Serious | $700 | $350 | Nov 6, 2007 | Closed |
| Citation 1, item 8b 29 CFR 1910.304(g)(6)(vic)(1) · Grounding and circuit protection |
Serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 1, item 9a 29 CFR 1910.305(d) · Electrical wiring methods |
Serious | $700 | $350 | Nov 6, 2007 | Closed |
| Citation 1, item 9b 29 CFR 1910.305(b)(1)(ii) · Electrical wiring methods |
Serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 1, item 9c 29 CFR 1910.305(b)(2)(i) · Electrical wiring methods |
Serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 2, item 1 29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 2, item 2 29 CFR 1910.26(c)(2)(vii) · Portable metal ladders |
Other-than-serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 2, item 3 29 CFR 1910.37(b)(6) · Exit routes |
Other-than-serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 2, item 6 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 2, item 7 29 CFR 1910.303(f)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 2, item 8 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Nov 6, 2007 | Closed |
| Citation 2, item 9 29 CFR 1910.305(g)(1)(iva) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Nov 6, 2007 | Closed |
175 Main Street, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.253(b)(4)(iii) · Gas welding and cutting |
Serious | $875 | $438 | Nov 16, 2007 | Closed |
| Citation 1, item 2 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $625 | $312 | Nov 16, 2007 | Closed |
| Citation 1, item 3 29 CFR 1910.242(b) · Hand and power tools |
Serious | $625 | $312 | Nov 16, 2007 | Closed |
| Citation 2, item 3 29 CFR 1910.1030(h)(5)(i) · Bloodborne pathogens |
Other-than-serious | $0 | $0 | Nov 16, 2007 | Closed |
| Citation 2, item 4 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Nov 16, 2007 | Closed |
1329 Howell Mill Road, Waynesville, NC 28786 · Paper Bag and Coated and Treated Paper Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $625 | $312 | Jan 23, 2007 | Closed |
| Citation 2, item 1 29 CFR 1910.23(d)(1)(iii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Jan 23, 2007 | Closed |
| Citation 2, item 2 29 CFR 1910.157(c)(1) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jan 23, 2007 | Closed |
| Citation 2, item 3 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 23, 2007 | Closed |
| Citation 2, item 4 29 CFR 1910.305(g)(1)(iiia) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 23, 2007 | Closed |
| Citation 2, item 5 29 CFR 1910.334(a)(2)(i) · Using electrical equipment |
Other-than-serious | $0 | $0 | Jan 23, 2007 | Closed |
1329 Howell Mill Road, Waynesville, NC 28786 · Paper Bag and Coated and Treated Paper Manufacturing · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.184(i)(9)(iii) · Slings |
Other-than-serious | $1,250 | $0 | Jan 19, 2007 | Closed |
| Citation 1, item 1b 29 CFR 1910.184(i)(1) · Slings |
Serious | $0 | $0 | Jan 19, 2007 | Closed |
| Citation 1, item 2 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $875 | $875 | Jan 19, 2007 | Closed |
| Citation 1, item 3 29 CFR 1910.305(j)(2)(ii) · Electrical wiring methods |
Serious | $875 | $875 | Jan 19, 2007 | Closed |
| Citation 2, item 1 29 CFR 1910.37(b)(6) · Exit routes |
Other-than-serious | $0 | $0 | Jan 19, 2007 | Closed |
| Citation 2, item 2 29 CFR 1910.134(e)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Jan 19, 2007 | Closed |
| Citation 2, item 3 29 CFR 1910.134(f)(1) · Respiratory protection |
Other-than-serious | $0 | $0 | Jan 19, 2007 | Closed |
| Citation 2, item 4 29 CFR 1910.134(g)(1)(ia) · Respiratory protection |
Other-than-serious | $0 | $0 | Jan 19, 2007 | Closed |
| Citation 2, item 5 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jan 19, 2007 | Closed |
| Citation 2, item 6 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jan 19, 2007 | Closed |
175 Main Street, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
175 Main Street, Canton, NC 28716 · Paper (except Newsprint) Mills · OSHA's record · Phone and website on Google Maps
Incident on Jul 27, 2004 (fatal): Employee dies after fall from machine
On July 27, 2004, Employee #1 was working to free a jammed roller in a paper mac hine. He fell approximately 3 to 4 ft and struck his head on a metal piece on th e machine. Employee #1 was taken to Memorial Mission Hospital in Asheville, wher e he died on August 1, 2004. NOTE: event date is the date of death instead of th e incident date
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.147(c)(4)(i) · Lockout/tagout |
Serious | $2,275 | $2,275 | Aug 27, 2004 | Final |
175 Main Street, Canton, NC 28716 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 | Serious | $15,750 | $1,575 | Jun 12, 2002 | Final |
| Citation 2, item 1 | Serious | $963 | $562 | Jun 12, 2002 | Closed |
