OSHA SearchOSHA records by employer

Bob Murphy, Inc.: OSHA inspections and violations

Vestal, New York · Fabricated Structural Metal Manufacturing · NAICS 332312

4inspections
14citation items
$6,975current penalties
Nov 20, 2015last inspection

Bob Murphy, Inc. has 4 OSHA inspections on record in New York, the first in 1981.

OSHA's last visit started on Nov 20, 2015 as a planned inspection, in Vestal.

Across those inspections OSHA issued 14 citation items: 13 serious and 1 other-than-serious.

OSHA proposed $9,775 in penalties. After settlements and reviews the total is $6,975, down 29%.

Most often, OSHA cited 1910.212, machine guarding (5 items).

For context, across all manufacturing employers the median penalty per cited inspection since 2015 is $3,600. Bob Murphy, Inc. averages $4,800 over 1 cited inspection in that time.

Bob Murphy, Inc.: OSHA citation items per year, 1981 to 2015
Citation items per year, by inspection date.

New York · latest 90 days of OSHA records

359employers cited

2 of them in the same industry

Get notified the morning OSHA posts each new citation in New York: the employer, the site address, the rules broken and the penalty.

See who gets cited next

Latest cited in New York

Checking a subcontractor, a client or your own company? Watch Bob Murphy, Inc. and get notified the morning OSHA posts a new citation for it.

Watch this company

Inspection history

Inspection 341074052 OPENED NOV 20, 2015Closed

Planned · Partial · Safety · 16 employees at the site · Closed Oct 20, 2017

3127 Vestal Road, Vestal, NY 13850 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1a
29 CFR 1910.147(c)(4)(i) · Lockout/tagout
Serious$2,000$1,500Dec 17, 2015Final
Citation 1, item 1b
29 CFR 1910.147(c)(6)(i) · Lockout/tagout
Serious$0$0Dec 17, 2015Final
Citation 1, item 2
29 CFR 1910.157(g)(2) · Portable fire extinguishers
Serious$1,200$900Dec 17, 2015Final
Citation 1, item 3a
29 CFR 1910.212(a)(1) · Machine guarding
Serious$1,600$1,200Dec 17, 2015Final
Citation 1, item 3b
29 CFR 1910.212(a)(5) · Machine guarding
Serious$0$0Dec 17, 2015Final
Citation 1, item 4
29 CFR 1910.178(l)(4)(iii) · Forklifts and other powered industrial trucks
Serious$1,600$1,200Dec 17, 2015Final

Inspection 312374838 OPENED MAR 24, 2010Closed

Planned · Partial · Safety · 16 employees at the site · Closed Feb 16, 2011

3127 Old Vestal Road, Vestal, NY 13850 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.212(a)(1) · Machine guarding
Serious$750$500Apr 6, 2010Closed
Citation 1, item 2
29 CFR 1910.212(a)(3)(ii) · Machine guarding
Serious$750$500Apr 6, 2010Closed
Citation 1, item 3a
29 CFR 1910.305(a)(2)(ix) · Electrical wiring methods
Serious$750$500Apr 6, 2010Closed
Citation 1, item 3b
29 CFR 1910.305(g)(1)(iva) · Electrical wiring methods
Serious$0$0Apr 6, 2010Closed

Inspection 309376960 OPENED NOV 2, 2005Closed

Planned · Partial · Safety · 16 employees at the site · Closed Dec 14, 2005

3127 Old Vestal Road, Vestal, NY 13850 · Fabricated Structural Metal Manufacturing · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1910.37(a)(2) · Exit routes
Serious$375$225Nov 15, 2005Closed
Citation 1, item 2
29 CFR 1910.212(a)(1) · Machine guarding
Serious$375$225Nov 15, 2005Closed
Citation 1, item 3
29 CFR 1910.217(c)(1)(i) · Mechanical power presses
Serious$375$225Nov 15, 2005Closed

Inspection 11995875 OPENED SEP 30, 1981Closed

Accident · Complete · Safety · 1 employee at the site · Closed Oct 30, 1981

Fenner Road, Ithaca, NY 14882 · OSHA's record · Phone and website on Google Maps

Citation and ruleTypeProposedCurrentIssuedStatus
Citation 1, item 1
29 CFR 1904.8 · Recording criteria for needlestick and sharps injuries
Other-than-serious$0$0Oct 7, 1981Closed

The rules behind these citations

Current text from the Code of Federal Regulations. Some citations were issued under older wording.

29 CFR 1904.8 · Recording criteria for needlestick and sharps injuries

29 CFR 1910.147 · Lockout/tagout

29 CFR 1910.147(c)(4)(i)

(4) Energy control procedure. (i) Procedures shall be developed, documented and utilized for the control of potentially hazardous energy when employees are engaged in the activities covered by this section.

29 CFR 1910.147(c)(6)(i)

(6) Periodic inspection. (i) The employer shall conduct a periodic inspection of the energy control procedure at least annually to ensure that the procedure and the requirements of this standard are being followed.

29 CFR 1910.157 · Portable fire extinguishers

29 CFR 1910.157(g)(2)

(2) The employer shall provide the education required in paragraph (g)(1) of this section upon initial employment and at least annually thereafter.

29 CFR 1910.178 · Forklifts and other powered industrial trucks

29 CFR 1910.212 · Machine guarding

29 CFR 1910.217 · Mechanical power presses

29 CFR 1910.305 · Electrical wiring methods

29 CFR 1910.37 · Exit routes

Other fabricated structural metal manufacturing employers in New York

Alert subscribers get notified of each newly cited employer in New York the morning it is posted. See the alert plans.

Source: U.S. Department of Labor, OSHA enforcement data. A citation is OSHA's allegation; employers can contest it, and the status column shows where each item stands. Something wrong on this page? Tell us.