| Citation 2, item 2 | Other-than-serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 3 | Serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 5a | Serious | $1,925 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 5b 29 CFR 1910.179(k)(1)(i) · Overhead and gantry cranes |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 6 | Serious | $688 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 7a | Serious | $688 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 7b 29 CFR 1910.179(b)(5) · Overhead and gantry cranes |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 8 29 CFR 1910.23(a)(1) · Guarding floor and wall openings and holes |
Serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 9a 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 9b 29 CFR 1910.23(c)(1) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 9c 29 CFR 1910.23(a)(8) · Guarding floor and wall openings and holes |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 9d 29 CFR 1910.28(a)(1) · Safety requirements for scaffolding |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 10a 29 CFR 1910.37(f)(1) · Exit routes |
Serious | $688 | $516 | Jun 12, 2002 | Closed |
| Citation 2, item 10c 29 CFR 1910.37(q)(1) · Exit routes |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 12 29 CFR 1910.137(b)(2)(xii) · Electrical protective equipment |
Serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 13 29 CFR 1910.146(k)(3)(i) · Permit-required confined spaces |
Serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 14a 29 CFR 1910.147(e)(3) · Lockout/tagout |
Other-than-serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 15 29 CFR 1910.151(c) · First aid and eyewash |
Serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 16 29 CFR 1910.179(l)(3)(i) · Overhead and gantry cranes |
Serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 17a 29 CFR 1910.184(c)(1) · Slings |
Serious | $688 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 17b 29 CFR 1910.184(i)(9)(iii) · Slings |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 18 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 19 29 CFR 1910.212(a)(1) · Machine guarding |
Serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 20 29 CFR 1910.212(a)(3)(ii) · Machine guarding |
Serious | $688 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 21 29 CFR 1910.212(a)(5) · Machine guarding |
Serious | $688 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 22 29 CFR 1910.213(h)(4) · Woodworking machinery |
Serious | $413 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 23a 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $688 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 23b 29 CFR 1910.215(b)(9) · Grinders and abrasive wheels |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 23c 29 CFR 1910.243(c)(1) · Guarding of portable powered tools |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 24 29 CFR 1910.219(c)(2)(i) · Belts, pulleys and power-transmission parts |
Serious | $688 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 25a 29 CFR 1910.219(d)(1) · Belts, pulleys and power-transmission parts |
Serious | $688 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 25b 29 CFR 1910.219(e)(1)(i) · Belts, pulleys and power-transmission parts |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 26 29 CFR 1910.242(b) · Hand and power tools |
Serious | $413 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 27 29 CFR 1910.303(b)(2) · Electrical equipment, general requirements |
Serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 28a 29 CFR 1910.303(g)(2)(i) · Electrical equipment, general requirements |
Serious | $963 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 28b 29 CFR 1910.303(f) · Electrical equipment, general requirements |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 28c 29 CFR 1910.303(h)(2) · Electrical equipment, general requirements |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 29a 29 CFR 1910.304(f)(4) · Grounding and circuit protection |
Serious | $963 | $620 | Jun 12, 2002 | Closed |
| Citation 2, item 29b 29 CFR 1910.334(a)(3)(iii) · Using electrical equipment |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 30a 29 CFR 1910.305(b)(1) · Electrical wiring methods |
Serious | $963 | $963 | Jun 12, 2002 | Closed |
| Citation 2, item 30b 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 31 29 CFR 1910.305(d) · Electrical wiring methods |
Serious | $1,925 | $1,925 | Jun 12, 2002 | Closed |
| Citation 2, item 32a 29 CFR 1910.305(g)(2)(ii) · Electrical wiring methods |
Serious | $688 | $688 | Jun 12, 2002 | Closed |
| Citation 2, item 32b 29 CFR 1910.305(g)(2)(iii) · Electrical wiring methods |
Serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 2, item 33 29 CFR 1910.307(b) · Hazardous (classified) locations |
Serious | $963 | $963 | Jun 12, 2002 | Closed |
| Citation 3, item 1 29 CFR 1910.22(a)(1) · General requirements |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 2 29 CFR 1910.22(d)(1) · General requirements |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 3 29 CFR 1910.23(d)(1)(ii) · Guarding floor and wall openings and holes |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 4 29 CFR 1910.36(d)(1) · Exit route design |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 5 29 CFR 1910.37(f)(6) · Exit routes |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 6 29 CFR 1910.106(d)(3)(ii) · Flammable liquids |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 7 29 CFR 1910.157(c)(4) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 8 29 CFR 1910.157(c)(4) · Portable fire extinguishers |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 9 29 CFR 1910.212(b) · Machine guarding |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 10 29 CFR 1910.303(g)(1)(ii) · Electrical equipment, general requirements |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 11 29 CFR 1910.305(g)(1)(iiia) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 12 29 CFR 1910.305(g)(1)(iiib) · Electrical wiring methods |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
| Citation 3, item 13 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | Jun 12, 2002 | Closed |
175 Main Street, Canton, NC 28716 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.119(f)(1)(ic) · Process safety management |
Other-than-serious | $963 | $0 | May 22, 2002 | Closed |
| Citation 1, item 1b 29 CFR 1910.119(f)(1)(id) · Process safety management |
Other-than-serious | $0 | $0 | May 22, 2002 | Closed |
| Citation 1, item 1c 29 CFR 1910.119(f)(1)(ie) · Process safety management |
Other-than-serious | $0 | $0 | May 22, 2002 | Closed |
| Citation 1, item 1d 29 CFR 1910.119(f)(1)(iia) · Process safety management |
Other-than-serious | $0 | $0 | May 22, 2002 | Closed |
| Citation 1, item 1e 29 CFR 1910.119(f)(1)(iib) · Process safety management |
Other-than-serious | $0 | $0 | May 22, 2002 | Closed |
| Citation 1, item 2a 29 CFR 1910.119(j)(2) · Process safety management |
Serious | $963 | $963 | May 22, 2002 | Closed |
| Citation 1, item 2b 29 CFR 1910.119(j)(3) · Process safety management |
Serious | $0 | $0 | May 22, 2002 | Closed |
| Citation 1, item 3 29 CFR 1910.119(l)(2)(i) · Process safety management |
Other-than-serious | $963 | $0 | May 22, 2002 | Closed |
175 Main Street, Canton, NC 28716 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1 29 CFR 1910.95(j)(1) · Noise |
Other-than-serious | $0 | $0 | May 31, 2002 | Closed |
| Citation 1, item 2 29 CFR 1910.132(a) · Personal protective equipment, general requirements |
Other-than-serious | $0 | $0 | May 31, 2002 | Closed |
| Citation 1, item 3a 29 CFR 1910.134(h)(2)(i) · Respiratory protection |
Other-than-serious | $0 | $0 | May 31, 2002 | Closed |
| Citation 1, item 3b 29 CFR 1910.134(h)(3)(ia) · Respiratory protection |
Other-than-serious | $0 | $0 | May 31, 2002 | Closed |
| Citation 1, item 4 29 CFR 1910.305(b)(2) · Electrical wiring methods |
Other-than-serious | $0 | $0 | May 31, 2002 | Closed |
| Citation 1, item 5 29 CFR 1910.1001(j)(4)(ii) · Asbestos in general industry |
Other-than-serious | $0 | $0 | May 31, 2002 | Closed |
| Citation 1, item 6a 29 CFR 1910.1200(f)(5)(i) · Hazard communication |
Other-than-serious | $0 | $0 | May 31, 2002 | Closed |
| Citation 1, item 6b 29 CFR 1910.1200(f)(5)(ii) · Hazard communication |
Other-than-serious | $0 | $0 | May 31, 2002 | Closed |
| Citation 1, item 6c 29 CFR 1910.1200(h)(1) · Hazard communication |
Other-than-serious | $0 | $0 | May 31, 2002 | Closed |
175 Main Street, Canton, NC 28716 · OSHA's record · Phone and website on Google Maps
No citations from this inspection.
175 Main Street, Canton, NC 28716 · OSHA's record · Phone and website on Google Maps
| Citation and rule | Type | Proposed | Current | Issued | Status |
|---|---|---|---|---|---|
| Citation 1, item 1a 29 CFR 1910.119(j)(4)(iii) · Process safety management |
Other-than-serious | $963 | $0 | Feb 24, 2000 | Closed |
| Citation 1, item 1b 29 CFR 1910.1200(h)(3)(iii) · Hazard communication |
Other-than-serious | $0 | $0 | Feb 24, 2000 | Closed |
Current text from the Code of Federal Regulations. Some citations were issued under older wording.
29 CFR 1910.106(d)(3)(ii)
(ii) Fire resistance. Storage cabinets shall be designed and constructed to limit the internal temperature to not more than 325 °F. when subjected to a 10-minute fire test using the standard time-temperature curve as set forth in Standard Methods of Fire Tests of Building Construction and Materials, NFPA 251-1969, which is incorporated by reference as specified in § 1910.6. All joints and seams shall remain tight and the door shall remain securely closed during the fire test. Cabinets shall be labeled in conspicuous lettering, “Flammable—Keep Fire Away.”
29 CFR 1910.106(d)(7)(iii)
(iii) Open flames and smoking. Open flames and smoking shall not be permitted in flammable liquid storage areas.
Alert subscribers get notified of each newly cited employer in North Carolina the morning it is posted. See the alert plans.
Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.